سعر فوب
أحصل على آخر سعر( Negotiable )
|1 Unit Minimum Order
بلد:
China
نموذج رقم:
HYG-2571
سعر فوب:
( Negotiable )أحصل على آخر سعر
الموقع:
-
سعر الحد الأدنى للطلب:
-
الحد الأدني للطلب:
1 Unit
تفاصيل التغليف:
1 unit/box
موعد التسليم:
within 7 days
القدرة على التوريد:
1000 Unit per Month
نوع الدفع:
Western Union, L/C, T/T
مجموعة المنتج :
الشخص الذي يمكن الاتصال به Jenny
Wuhan, Hubei
Alternative Name
Digital ground resistance tester, ground resistance
tester
Product Introduction
The instrument applies to power industry, post and
telecommunications, railway, communications, mining and other
sectors to measure the grounding resistance of the various devices
and the conductor resistance of low resistance; this instrument can
also measure soil resistivity and ground voltage.
Product Features:
1. High-strength aluminum alloy shell body, the circuit equipped
with phase locked loop and switched capacitor filter, based on
which the instrument play an effective role in shielding power
frequency and radio frequency interference.
2. DC/AC converter can transform DC current into AC low-frequency
constant current for the measurement.
3. Auxiliary grounding resistance can change in the range of 0 ~
2KΩ (RC), 0 ~ *0KΩ (RP), that will not affect measurement
results.
4. Without manual adjustment to zero, with three and a half bits
LED display, the instrument can be used for measuring the grounding
resistance, the conductor resistance of low resistance, soil
resistivity and AC ground voltage.
Technical Specifications:
1. Operating Conditions
Temperature, 0 ºC ~ **5 ºC
Relative humidity ≤ *5%
2. Measuring range and constant current value (virtual
value)
Resistance, 0 ~ 2Ω (*0mA), 2 ~ *0Ω (*0mA), *0 ~ **0Ω
(1mA)
Voltage, AC 0 ~ *0V
3. Measurement accuracy and resolution
Accuracy,0 ~ 0.2Ω ≤ ± 3% ± 1d
0.2Ω ~ **0Ω ≤ ± 1.5% ± 1d
1 ~ *0V ≤ ± 3% ± 1d
Resolution,0.**1Ω, 0.*1Ω, 0.1Ω, 0.*1V
4. Measurement errors caused by auxiliary grounding resistance and
ground voltage
Auxiliary grounding resistance RC (between C1 and
C2)
0 ~ 2Ω, 2 ~ *0Ω ≤ 1KΩ
*0 ~ **0Ω ≤ 2KΩ
RP (between P1 and P2) <*0KΩ
error ≤ ± 5%
Ground voltage (frequency virtual value) ≤
5V error ≤ ± 5%
5. Power supply and power dissipation
Maximum power dissipation≤ 2W
DC 8 × 1.5V (AA, R6) Battery
AC **0V/*0Hz
6. Dimensions and weight
Dimensions
**0mm×**0mm×**5mm
Weight ≤ 1.4kg
بلد: | China |
نموذج رقم: | HYG-2571 |
سعر فوب: | ( Negotiable ) أحصل على آخر سعر |
الموقع: | - |
سعر الحد الأدنى للطلب: | - |
الحد الأدني للطلب: | 1 Unit |
تفاصيل التغليف: | 1 unit/box |
موعد التسليم: | within 7 days |
القدرة على التوريد: | 1000 Unit per Month |
نوع الدفع: | Western Union, L/C, T/T |
مجموعة المنتج : | Insulation/Earth Resistance Tester |