يبدو أنك لست عضوًا في TradeKey.com بعد. اشترك الآن للتواصل مع أكثر من 7 مليون مستورد ومصدر عالميًا. انضم الآن ، مجانًا |
BOOK A CALL
Book Call On Your Favorite Time
Code
🗘

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
AT500 SERIES - 0.75kw~600kw frequency inverter close loop vector control
Next

AT500 SERIES - 0.75kw~600kw frequency inverter close loop vector control

|

1 Piece Minimum Order

بلد:

China

نموذج رقم:

-

سعر فوب:

أحصل على آخر سعر

الموقع:

China

سعر الحد الأدنى للطلب:

-

الحد الأدني للطلب:

1 Piece

تفاصيل التغليف:

-

موعد التسليم:

-

القدرة على التوريد:

8000 Piece per Month

نوع الدفع:

T/T, L/C, Western Union, Money Gram

مجموعة المنتج :

-

الاتصال الآن
عضو مجاني

الشخص الذي يمكن الاتصال به Ms. Tiffany

Floor 7~11 Building A International Innovation Park of China Sensor Network No 200 Ling Lake Avenue, Wuxi, Jiangsu

الاتصال الآن

مواصفات المنتج

الوصف


 
1) Close-loop vector control
2) Inovance MD**0  software
3) Infineon(<*7KW)  and Mitsubishi (>*7KW ) IGBT
4) Built-in PLC ,PID , AVR function
5) Torque control can be implemented in the CLVC mode.
6) Instantaneous power off , inverter keep running
7) Timing control function
8) Auto Stand-by and Sleep Mode
9) Fixed-length control &Torque control mode
*0) RPM Monitoring Feature
*1) Optional parts :Braking unit, I/O extension card, RS**5 communication card, PROFIBUS-DP communication card, Differential PG card, OC PG card.etc.

 
►►►    Technical specification    â—„â—„â—„
 
 

Item Specification
Basic functions Maximum
frequency
**0Hz
Carrier frequency 0.5kHz~*6.0kHzï¼›Depending on the load Characteristics,and automatically adjust the carrier frequency.
Input frequency resolution Digital set:0.*1Hz
Simulation set:The highest frequency×0.**5%
Control mode V/F Control,SVC,FVC
Startup torque **0%
Speed range 1:**0(SVC) 1:***0(FVC)
Speed stability accuracy ±0.5%(SVC) ±0.*2%(FVC)
Overload capacity G type machine: **0%rated current *0s,**0%rated current 3s
P type machine: **0% rated current *0s,**0%rated current 3s
Torque boost Automatic torque boostï¼›Manual torque boost 0.1%~*0.0%
V/F curve Straight line V/F, Multi-point V/F,N-th power V/F
Ramp mode • Straight-line ramp
• S-curve ramp
Four groups of acceleration/deceleration time with the range of 0.****0.0s
DC braking DC braking frequency: 0.*0 Hz to maximum frequency
Braking time: 0.***0.0s
Braking action current value: 0.0%~**0.0%
JOG control JOG frequency range: 0.***0.*0 Hz
JOG acceleration/deceleration time: 0.****0.0s
 
Item Specification
Onboard multiple
preset speeds
It implements up to *6 speeds via the simple PLC function or combination of DI terminal states.
Onboard PID It realizes process-controlled closed loop control system easily.
Auto voltage
regulation (AVR)
It can keep constant output voltage automatically when the mains voltage changes.
Overvoltage/
Overcurrent stall control
The current and voltage are limited automatically during
the running process so as to avoid frequent tripping due to overvoltage/overcurrent.
Fast current limit function Minimize the over-current fault,and protect the normal operation of the AC drive.
Torque limit and
control
 It can limit the torque automatically and prevent frequent over current tripping during the running process.
Torque control can be implemented in the CLVC mode.
Individualized
functions
High performance Control of asynchronous motor and synchronous motor are
implemented through the high-performance current vector control technology.
Power dip ride through The load feedback energy compensates the voltage reduction so that the AC drive can continue to run for a short time.
Timing control Time range: 0.****0.0 minutes
RS**5 bus support Modbus-RTU protocol
Running
 
Running
command source
• Operation panel
• Control terminals
• Serial communication port
You can perform switch over between these sources in various ways.
Frequency source There are a total of *3 frequency sources, such as digital setting, analog voltage setting, analog current setting, pulse setting and serial communication port setting,variety of speed PLC, PID.
You can perform switch over between these sources in various ways.
Auxiliary
frequency source
There are *3 auxiliary frequency sources. It can implement
fine tuning of auxiliary frequency and frequency synthesis.
Input terminals 5 digital (DI) terminals, X5 supports up to **0 kHz high-speed pulse ;
2 analog (AI) terminals, A1 only supports **0 V voltage and A2 supports **0 V voltage or **0 mA current .
Output terminals 1 high-speed pulse output terminal (open-collector) that supports ***0 kHz square wave signal output
1 digital output (DO) terminal  2relay output terminals
2 analog output (AO) terminals that supports **0 mA
current output or **0 V voltage output.

بلد: China
نموذج رقم: -
سعر فوب: أحصل على آخر سعر
الموقع: China
سعر الحد الأدنى للطلب: -
الحد الأدني للطلب: 1 Piece
تفاصيل التغليف: -
موعد التسليم: -
القدرة على التوريد: 8000 Piece per Month
نوع الدفع: T/T, L/C, Western Union, Money Gram
مجموعة المنتج : -

منتجات ذات العلاق Skybee Electric Co., Ltd

Send a direct inquiry to this supplier

إلى:

Ms. Tiffany < Skybee Electric Co., Ltd >

أريد أن أعرف: