1. Technical Principles
Hydraulic fan, as the name suggests, it is to use water other than traditional electricity to drive the fan. In hydraulic fan cooling tower, hydraulic turbine is used to replace motor as the power source for fan. Driving force for running hydraulic turbine comes from surplus energy of the system.
Â
2. Technical Advantages
1) Visible effects, **0% energy saving of fans and motors, and the recovery period is about one and a half years.
2) Eliminate all the electrical systems, which leads to easy maintenance, low failure rate, and high safety performance.
3) Low maintenance costs.
4) Short reconstruction period, with no major change in entire circulating water system, can usually be completed within ***0 days.
5) Double water inlets reduce vibration and noise.
6) High energy utilization rate of the system surplus energy, with the total utilization rate of about *0%.
7) Push the water pump operating point to the high efficient area, so as to operate at the best conditions. Â
Â
Francis reaction mixed-flow turbine
1.Turbine volute uses a molding overall casting technology with high precision,smooth surface of the flow channel, which will help improve the efficiency of the turbine.
Â
Performance Comparison Table
Comparison Items between Traditional Cooling Tower and Water Kinetic Energy Recovery Cooling Tower | Traditional Cooling Tower | Water Kinetic Energy Recovery Cooling Tower |
 Water | It is necessary to compensate water often | It is unnecessary to compensate water often |
 Electricity | Every one hundred tons circulating water consumes **6 KWH power each hour. | No power consumption |
Operating Cost | High | Low |
Reliability | It is necessary to often carry out routine maintenance for electric  motor and reduction gear box | It is unnecessary to often carry out routine maintenance for electric  motor and reduction gear box |
Safety | It is necessary to equip with  explosion-proof motor and electric control device | It may work in any areas which require explosion-proof |
   Environmental Protection | Water drift, nose, and vibration impact on the environment | No pollution |
Cooling Effect | Good | Good |
 Water Drift Rate | Higher | Lower |
Applicability | Suitable for any circumstances which require mechanical ventilation cooling tower | Suitable for any circumstances which require mechanical ventilation cooling tower |
Mechanical Noise | Large | Little |
بلد: | China |
نموذج رقم: | 200T-5000T |
سعر فوب: | 7100 ~ 124000 / Set ( Negotiable ) أحصل على آخر سعر |
الموقع: | Hefei City, AnHui Province |
سعر الحد الأدنى للطلب: | 7100 per Set |
الحد الأدني للطلب: | 1 Set |
تفاصيل التغليف: | Exporting Wooden package or Steel package |
موعد التسليم: | within 40days after order confirmation |
القدرة على التوريد: | 30 Set per Month |
نوع الدفع: | T/T |
مجموعة المنتج : | cooling tower |