يبدو أنك لست عضوًا في TradeKey.com بعد. اشترك الآن للتواصل مع أكثر من 7 مليون مستورد ومصدر عالميًا. انضم الآن ، مجانًا |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
Floor heating thermostat Floor heating thermostat Floor heating thermostat
Next

Floor heating thermostat

( Negotiable )

|

1 Minimum Order

بلد:

China

نموذج رقم:

HY329DH-S2

سعر فوب:

( Negotiable ) أحصل على آخر سعر

الموقع:

Beijing

سعر الحد الأدنى للطلب:

-

الحد الأدني للطلب:

1

تفاصيل التغليف:

Specification, certificate, fixing screw

موعد التسليم:

500

القدرة على التوريد:

10000 Piece per Year

نوع الدفع:

D/P

مجموعة المنتج :

-

الاتصال الآن
عضو مجاني

الشخص الذي يمكن الاتصال به 高建坤

Beijing, Beijing

الاتصال الآن

مواصفات المنتج

  • Brand Name: Electric floor heating temperature controller

الوصف

HY**9DH电热恒温器

    

     HY**9DH suitable for high-power electric heating system, heating thermostat, to meet the high-end customers. This is a state-of-the-art digital products. The ultra-thin, ultra-compact design and large LCD display, it can choose the far infrared remote control and blue background light.

Microcomputer technology thermostatic control, by measuring the temperature and the set temperature, the starting and stopping control of the heating device by the relay. In order to achieve the purpose of temperature control.      

 Unique dual temperature control function, in the detection of the temperature T1 at the same time increased the T2 temperature monitoring Control. When T1 temperature reaches the set value t1 or T2 temperature reaches the set valueT2, the automatic stop Heat and prolong the life of the heating equipment. Thus ensuring the device is able to work at a reasonable temperature, More secure and reliable.

Function:                 

        Temperature measurement and display                Temperature setting

        Delayed shutdown feature                           Power off memory

        Blue screen backlight (optional)                   Sensor fault detection function

        Dual temperature control function                  Frost protection function (optional)

Technical parameters:

        T1 temperature setting range: ***5 ℃              T2 temperature setting range:2*90 â„ƒ            

        Temperature accuracy: ± 1 ℃                      : Tact Switch

        Current load: ≤*6A (resistive)                    power supply voltage: AC**0V ± *0% ****0HZ

        Own power consumption: ≤ 1W                      working environment :***0 ℃

        Display: LCD                                       shell: PC + ABS material

        Dimensions: *6 X *6 X *3mm                        Mounting Holes: *0mm (standard)

Operating Instructions: S1:On/ off key.  S2:Mode key.  S3:Increase key.  S4:Decrease key

Turn on & Turn  off : PressS1 key to boot, press the again shutdown. 

T2 temperature check:In the standby interface, press S2 twice, you can view the T2 temperature.

T1 temperature setting:In the standby interface, you can  by S3 or S4 key to change the temperature set , such as holding the S3 or S4 more than 3 seconds, the setting value will rise or fall rapidly. After setting, the thermostat automatically confirm and return to the standby interface, the thermostat will remember this setting until you change the setting. Set temperature ≥ When measuring temperature *2 ℃, start heating. Measured temperature ≥ the set temperature, the heating was stopped. After setting automatically returns to the working state, shows the measured temperature T1. And setting the memory after power is not lost.

Timing shutdown :Press S1 to boot, default timing *5 minutes. Under the standby screen, press S2  s to display *5 and the clock icon, enter the timer to set off. S3 or S4 key can change the delay off time. After setting automatically returns to the standby interface, display clock icon, the thermostat will automatically decrement off time, when the time is zero. automatically shut down Timing shutdown setting range: *5 and *0 minutes to select two time periods. (Unit: minutes)

Regular boot settings:Turn off the thermostat, press and hold the key S2 and S4 key until the Showing *0 and the clock icon, enter the regular boot settings. You can by S3 or S4 change the snooze start time .After setting automatically  returns shutdown interface, display marks the thermostat will automatically decrement time, time is zero. automatic boot . Boot time setting range: *5 minutes and *0 minutes two kinds of time selection. (Unit: minutes)

T1 temperature return difference setting:Shut down the thermostat press and hold S2 and S4 key .until Appear *0 and the clock icon. press S2 once to display ↓ XX ℃, entering T1 temperature the return difference of setting, you can change the temperature  the return difference of S3 or S4 keys. the  flashing 8 seconds, automatic memory of the data and returns shutdown interface. T2 temperature the return difference of 2 ℃, not adjustable.

Frost protection function setting:Shut down the thermostat press and hold S2 and S4 key .until Appear *0 and the clock icon.  press S2 key twice .to display the snowflake icon .via S3 or S4 to enable or disable frost protection. (1 to enable, 0 to disable Disabled by default) settings after flashing 8 seconds, automatic memory of the data and returns shutdown interface.

T2 temperature setting:Shut down the thermostat press and hold S2 and S4 key .until Appear *0 and the clock icon. appears, press S2 key three times to display XX, entering T2 temperature setting. By S3 or S4 to change the set temperature T2  . flashing 8 seconds, automatic memory of the data and returns shutdown interface. T2 set temperature ≥ T2 when measuring temperature 2 ℃, start heating.  T2 measured temperature ≥ T2 set temperature, the heating was stopped.

