يبدو أنك لست عضوًا في TradeKey.com بعد. اشترك الآن للتواصل مع أكثر من 7 مليون مستورد ومصدر عالميًا.
انضم الآن ، مجانًا |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
Battery management system for HEV/ BEV/ backup power supply
Next

Battery management system for HEV/ BEV/ backup power supply

( Negotiable )

|

1 Minimum Order

بلد:

China

نموذج رقم:

EK-FT-11

سعر فوب:

( Negotiable ) أحصل على آخر سعر

الموقع:

China

سعر الحد الأدنى للطلب:

-

الحد الأدني للطلب:

1

تفاصيل التغليف:

Standard

موعد التسليم:

Within 2 weeks after receiving the payment

القدرة على التوريد:

50000

نوع الدفع:

T/T

مجموعة المنتج :

-

الاتصال الآن
عضو مجاني

الشخص الذي يمكن الاتصال به Ms. Daisy

4F,NO.28Hehuan Road, Hefei, Anhui

الاتصال الآن

الوصف


EK-FT**1 system is mainly used in the field of electric vehicles, the system is composed of EK-FT-C*1 central control module, EK-FT-M***2 data collection module, also strong electric control, insulation test, touch screen and other functional modules can be added to the system; 

NO. Names Specifications
1 Voltage Detection Maximum strings support from the voltage detector: *2 * n (n *5, total pressure ***0V)
    Voltage detection range: 0 to 5 V (other voltages can be customized)
    Voltage detection accuracy of ± 5mV
2 Temperature Detection Temperature detection maximum support 3 * n (n *5)
    Temperature sensing range of **0 ° C to **5 ° C
    Temperature measurement accuracy ± 2 ° C (**0 ° C ~ *5 ° C)
3 Current Detection Current ranges ± ***0A (Current sensor optional)
    Current measurement accuracy of ± 1%
4 BCU module relay control *-way active output interface, *-way passive output interface
    Rated load current 1.2A, peak current 4A
5 BMU module relay control *-way relay control, rated load current 1.2A peak current 4A
6 Passive equilibrium At the same time,can open *-way balance under certain conditions , and different balances are independent of each other, the maximum current **0mA
7 Balanced failure protection Effective protection of the battery safety
8 **5 conmmunications *-way **5 communication interface
9 BCU module CAN communications *-way CAN communication interface
*0 BMU module CAN communications *-way CAN communication interface
*1 Switching signal output *-way switch signal output, the maximum load current of **0mA
*2 Active signal *-way active signal , 9 ~ *6V
*3 Data Display LCD screen can be connected through the **5 BUS
    Can connect the host computer via **5 or CAN
*4 SOC estimation error <5%
 

بلد: China
نموذج رقم: EK-FT-11
سعر فوب: ( Negotiable ) أحصل على آخر سعر
الموقع: China
سعر الحد الأدنى للطلب: -
الحد الأدني للطلب: 1
تفاصيل التغليف: Standard
موعد التسليم: Within 2 weeks after receiving the payment
القدرة على التوريد: 50000
نوع الدفع: T/T
مجموعة المنتج : -

Send a direct inquiry to this supplier

إلى:

Ms. Daisy < Anhui Ligoo New Energy Technology Co., Ltd. >

أريد أن أعرف: