سعر فوب
أحصل على آخر سعر|
- Minimum Order
بلد:
China
نموذج رقم:
-
سعر فوب:
الموقع:
-
سعر الحد الأدنى للطلب:
-
الحد الأدني للطلب:
-
تفاصيل التغليف:
-
موعد التسليم:
-
القدرة على التوريد:
-
نوع الدفع:
-
مجموعة المنتج :
الشخص الذي يمكن الاتصال به Robin
No. 30 XinFeng Road,Potoubei Village,Ailian Town, Shenzhen, Guangdong
Three battery type option:
Gel,Sealed,Flooded
Settable:
Float charging voltage;
Low voltage reconnect voltage;
Low voltage discounnect voltage;
Load start-up delay;
Optical sensitivity.
Four load working modes:
Pure lighting control
lighting control &timing control,
hand operation
debug mode.
Features:
*2/*4V automatic recognition
·High efficient Series PWM charging, increase the battery lifetime and improve the solar system performance.
·Use MOSFET as electronic switch, without any mechanical switch
·Widely used, automatically recognize day/night.
·Digital LED menu, only one key solve all setting simply
·Intelligent timer function with ***5 hours option
·Unique dual timer function, enhance the flexibility of street light system.
·Gel, Sealed and Flooded battery type option.
·Adopt temperature compensation, correct the charging and discharging parameters automatically and improve the battery lifetime.
·Electronic protection: Overheating, over charging, over discharging,
overload, and short circuit.
·Reverse protection: any combination of solar module and battery.
Settings
. Load Control Settings
1. Dusk to Dawn
When solar module voltage goes below the point of NTTV (Night Time Threshold Voltage) at sunset, the controller will recognize the starting voltage and turn on the load after *0 minutes delay. When solar module voltage goes above point of DTTV (Day Time Threshold Voltage), the solar controller will recognize the starting voltage and turn off the load after *0 minutes delay.
2. Light ON + Timer
When solar module voltage goes below the point of NTTV (Night Time Threshold Voltage) at sunset; the solar controller will recognize the starting voltage and turn on the load after *0 minutes delay. The load will be on for several hours which users set through LED digital tube. The controller has dual timer function. Please refer to table **5 ―Load Work Mode Setting‖.
3. Test mode
This mode is the same as Dusk to Dawn. But there is no *0 minutes delay when controller recognizes the starting voltage. When below the starting voltage, the controller will turn on the load, if higher, it will turn off load.
The test mode makes it easy to check the system installation.
4. ON/OFF mode
This mode is to turn ON and OFF the load by manual.
بلد: | China |
نموذج رقم: | - |
سعر فوب: | أحصل على آخر سعر |
الموقع: | - |
سعر الحد الأدنى للطلب: | - |
الحد الأدني للطلب: | - |
تفاصيل التغليف: | - |
موعد التسليم: | - |
القدرة على التوريد: | - |
نوع الدفع: | - |
مجموعة المنتج : | 2014 NEW |