Blue screen backlight functions: to facilitate operating in the dark (optional)

Frost protection function: In the off state, when the T1 temperature is below 5 ℃, it will automatically turn on and enters the heating mode until the temperature T1 ≥ 7 degrees, the thermostat automatically turns off





HY**9DH electric heating thermostat

    

     HY**9DH suitable for high-power electric heating system, heating thermostat, to meet the high-end customers. This is a state-of-the-art digital products. The ultra-thin, ultra-compact design and large LCD display, it can choose the far infrared remote control and blue background light.

Microcomputer technology thermostatic control, by measuring the temperature and the set temperature, the starting and stopping control of the heating device by the relay. In order to achieve the purpose of temperature control.      

 Unique dual temperature control function, in the detection of the temperature T1 at the same time increased the T2 temperature monitoring Control. When T1 temperature reaches the set value t1 or T2 temperature reaches the set value T2, the automatic stop Heat and prolong the life of the heating equipment. Thus ensuring the device is able to work at a reasonable temperature, More secure and reliable.

Function:                 

        Temperature measurement and display                Temperature setting

        Delayed shutdown feature                           Power off memory

        Blue screen backlight (optional)                   Sensor fault detection function

        Dual temperature control function                  Frost protection function (optional)

Technical parameters:

        T1 temperature setting range: ***5 ℃              T2 temperature setting range: 2*90 â„ƒ            

        Temperature accuracy: ± 1 ℃                      : Tact Switch

        Current load: ≤*6A (resistive)                    power supply voltage: AC**0V ± *0% ****0HZ

        Own power consumption: ≤ 1W                       working environment :***0 ℃

        Display: LCD                                       shell: PC + ABS material

        Dimensions: *6 X *6 X *3mm                         Mounting Holes: *0mm (standard)

Operating Instructions: S1:On/ off key.  S2:Mode key.  S3:Increase key.  S4:Decrease key

Turn  on & Turn  off : Press S1 key to boot, press the again shutdown. 

T2 temperature check:In the standby interface, press S2 twice, you can view the T2 temperature.

T1 temperature setting:In the standby interface, you can  by S3 or S4 key to change the temperature set , such as holding the S3 or S4 more than 3 seconds, the setting value will rise or fall rapidly. After setting, the thermostat automatically confirm and return to the standby interface, the thermostat will remember this setting until you change the setting. Set temperature ≥ When measuring temperature *2 ℃, start heating. Measured temperature ≥ the set temperature, the heating was stopped. After setting automatically returns to the working state, shows the measured temperature T1. And setting the memory after power is not lost.

Timing shutdown : Press S1 to boot, default timing *5 minutes. Under the standby screen, press S2  s to display *5 and the clock icon, enter the timer to set off. S3 or S4 key can change the delay off time. After setting automatically returns to the standby interface, display clock icon, the thermostat will automatically decrement off time, when the time is zero. automatically shut down Timing shutdown setting range: *5 and *0 minutes to select two time periods. (Unit: minutes)

Regular boot settings: Turn off the thermostat, press and hold the key S2 and S4 key until the Showing *0 and the clock icon, enter the regular boot settings. You can by S3 or S4 change the snooze start time .After setting automatically  returns shutdown interface, display marks the thermostat will automatically decrement time, time is zero. automatic boot . Boot time setting range: *5 minutes and *0 minutes two kinds of time selection. (Unit: minutes)

T1 temperature return difference setting :Shut down the thermostat press and hold S2 and S4 key .until Appear *0 and the clock icon. press S2 once to display ↓ XX ℃, entering T1 temperature the return difference of setting, you can change the temperature  the return difference of S3 or S4 keys. the  flashing 8 seconds, automatic memory of the data and returns shutdown interface. T2 temperature the return difference of 2 ℃, not adjustable.

Frost protection function setting:Shut down the thermostat press and hold S2 and S4 key .until Appear *0 and the clock icon.  press S2 key twice .to display the snowflake icon .via S3 or S4 to enable or disable frost protection. (1 to enable, 0 to disable Disabled by default) settings after flashing 8 seconds, automatic memory of the data and returns shutdown interface.

T2 temperature setting:Shut down the thermostat press and hold S2 and S4 key .until Appear *0 and the clock icon. appears, press S2 key three times to display XX, entering T2 temperature setting. By S3 or S4 to change the set temperature T2  . flashing 8 seconds, automatic memory of the data and returns shutdown interface. T2 set temperature ≥ T2 when measuring temperature 2 ℃, start heating.  T2 measured temperature ≥ T2 set temperature, the heating was stopped.

Blue screen backlight functions: to facilitate operating in the dark (optional)

Frost protection function: In the off state, when the T1 temperature is below 5 ℃, it will automatically turn on and enters the heating mode until the temperature T1 ≥ 7 degrees, the thermostat automatically turns off
 

 

بلد: China
نموذج رقم: HY329DH-S2
سعر فوب: ( Negotiable ) أحصل على آخر سعر
الموقع: Beijing
سعر الحد الأدنى للطلب: -
الحد الأدني للطلب: 1
تفاصيل التغليف: Specification, certificate, fixing screw
موعد التسليم: 500
القدرة على التوريد: 10000 Piece per Year
نوع الدفع: D/P
مجموعة المنتج : -

Send a direct inquiry to this supplier

إلى:

高建坤 < Beijing Huayang Tiandi Electronic Technology Co., Ltd. >

أريد أن أعرف: