يبدو أنك لست عضوًا في TradeKey.com بعد. اشترك الآن للتواصل مع أكثر من 7 مليون مستورد ومصدر عالميًا.
انضم الآن ، مجانًا |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
Feed Output DC24V Data Logger 0~18Channels Alarm Output Recorder Feed Output DC24V Data Logger 0~18Channels Alarm Output Recorder Feed Output DC24V Data Logger 0~18Channels Alarm Output Recorder Feed Output DC24V Data Logger 0~18Channels Alarm Output Recorder Feed Output DC24V Data Logger 0~18Channels Alarm Output Recorder Feed Output DC24V Data Logger 0~18Channels Alarm Output Recorder
Next

Feed Output DC24V Data Logger 0~18Channels Alarm Output Recorder

150 ~ 562 / Piece

|

1 Minimum Order

بلد:

China

نموذج رقم:

H8000

سعر فوب:

150 ~ 562 / Piece أحصل على آخر سعر

الموقع:

China+

سعر الحد الأدنى للطلب:

150 per Piece

الحد الأدني للطلب:

1

تفاصيل التغليف:

standard export packing

موعد التسليم:

10days

القدرة على التوريد:

5000 Piece per Month

نوع الدفع:

T/T, L/C, Western Union, Money Gram, PayPal

مجموعة المنتج :

الاتصال الآن
عضو مجاني

الشخص الذي يمكن الاتصال به Mr. Kenneth

Lugu, Changsha, Hunan

الاتصال الآن

مواصفات المنتج

  • Output Channels:0~12channels option
  • Input Channels:0~12channels option
  • Alarm Channels:0~18channels option
  • Resistance thermomet:Pt100, Cu50,Cu53, BA1,BA2
  • linear resistance:0~400Ω
  • Thermoelectric couple:B, S, K, E, T, J, R, N, F2, Wre3-25 and Wre 5-26
  • Measurement accuracy:0.2%FS±1d
  • Sampling period:1second
  • Current:0~20mA,0~10mA, 4~20mA,0~10mA evolution,4~20mA evolution

الوصف

Feed Output DC*4V Data Logger 0~*8Channels Alarm Output Recorder
 
 
Specification:
 
Input measurement
Input signal Current: 0 ~ *0 mA, 0 ~ *0 mA, 4 ~ *0 mA
Voltage: 0 ~ 5 V, 1 ~ 5 V, 0 ~ *0 V, ±5 V, 0 ~ *0 mV, 0 ~ **0 mV, ±*0 mV, ±**0 mV
Thermal resistance: Pt**0, Cu*0, Cu*3, Cu**0, BA1, BA2
Linear resistance: 0 ~ **0 Ω
Thermocouple: B, S, K, E, T, J, R, N, F2, Wre***5, Wre***6
Frequency: PI
Output
Output signal Analog output: 4 ~ *0 mA (load resistance  **0 Ω), 0 ~ *0 mA (load resistance  **0 Ω), 0 ~ *0 mA (load resistance  **0 Ω), 1 ~ 5 V (load resistance **0 KΩ), 0 ~ 5 V (load resistance **0 KΩ), 0 ~ *0 V (load resistance *0 KΩ)
Alarm output: normally open relay contact output, where the contact capacity is 1 A/**0 VAC (resistive load)
(! Note: Please do not carry load directly in case the load exceeds the contact capacity of relay.)
Feed output: DC*4 V ±1, load current  **0 mA
Communication output: RS**5/RS**2 communication interface, 1,**0 ~ *7,**0 bps baud rate (able to be set); standard MODBUS RTU communication protocol is adopted; the communication distance of RS***5 can be as long as 1 kilometer; the communication distance of RS***2 can be as long as *5 m; EtherNet communication interface is adopted, where the communication speed is *0 M.
Comprehensive parameters
Measurement accuracy 0.2% FS ± 1 d
Sampling period 1 s
Setting mode The is set in the form of panel soft touch; setting values of parameters are locked with passwords and will be saved permanently in case of outage.
Display method *-inch **0 * **0 dot-matrix widescreen TFT high brightness color graphics and LCD display; LED backlight; with clear pictures and wide visual angle.
Screen intensity can be adjusted freely.
Display contents can be composed of characters, figures, conditional curves, bar graphs, etc.; through panel , page turning, forward and backward search of historical data, time scale change of curves, etc. can be realized.
Data backup Data backup and conversion storage of USB flash disk and SD card are support, where the maximum capacity is 8 GB; FAT and FAT*2 formats are supported.
Storage capacity The capacity of the internal Flash memory is *4 M Byte.
Recording interval Nine options including 1, 2, 4, 6, *5, *0, *0, **0 and **0 s can be selected.
Storage length (continuous record without power-off) *4 days (1 s interval) ***5 days (**0 s interval)
 
Calculation formula: recorded time (day) =     
 
(! Note: For calculation of channel number, the program divides the channel number into five options, namely 4, 8, *6, *2 and *4, and the bigger figure should be regarded as the channel number for calculation in case the channel number of the instrument is between the said two options. For example: If the channel number of the instrument is *2, then *6 should be adopted in the formula.)
Environment condition Environment temperature: **0 ~ *0°C; relative humidity: *0 ~ *0% RH (without condensation of moisture); avoidance of contact of high corrosive gas.
(! Note: If the field environment is poor, special instruction should be given when ordering.)
Working power supply AC *5 ~ **4 V (power supply of the switches), *0/*0 Hz;

بلد: China
نموذج رقم: H8000
سعر فوب: 150 ~ 562 / Piece أحصل على آخر سعر
الموقع: China+
سعر الحد الأدنى للطلب: 150 per Piece
الحد الأدني للطلب: 1
تفاصيل التغليف: standard export packing
موعد التسليم: 10days
القدرة على التوريد: 5000 Piece per Month
نوع الدفع: T/T, L/C, Western Union, Money Gram, PayPal
مجموعة المنتج : Controller

Send a direct inquiry to this supplier

إلى:

Mr. Kenneth < Holykell Technology Co., Ltd. >

أريد أن أعرف: