type beam smoke detector fire reflective type linear non-coding
sense infrared beam smoke detector . Detectors must be supporting
the use of reflectors , but requires the use of a reflector or four
different decisions based on the distance between the two installed
. Detector has the following characteristics
:
( 1 ) The
transmitter , receiver into one, easy to install, easy to use,
optical collimation is good ;
( 2 ) with
automatic calibration function , ensure the completion of
commissioning by a single person in a short , simple operation,
easy ;
( 3 ) has a self-
diagnostic function , the detector can monitor internal fault
;
( 4 ) with
automatic compensation function, for a certain degree of dust
contamination , and the position offset of the launch tube causes
the received signal is reduced aging factor can be automatically
compensated ;
( 5 ) Field set
three levels of sensitivity for different levels of dust place
;
( 6 ) has a fire
, failure of passive output contacts
;
( 7 ) to detect
optical design clever , strong anti-jamming performance
;
( 8 ) sealed
design with waterproof performance ;
( 9 ) patented
product , patent No. ZL ********7.
4.9.2 The main
technical indicators
( 1 ) Power
supply voltage : DC*5V ~ DC*8V
( 2 ) Supply
Current:
Debugging
current ≤ *0mA
Monitor
current ≤ *2mA
Alarm
current ≤ *2mA
( 3 ) the
sensitivity level
A : 1.3 ±
0.3dB
Two : 1.7 ±
0.3dB
Three : 2.3 ±
0.3dB
( 4 ) Indicator
:
Commissioning
Status: green and yellow lights lit in a particular way or
shiny
Normal monitoring
state : red LED flashes periodically
Fire Status:
Steady red light , yellow light goes
out
Fault Status :
yellow indicator light
All optical path
is blocked : first reported the fault detector and light yellow
light , *0s after the probe and reported to the fire and lit the
red light , yellow light goes out
( 5 ) Protection
area:
Detectors maximum
protection area *4 × **0 = ***0m2, maximum width of
*4m
( 6 ) Use of the
environment :
Temperature : **0
C ~ **5 C
Relative
humidity ≤ *5%,
non-condensing
( 7 )
Dimensions:
Length : **6mm
Width : *5mm Thickness : *5mm
4.9.3 structural
characteristics , installation and
wiring
The structure and
shape of the detector and reflector installation option to install
and JTY-HM-GST**2 type beam smoke detector fire the same
.
On-site
installation , you need to *4V DC power cord ( non-polar ) ,
connected to the detector terminals D1, D2; terminals K*1, K*2
fault passive output normally open contacts , terminals K*1, K*2
was no fire source output normally open contact ; reflector without
wiring. Terminals shown in Figure 1 -
*1.
Figure 1 -
*1
Wiring
requirements : Connecting K*1, K*2, K*1, K*2 twisted pair signal
lines using fire-retardant , cross-sectional
area ≥ 1.0mm2; power lines D1, D2 BV flame retardant
cable, cross-sectional
area ≥ 1.5mm2.