يبدو أنك لست عضوًا في TradeKey.com بعد. اشترك الآن للتواصل مع أكثر من 7 مليون مستورد ومصدر عالميًا. انضم الآن ، مجانًا |
BOOK A CALL
Book Call On Your Favorite Time
Code
🗘

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
35kV 66kV 110kV 132kV Gas SF6  Type Current Transformer 35kV 66kV 110kV 132kV Gas SF6  Type Current Transformer 35kV 66kV 110kV 132kV Gas SF6  Type Current Transformer 35kV 66kV 110kV 132kV Gas SF6  Type Current Transformer
Next

35kV 66kV 110kV 132kV Gas SF6 Type Current Transformer

3256 ~ 12897 USD / Piece

|

1 Set Minimum Order

بلد:

China

نموذج رقم:

LVQB

سعر فوب:

3256 ~ 12897 USD / Piece أحصل على آخر سعر

الموقع:

-

سعر الحد الأدنى للطلب:

3256 per Piece

الحد الأدني للطلب:

1 Set

تفاصيل التغليف:

wooden cases

موعد التسليم:

20 days

القدرة على التوريد:

100 Set per Month

نوع الدفع:

L/C, T/T

مجموعة المنتج :

الاتصال الآن
عضو مجاني

الشخص الذي يمكن الاتصال به Mr. Leo

No. 8 Fuhua Road , Dongcheng Street , Sihui City , Guangdong Province, China, Zhaoqing, Guangdong

الاتصال الآن

مواصفات المنتج

  • Rated voltage:35kV 66kV 110kV 132kV 150kV 220kV 330kV 380kV 500kV
  • Primary current :50A~ 4000A
  • Secondary current:1A or 5A
  • Accuracy class:0.2S 0.2S 0.5S 0.5S 5P 10P PR PX TPS TPX TPY TPZ
  • Rated output :20VA~50VA
  • Insulation material:Gas SF6

الوصف

SF6 Current Transformers
Products Explanation:
Model: LVQB
Technical Parameters:

Rated voltage is *5kV up to **0kV
Highest voltage for equipment is *0.5kV up to **2kV
Rated primary current is *0A~***0A
Rated secondary current is 5A or 1A
Rated frequency is *0Hz or *0Hz
Rated output: *0VA~*0VA (If any other rated output required, we can satisfy it.)
Rated continuous thermal current Icth is 1.2In
0.*0MPa Rated operating pressure of the SF6 gas is 0.*0MPa
Minimum operating pressure of the SF6 gas is 0.*5MPa
Instrument security factor (FS) of measuring class is 5 or *0
Accuracy limit factor (ALF) of protective class is 5, *0, *5, *0, *0 or *0
Accuracy classes and their combinations: Steady accuracy classes are 0.2S, 0.2, 0.5S, 0.5, 5P, *0P, PR and PX; transient accuracy classes are TPS, TPX, TPY and TPZ. There are 1~6 pcs secondary winding(s) in a CT.
Arcing distance is**0mm
Non-effectively earthed neutral system
Main Features:
  The current transformer is SF6 gas insulation, inverted frame, with the top of T type aluminum case which there are secondary winding(s) and primary winding(s) inside. The bushing is composite materials with silicon rubber umbrellas or high strength porcelain. The secondary terminal leads which through the metal tube are connected with the secondary terminals box which at the base. There is a pressure relief device at the top of the case, when the pressure is more than 0.8MPa if the current transformer is discharge inside, the relief device will be broken to release the pressure and send alarm information. There is a SF6 density monitor fix at the base, it can indicate the SF6 pressure which inside the current transformer (its indicated value is the SF6 pressure at *0ƒ), and it will provide an information when the SF6 pressure is drop down to the minimum service pressure of the current transformer, to remind the user replenish the SF6 gas to the rated pressure.

بلد: China
نموذج رقم: LVQB
سعر فوب: 3256 ~ 12897 / Piece أحصل على آخر سعر
الموقع: -
سعر الحد الأدنى للطلب: 3256 per Piece
الحد الأدني للطلب: 1 Set
تفاصيل التغليف: wooden cases
موعد التسليم: 20 days
القدرة على التوريد: 100 Set per Month
نوع الدفع: L/C, T/T
مجموعة المنتج : high voltage current transformer

Send a direct inquiry to this supplier

إلى:

Mr. Leo < Guangdong Sihui Instrument Transformr Works Co., Ltd. >

أريد أن أعرف: