3.6~35kV XLPE Insulated Power Cable
Next

3.6i½z35kV XLPE Insulated Power Cable

5000 / Kilometer

|

1 Kilometer Minimum Order

بلد:

China

نموذج رقم:

YJV, YJV22

سعر فوب:

5000 / Kilometer أحصل على آخر سعر

الموقع:

Foshan,China

سعر الحد الأدنى للطلب:

5000 per Kilometer

الحد الأدني للطلب:

1 Kilometer

تفاصيل التغليف:

Export Wooden Drum

موعد التسليم:

As Quantity

القدرة على التوريد:

20 Kilometer per Day

نوع الدفع:

L/C, T/T

مجموعة المنتج :

-

الاتصال الآن
عضو مجاني

الشخص الذي يمكن الاتصال به Mr. Yan

Rm 1510, B Block Tianan Cyber Park Office Building No.1 Jianping Road Guicheng Town,Nanhai Distric, Foshan

الاتصال الآن

الوصف

3.6/6(7.2)kV XLPE insulated power cable                                                                 6/6(7.2)kV & 6/*0(*2)kV XLPE insulated power cable
8.7/*0(*2)kV & 8.7/*5(*7.5)kV XLPE insulated power cable
*2/*0(*4)kV XLPEinsulated power cable
8.7/*0(*2)kV XLPE insulated power cable
*8/*0(*6)kV XLPE insulated power cable
*1/*5(*0.5)kV XLPE insulated power cable                                                                         *6/*5(*0.5)kV XLPE insulated power cable 


The cable meets the standard requirements of GB/T*********2 or IEC*********7.It is suitable

to be installed in the power line with rated voltage from U0/U(Um) of 3.6/6(7.2)KVto *6/*5(*0.5)KV.

Using properties
Earth fault permissible duration
The operating systems are divided into three categories available for selecting cable

 

Category A:When any phase is earthed, the cable can be departed from the system within 1 minute.
Category B:The earth fault duration each time does not exceed one hour, the accumulated time shall not exceed **5 hours each year.
Category C: Excluded categories from A and B.                        

The maximum rated temperature
The maximum operating temperature of cores shall not exceed *0℃ when the cable is used for long period. The temperature of cores shall not exceed **0℃ at short circuit for 5 seconds.

 

Installation requirement
The installation of cables is not limited by the difference of level along the route. The ambient temperature should not be below 0℃ during installation. The permissible bending radius for cable shall not be less than *0 times of the cable diameter. The single cable shall be without amour or with steel wire amour when it is electrified with alternating current and shall not be laid in magnetic ducts.

بلد: China
نموذج رقم: YJV, YJV22
سعر فوب: 5000 / Kilometer أحصل على آخر سعر
الموقع: Foshan,China
سعر الحد الأدنى للطلب: 5000 per Kilometer
الحد الأدني للطلب: 1 Kilometer
تفاصيل التغليف: Export Wooden Drum
موعد التسليم: As Quantity
القدرة على التوريد: 20 Kilometer per Day
نوع الدفع: L/C, T/T
مجموعة المنتج : -

Send a direct inquiry to this supplier

إلى:

Mr. Yan < Guangdong Win-Win Cables(mfg)Co., Ltd >

أريد أن أعرف: