يبدو أنك لست عضوًا في TradeKey.com بعد. اشترك الآن للتواصل مع أكثر من 7 مليون مستورد ومصدر عالميًا. انضم الآن ، مجانًا |
BOOK A CALL
Book Call On Your Favorite Time
Code
🗘

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
High Quality Wireless Fire Alarm Smoke Detector Sound And Light Alarm High Sensitivity Detection For home Security
Next

High Quality Wireless Fire Alarm Smoke Detector Sound And Light Alarm High Sensitivity Detection For home Security

( Negotiable )

|

10 Piece Minimum Order

بلد:

China

نموذج رقم:

XY-HW-NB898

سعر فوب:

( Negotiable ) أحصل على آخر سعر

الموقع:

China

سعر الحد الأدنى للطلب:

-

الحد الأدني للطلب:

10 Piece

تفاصيل التغليف:

Carton

موعد التسليم:

30 working days according to quantity

القدرة على التوريد:

60000 Piece per Month

نوع الدفع:

PayPal, Western Union, T/T

مجموعة المنتج :

الاتصال الآن
عضو مجاني

الشخص الذي يمكن الاتصال به Luna

Guangzhou, Guangdong

الاتصال الآن

مواصفات المنتج

  • Color:White
  • Working Voltage:DC3V
  • Quiescent Current:âï¿Â&f
  • Operating Current:âï¿Â&f
  • Alarm Classification: Fire alarm, Low battery alarm, Fault alarm, Testing alarm
  • Alarm Mode:audible and visual alarm

الوصف

1. Product Descirpition

Wireless photoelectric smoke fire detection alarm (hereinafter referred to as "smoke detector") is a device that detects fire by sensing smoke. When smoke is generated and reaches a certain concentration, the device will send out an audible and visual alarm signal, and meanwhile send a wireless signal to the main gateway, prompt you to take corresponding measures on-site and remotely, effectively protect you and your family safety of life and property.


2. Tecnical Parameters

Alarm Classification: Fire alarm, Low battery alarm, Fault alarm, Testing alarm

Alarm Mode: audible and visual alarm

Alarm Volume: >*5dB(A) at 3 meters

Indicator: smoke alarm, low voltage, malfunction

Dimension: *6**6**5 mm

Weight: **6g

Mounting Position: ceilling

Power Supply: DC3V

Operating Current: ≦*0MA

Quiescent Current: ≦6uA

Battery Lifetime: *0 years (Disposable Battery CR**3)

Operating Temperature: **0℃ to **5℃

Relative Humidity: ≦*0%

Radio Frequency: **3.*2MHZ

FM Mode: ASK

Transmit Power: *0db

Radio Distance: ≦**0m (open distance)

Implementation Standards: GB *********6
 

3. Installation

(1) Add the smoke detector to the corresponding host by scanning the QR code or learning, then install the battery into the battery slot; When the power is turned on, the green light of the smoke detector will stay on for 1 second, and then initialization will begin for 5 seconds. Press the mute/self-test for about 1 second, confirm that the indicator red and green lights flash alternately once, and the buzzer beeps once, indicating that the smoke detection function is normal.

(2) Drill holes in the ceiling with a hammer drill.

(3) Install expansion screws on the ceiling.

(4) Fix the bottom plate of the housing with self-tapping screws.

(5) Align the marked points on the smoke detector and the base plate and close them, rotate them clockwise until they stop turning, indicating that they are in place.

(6) Press and hold the mute/self-test for about 3 seconds, and the buzzer will sound. The smoke detector enters the simulated alarm state. Send wireless alarm signal to main gateway.

(7) Installation Precautions:

a. Smoke detectors are only for use on indoor ceilings.

b. Avoid being exposed to the sun and keep a distance of more than *0 centimeters from lighting equipment.

c. Do not install in the bathroom, in areas prone to water or with water droplets.

d. Do not install in places where prone to generate non-fire smoke or steam.

e. When the cabinet is close to the ceiling, the smoke detector is kept at least *0 cm away from the cabinet.

f. Keep smoke detector at least 1.5 meters away from ventilation fans, air conditioners and vents.

g. When the battery is missing, the smoke detector can not be installed into the bottom plate.

h. Smoke detector operate at temperatures from **0°C to **5°C. Do not install in environments outside this range.


4. Fire Alarm Function

(1) Smoke Detected

The smoke detector will send outaudible and visual alarm prompts immediately after it detects smoke, and meanwhile sends wireless alarm messages to the main gateway.

Note: There is no limit on the number of alarm messages sent within *2 hours after the smoke detector is powered on. It will enter the cost-saving mode after *2 hours of power on.

( If the alarm message exceeds ten times in an hour, it will be limited to ten minutes before sending a wireless signal. When the alarm does not occur for *4 consecutive hours, it can return to normal. )

(2) If a fire occurs, take appropriate measures in a timely manner, such as calling **9, using fire extinguishing equipment, etc.

(3) If there is no fire, you can press the mute/self-test to mute the alarm (the mute time is about *2 hours, during which there is no sound prompt), you can long press the mute/self-test for more than 3 seconds to cancel the mute function.

(4) Note: The following situations may trigger a fire alarm

a. Sprayed insecticides, make-up, etc. emit a mist that comes into direct contact with smoke detector.

b. Smoke from burning materials such as cigarettes and incense comes into contact with the smoke detector.

c. Smoke-type, gradually heated evaporative insecticide sprays mist that comes into contact with smoke detector.

d. Cooking fumes or steam, etc. coming into contact with the smoke detector.

e. Alarm condensation
 

5. Fault Alarm Function

(1) Automatically test whether the function is normal

If the smoke cannot be detected normally (in case of malfunction), please contact the dealer for inspection or repair as soon as possible. The smoke detector will not detect smoke and will not sound a fire alarm in the event of a fault. Note: There is no wireless signal prompt for fault alarm.

(2) Fault silence

a. When the smoke sensor detects a malfunction, the indicator light will flash yellow three times continuously every *0 seconds or so, and the buzzer will beep three times continuously at the same time, please contact the maintenance personnel for inspection and repair as soon as possible.

b. When a fault alarm occurs, pressing the Mute/Self-Test will silence the fault alarm for approximately *5 days.

c. When the fault alarm is silenced, long press the Silence/Self-test for more than 3 seconds to release the silencing function.
 

6. Low battery Alarm Function

(1) When the battery is low, the indicator light will flash in yellow every *0 seconds or so, and the buzzer will beep once, please replace the battery as soon as possible; after the low battery alarm, a wireless signal reminder will be sent every 2 hours.

(2) When a low battery alarm occurs, pressing the silence/self-test will silence the low battery alarm for approximately *5 days.

(3) When the low battery alarm is silenced, long press the mute/self-test for more than 3 seconds to release the silencing function.
 

7. Tamper Alarm Function

Press and hold the tamper switch for about *0 seconds and then release it. The smoke detector will send out an tamper alarm message (the wireless signal is the same as the smoke alarm), and without buzzer sound prompt.

Note: Only a maximum of *4 tamper alarm messages are allowed to be sent per day.


8. Heartbeat Function

(1) The smoke detector will send heartbeat data to the main gateway every 2 hours. The main gateway uses this signal to prompt offline or online.

(2) When the smoke detector is low voltage, the heartbeat data sent becomes low voltage data.
 

9. Alarm Test Function

(1) Press and hold the Mute/Self Test for about 3 seconds and the buzzer sounds. (Wireless signal is the same as smoke alarm).

Note: Only a maximum of *4 alarm test messages are allowed to be sent per day

(2) When the Mute/Self-Test is released, the buzzer stops beeping and the smoke detector exits the simulated alarm state.

Note: When the battery power is low or the smoke detector fails or the smoke alarm occurs, the alarm test function is disabled, press and hold for 3 seconds to release the silencer function.


*0. Self-test Function

(1) Press and hold (about one second) the mute/self-test to perform self-test.
 

Serial Number Indicate Status Buzzer Status
Normal working status Red and green flash alternately once Beep once
Low battery alarm silence state Yellow flashes once Beep once
Fault alarm silence state Yellow flashes three times Beep three times
Fire alarm silence status Red flashes three times Beep three times

(2) When the smoke detector is normal, the green light will flash once every *0 seconds. If not, please check whether the battery is exhausted or the device is malfunctioning.

Note: Perform self-test on the smoke detector(recommended monthly). If any fault is found, please repair it in time.


*1. Replacement Battery

(1) Remove the smoke detector

(2) Remove the battery, press and hold the Mute/Self-Test for about 3 seconds and then release it (to release the residual power of the smoke detector before re-powering).

(3) Insert the new battery, if you see the smoke detector green light stays on for about 1 second, it means the power is successfully powered. Otherwise, repeat step 2.

بلد: China
نموذج رقم: XY-HW-NB898
سعر فوب: ( Negotiable ) أحصل على آخر سعر
الموقع: China
سعر الحد الأدنى للطلب: -
الحد الأدني للطلب: 10 Piece
تفاصيل التغليف: Carton
موعد التسليم: 30 working days according to quantity
القدرة على التوريد: 60000 Piece per Month
نوع الدفع: PayPal, Western Union, T/T
مجموعة المنتج : Alarm System

Send a direct inquiry to this supplier

إلى:

Luna < Shenzhen Patrol Hawk Technology Co., Ltd. >

أريد أن أعرف: