Electrolyte Analyzer
Next

Electrolyte Analyzer

1 ~ 1 / Unit

|

1 Unit Minimum Order

بلد:

China

نموذج رقم:

SIRMA 2000 series

سعر فوب:

1 ~ 1 / Unit أحصل على آخر سعر

الموقع:

Shanghai

سعر الحد الأدنى للطلب:

1 per Unit

الحد الأدني للطلب:

1 Unit

تفاصيل التغليف:

Double carton box with shockproof

موعد التسليم:

10 days

القدرة على التوريد:

300 Unit per Year

نوع الدفع:

-

مجموعة المنتج :

الاتصال الآن
عضو مجاني

الشخص الذي يمكن الاتصال به Mr. Morgan

Yin Xing, Shanghai, Shanghai

الاتصال الآن

مواصفات المنتج

  • OEM service:White

الوصف

Technical Features SIRMA ***0 series

â–  Reliable Long-life Electrode

The non-lead assembled ion selective electrode is made from the imported material. It is guaranteed for *2 months. SIRMA exclusively applies silver chloride inner electrode, thoroughly preventing the risk of early failure. The special full sealing technology is used for all electrodes. For this purpose, the leakage of electrode (especially for the reference electrode easily leaked) can disappear, the reliability and service life can increase and the maintenance of electrode can be done automatically by instrument. These technologies are the important guarantee for SIRMA electrolyte not only to operate stably for a long time and but also to improve the durability. The average service life of electrodes sold to the users exceeds two years above and the maximum service life is five year above.

TCO2 electrode is equipped with non-contact silicon pressure sensor which is imported from America. This kind of precision sensor used for industry control and aviation and aerospace is the semi-permanent appliance. In theory, it can be operated in long period. Generally, no performance may be changed after it operates for 5 - 8 years.

â–  Automatic and Intelligent Operation

SIRMA ***0 series electrolyte analyzer applies the updated embedded processor. The program control is used for test, calibration and monitor of electrode status. The instrument is equipped with intelligent monitoring sensors, which can accurately detect the sample, air bubble, waste reagent overflow alarm and standard reagent exhaustion alarm.

Since the instrument is equipped with additional sample position indicating light and standard reagent position indicating light, it is convenient and simple for users to operate the instrument and to obtain the accurate tested results.

 â–  Advanced and Unique Flow-circuit Design

SIRMA ***0 series electrolyte analyzer applies the unique flow-circuit design. It is greatly different from the two present designs:

Firstly, it applies the full electromagnetic valve to control flow-circuit instead of rotation flow-circuit distribution valve. The reliability of the electromagnetic valve manufactured in great quantities and standardization is superior to the rotation distribution valve produced by the instrument factories own, thus increasing the reliability of the instrument.

Secondly, it does not apply the flow-circuit with two independent channels including CO2 and ion analysis. TCO2 and ISE adopt the same channel and make the test respectively one after another. For this reason, flow-circuit is simple, required volume of sample decreases and reliability increases. The optimizing clearing procedure minimizes the cross pollution rate to the low level.

â–  Independent and Convenient Sampler System

At present, the fully-automatic sampler instrument has two following forms:

1. the built-in fully-automatic sampler device is integrated with the instrument as a whole.

2. An accessorial sampler device is connected to the manual sampler device in the instrument with a pipe. As for this method, since a pipe is added, the possibility of cross pollution rate greatly increases and the performance of the instrument decreases.

SIRMA ***0 series electrolyte analyzer applies the mode with built-in automatic sampler unit and external independent rotating sample turntable, it is unnecessary for the user to change the original sampler pipeline so as to realize fully-automatic sampling in purchase. SIRMA ***0 series electrolyte analyzer built-in automatic sampler unit and the external rotating sample turntable are driven directly by step motors without gear belt transmission. The structure is simplified and rational and failure rate is low.

â–  Three Measures to Ensure Accuracy

1. In order to ensure the accuracy, the reliability should be ensured firstly. All electrodes used for SIRMA ***0 series electrolyte analyzer are mounted in aluminum alloy electrode shield case. Particularly grounding sample electrode is added to make the electrode group operate stably and reliably. Even under the condition of interference, it is also used for accurate measurement.

2. The unique flow-circuit design ensures that the sampler route of sample is the shortest and simplest. In order to ensure the accuracy of all data analyzed and tested, it applies Millipore pipe diameter, air bubble test, full flushing of pipe, the method combining with automatic calibration and manual calibration and intelligent final identification for analysis method.

3. The international common calibration method is used for calibrating the tested results. The system has calibration of slope and intercept. The special quality control analysis procedures are used for the quality control report including average value (X), standard differentials (SD), coefficient of variation (CV) given after quality control measurement between both batch and batch and both day and day, either ensuring the testing level in clinical sample and indoor quality control, or adapting the QC samples of different factories so as to ensure the improvement of quality control level.

â–  Friendly Interface and Overall Data Management

SIRMA ***0 series electrolyte analyzer applies LCD liquid crystal display, English interface, YES/NO digital key combination. It is simple for this optimum operation mode and hierarchical menu control to operate. Each of operators can grasp the operation method rapidly under English leading shown in Instruction Manual.

SIRMA ***0 series electrolyte analyzer equipped with built-in printer can print all sample data, calculation data and reference value range conveniently. The internal memory of the instrument can store the measured data of ****0 above. The instrument is equipped with **2 communication interface used for communication of external computer and management software. It is convenient to check the data manually.


 

Technical features
 
Model Sirma ***0 Sirma ***0 Sirma ***0 Sirma ***0
Measuring Item K, Na, Cl K, Na, Cl K, Na, Cl, K, Na, Cl
  Ca, pH, TCO2 TCO2 Ca, pH  
Calculating item AG, nCa, Tca AG nCa, Tca  
Sampler method Automatic
Measuring time *5s *5s *0s *0s
Full time *0s *0s *0s *0
Sample size **0µl **0µl **0µl **0µl
Data storage ****0 ****0 ****0 ****0
Comunication interface **2 inrterface
Display **0 x *4 LCD Liquid crystal display, back light
Printer *8mm *8mm *8mm *8mm
Automatic sampler system **-bit s.s. for option (*0 samples,2QC,1emergency case,1washing)
Air bubble test Yes Yes Yes Yes
Alarm for waste liquid overflow Yes Yes Yes Yes
Alarm for standard liquid level Yes Yes Yes Yes
Standard liquid level indicator lamp Yes Yes Yes Yes
Sample liquid level indicator lamp Yes Yes Yes Yes
Power supply AC**0V ± *2V or AC**0V ± *1V  *0Hz ~ *0Hz  *0W
Dimentions **8 x **0 x **0 mm
Weight 7kg ( without sapler system )  1kg ( sampler system )
Measuring method ISE, TCO2 adopts pressure - measuring method
Working condition Temperature *0°C ~ *2°C    Relative humidity ≤*5%

 
Measurement parameters specifications      
         
  Measuring item Measuring scope Resolving power Precision
Sirma ***0 ( K+ ) 0.*0 - *5.*0 0.*1 CV≤ 1.0%
( Na+ ) *0.0 - **0.0 0.1 CV≤ 1.0%
( Cl- ) *0.0 - **0.0 0.1 CV≤ 1.0%
( Ca2+ ) 0.*0 - 5.*0 0.*1 CV≤ 1.0%
( H+ ) 4.*0 - 9.*0 0.*1 CV≤ 1.0%
( TCO2 ) 4.0 - *0.0 0.1 CV≤ 3.0%
         
         
  Measuring item Measuring scope Resolving power Precision
Sirma ***0 ( K+ ) 0.*0 - *5.*0 0.*1 CV≤ 1.0%
( Na+ ) *0.0 - **0.0 0.1 CV≤ 1.0%
( Cl- ) *0.0 - **0.0 0.1 CV≤ 1.0%
( Ca2+ )      
( H+ )      
( TCO2 ) 4.0 - *0.0 0.1 CV≤ 3.0%
         
         
  Measuring item Measuring scope Resolving power Precision
Sirma ***0 ( K+ ) 0.*0 - *5.*0 0.*1 CV≤ 1.0%
( Na+ ) *0.0 - **0.0 0.1 CV≤ 1.0%
( Cl- ) *0.0 - **0.0 0.1 CV≤ 1.0%
( Ca2+ ) 0.*0 - 5.*0 0.*1 CV≤ 1.0%
( H+ ) 4.*0 - 9.*0 0.*1 CV≤ 1.0%
( TCO2 )      
         
         
  Measuring item Measuring scope Resolving power Precision
Sirma ***0 ( K+ ) 0.*0 - *5.*0 0.*1 CV≤ 1.0%
( Na+ ) *0.0 - **0.0 0.1 CV≤ 1.0%
( Cl- ) *0.0 - **0.0 0.1 CV≤ 1.0%
( Ca2+ )      
( H+ )      
( TCO2 )      

بلد: China
نموذج رقم: SIRMA 2000 series
سعر فوب: 1 ~ 1 / Unit أحصل على آخر سعر
الموقع: Shanghai
سعر الحد الأدنى للطلب: 1 per Unit
الحد الأدني للطلب: 1 Unit
تفاصيل التغليف: Double carton box with shockproof
موعد التسليم: 10 days
القدرة على التوريد: 300 Unit per Year
نوع الدفع: -
مجموعة المنتج : Laboratory Diagnostic Instruments