Brand Name : GE LM 2500 PE Usage : - Production Rate : -

الوصف

GAS TURBINE

1 Unit
Package manufacturer: European Gas Turbines (EGT)
Model: GE LM2500-PE
Power output: 21.900 kW ISO conditions
Heat Consumption: 61.186 kW ISO conditions
Fuel: Natural Gas
Start up: 1994
Total running hours: 19.000 since last overhaul.
Serial nº: 481-715
Alternator: GEC Alsthom |3.000 rpm |50 Hz |6,3 kV |PF 0,8|Brushless type.
Scope of supply
Generator
Gas Turbine Package
Core Engine
Gas Generator
Air Inlet Casing
Compressor Rotor
Compressor Stator with Variable Guide Vanes
Combustion system
Power Turbine
Hot Gas Interduct
Power Turbine Rotor
Power Turbine Stator
Output Shaft Drive
Exhaust Outlet Casing
Engine Bearing Temperature Instrumentation
Engine Bearing Vibration Instrumentation.
Base plate
Start System - Hydraulic Motor and Pump - AC electric motor driven
Gears, Couplings and Guards
Main speed reducing gearbox - Epyciclic. Including all auxiliaries.
Lubricating Oil System, including main, auxiliary and emergency oil pumps, tanks, oil cooler, filters, etc.
Gas Fuel System, including conducts, fuel flow control system, rapid-acting gas shut-off valves and block and vent valves.
Accoustic Enclosure Ventilation System - 80 dBA at 1 m.
Gas Detection System
Fire Protection System
Fire Fighting sytem
Combustion Air Inlet System, including ducts, silencer and filters.
Combustion Exhaust System, including diffuser and flexible joints.
Package auxiliaries, including turbine compressor cleaning system.
Electrical Systems
Motor Control Center - off-package
Batteries and battery charger.
Control System
Unit Control System - RUSTRONIC MKII.
Generator Control System
Spare parts: List under request

STEAM TURBINE

Engines: 1 Unit
Manufacturer: ALSTOM
Power output: 4.950 kW
Steam flow: 42 t/h
Steam conditions: 60 bar(g) @ 450ºC
Steam output (min/norm/max): 6/8/10 bar(g)
Start up: 1996
Total running hours: 114.000 h
Alternator: ABB |Type: WG710 |1500 rpm | 50 Hz |6,3 kV |PF 0,8|6.200 kVA.
Scope of supply
Steam Turbine.
Generator.
Gearbox, supplied by FLENDER-GRAFFENSTADEN
Oil System
Oil tank, 5000l.
Oil vapour suction unit.
Main, auxiliary and emergency oil pumps.
Oil cooler.
Double oil filter.
Injection cooling station.
Auxiliary oil pump.
Emergency
Gas Generator

HEAT RECOVERY STEAM GENERATOR


1 Unit
Manufacturer: BALCKE-DURR
Year 1994 modified in 2000 by DBEMA.
Natural Water Circulation
Location Outdoors
Steam flow (without suplementary firing): 31 t/h
Steam flow (with max. suplementary firing): 49 t/h
Steam pressure: 60,0 bar(g)
Design steam pressure: 68,0 bar(g)
Steam temperature: 450ºC
Feed stack water temperature: 88-105ºC
Exhaust temperature: 116ºC
Burner manufacturer: ECLIPSE VAI C-8640
Burner Power: 13 MW, range 1:10

Scope of supply
Pressure parts.
HP Final superheater
HP Primary superheater
HP Evaporator
HP Economizer
Water Preheater.
Ducts and stacks .
Damper supplied by STEJASA.
Burner supplied by ECLIPSE
Deaerator and feedwater tank, 35 m3.
Feedwater pumps, 2 units, supplied by SULZER. 58,7m3/h | 778 m
Chemical dosing system.
Blowdown system. 1m3 tank.
BMS and control system.

HIGH VOLTAGE AND LOW VOLTAGE SYSTEM


Outdoor substation 50 kV.
Power transformers and auxiliary services transformer.
Gas turbine: 30,0 MVA | 50 kV-6,3 kV | Ynd 11 | Manufacturer OASA
Steam turbine: 6,5 MVA | 50 kV-6,3 kV | DYn 11 | Manufacturer OASA
For auxiliaries: 2,0 MVA | 6,3 kV-0,4 kV | DYn 11 | Manufacturer OASA
MV switchgears
Motor control center
Protections cabinets
MV cables between switchgears, generators and power transformers.

NATURAL GAS STATION

Max flow: 7.000 Nm3/h
Inlet pressure: 32 bar
Outlet pressure: 32 bar for GT | 2,5 bar for burner.

WATER TREATMENT

Demineralised water plant
Capacity: 690 m3/24 hours.
Ion-exchange, DOW-UPCORE system.
Neutralization tank, 40 m3


اتصل بنا

الشخص الذي يمكن الاتصال به:Mr. Maurici

الشركة:Energia Local S.L

عنوان:Corcega, Spain, Other, Spain,08008

رقم الهاتف:

عرض رقم الهاتف

إلى,

Mr. Maurici < Energia Local S.L >
أريد أن أعرف:

لمزيد من المنتجات من موردين آخرين

industrial cylinder, vehicle cylinders, steel tube, valve industrial cylinder
Oxygen generator package Oxygen generator package
Mwm 800kw Natural Gas Generator for Power Station Mwm 800kw Natural Gas
Commercial Gensets Commercial Gensets
Reliable water electrolysis hydrogen generator for powered electricity Reliable water electrolysis
Cryogenic Air Separation Plant Cryogenic Air Separation
compressor compressor
Releasing spear Releasing spear
GENERATOR JENBACHER, ENERGIESYSTEME AG J 320 GS-B02 GENERATOR JENBACHER
Co2 Plant Co2 Plant
CNC plasma cutting machine of Ahmadabad made in CHINA CNC plasma cutting machine
90 degree elbow 90 degree elbow
Large and medium scale Cryogenic Air Separation Unit (ASU), ASP Large and medium scale
beam pumping unit beam pumping unit
IndustrialZone IndustrialZone
Liquid air separation equipment 1200Nm³/h Liquid air separation