يبدو أنك لست عضوًا في TradeKey.com بعد. اشترك الآن للتواصل مع أكثر من 7 مليون مستورد ومصدر عالميًا.
انضم الآن ، مجانًا |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
Acrel AIM-M100 hospital insulation monitor in surgical rooms with IEC Acrel AIM-M100 hospital insulation monitor in surgical rooms with IEC Acrel AIM-M100 hospital insulation monitor in surgical rooms with IEC Acrel AIM-M100 hospital insulation monitor in surgical rooms with IEC Acrel AIM-M100 hospital insulation monitor in surgical rooms with IEC
Next

Acrel AIM-M100 hospital insulation monitor in surgical rooms with IEC

1617 ~ 2310 / Piece

|

1 Piece Minimum Order

بلد:

China

نموذج رقم:

AIM-M100

سعر فوب:

1617 ~ 2310 / Piece أحصل على آخر سعر

الموقع:

Jiangsu Province, China

سعر الحد الأدنى للطلب:

1617 per Piece

الحد الأدني للطلب:

1 Piece

تفاصيل التغليف:

Paper carton with bubble film

موعد التسليم:

7-15 days

القدرة على التوريد:

50000 Piece per Year

نوع الدفع:

T/T

مجموعة المنتج :

الاتصال الآن
عضو مجاني

الشخص الذي يمكن الاتصال به Ms. Jonnie

Yulv Road, Shanghai, Shanghai

الاتصال الآن

مواصفات المنتج

  • Voltage:AC220V
  • Power consumption:8VA
  • Thermistor:PT100
  • Alarm value range:5~50A
  • Measuring temperature range:-50~+200
  • Alarm output:2 relay output

الوصف

AIM-M100 Medical Insulation Monitor Device

Technical Parameter

 
AUX Power Voltage AC220V±10% Temperature monitoring Thermal resistor 2 Pt100
Power consumption ≤8VA Measuring range -50~+200℃
Insulation monitoring Resistance measuring range 10~999kΩ Alarm value range 0~+200℃
Response value 50~999kΩ Alarm
output
Output mode 2 Relays
Relative uncertainty ±10% Contact rating AC 250V/3A
DC 30V/3A
Response time ≤3s Environment Operating temperature -10~+55℃
Permissible system leakage capacitance Ce 5uF Transport temperature -25~+70℃
Measuring voltage Um ≤12V Storage temperature -25~+70℃
Measuring current Im ≤50uA Relative humidity 5%-95%,No condensation
Impedance Zi 200kΩ Altitude 2500m
InternalDC resistance Ri 240kΩ IP degree IP30
Permissible extraneous DC voltage Ufg DC280V Rated impulse voltage / pollution degree 4KV/â…¢
Load current monitoring Measuring Value 2.1~50A EMC IEC 61326-2-4
Alarm Value 5~50A Communication RS485(Modbus-RTU)
Measuring accuracy ±5%
 
 
Dimension
 
image image

Terminal Diagram
 
image

Application
image

بلد: China
نموذج رقم: AIM-M100
سعر فوب: 1617 ~ 2310 / Piece أحصل على آخر سعر
الموقع: Jiangsu Province, China
سعر الحد الأدنى للطلب: 1617 per Piece
الحد الأدني للطلب: 1 Piece
تفاصيل التغليف: Paper carton with bubble film
موعد التسليم: 7-15 days
القدرة على التوريد: 50000 Piece per Year
نوع الدفع: T/T
مجموعة المنتج : Medical IMD

منتجات ذات العلاق Acrel Co., Ltd.

Send a direct inquiry to this supplier

إلى:

Ms. Jonnie < Acrel Co., Ltd. >

أريد أن أعرف: