1. Summarization
This instrument is used to judge the degree of aging by testing
the dielectric loss of insulation oil. The resistivity of
insulation oil can also be tested.
Dielectric loss factor is very sensitive to aging product. When
the aging degree is little, it is difficult to notice through
common chemical method. Dielectric loss factor can be used to
identify it apparently.
The instrument is produced according to national standard
GB/T***4.
The instrument adopts the advanced technology, such as wavelet
analysis of digital technology and automatic intelligent testing,
to test dielectric loss. The instrument has built-in sample cup,
temperature control, digital bridge, sophiscated high-resistance
meter, AC-DC power. It has features such as easy operation,
stability and good repeatability. Testing results can be
displayed, printed and stored automatically.
2. Features & Technical Specification
(1) Features
1. Temperature is raised quickly, steadily without overshoot by artificial intellegence netural network controlling technoloty.
2. Precision processing elcotrode of new technology cup is applied.
3. The advanced technology, such as wavelet analysis of digital
Technology and high precision resistance meter, guarantees the testing results of high precision and good repeatability.
4. The operation is easy and of high automation. It can automatically test, calculate, store and type the results. The real-time date, time and day are displayed. **0 groups of data can be stored.
5. Big screen monitor is applied. Convenient new interface, which is close to WINDOWS, is adopted to accord with computer operation habit.
6. Overcurrent, over voltage, electric shock protection, safe operation by humanized design.
(2)Technical specification
1. Precision: Cx ± ( Reading x 1% + 1pF) (automatically
calculated)
Tgδ ± ( Reading x 1% + 0.***1)
ρ ± ( Reading x *0%)
Temperature ± 0.5 degree
2. Tgδ Scope: No limit, Resolution 0.**1%
3. Capacitance Range: 1pF_**0pF, Resolution 0.*1pF
4. ρ scope: 1.*0 x **6_1.*0 x ***4 Ωm (Scientific notation, 3 effective digital)
5. Temperature scope: Room temperature_**0 degree
6. AC testing voltage: ***0V_***0V, Frequency *0/*0Hz (Crystal produced)
7. DC testing voltage: **0V, maximum error: 1%
8. Charging time: 0_*9s
9. Discharging time: 0_*9s
*0. Sample cup parameter:
Electrode spacing: 2mm
Electrode type: *-elctrode
Empty-cup dielectric loss: Almost 0
Sample cup capacity: *0ml
Empty-cup capacitance: *0 ± 5pF
*1. Monitor screen: **0 x **0 (Blue) ( Display like WINDOWS)
*2. Printer: **3 thermal micro-printer
*3. Dimension: **0***0***0cm3, about 9kg
*4. Input supply: **0V AC ± *0% *0Hz
*5. Power: **0W
*6. Working Environment:
Temperature: 0 degerr _ *0 degree
Humidity: ≤ *5%1. Summarization
بلد: | China |
نموذج رقم: | HDJ3100 |
سعر فوب: | ( Negotiable ) أحصل على آخر سعر |
الموقع: | CHINA |
سعر الحد الأدنى للطلب: | - |
الحد الأدني للطلب: | 1 |
تفاصيل التغليف: | - |
موعد التسليم: | 4WEEK |
القدرة على التوريد: | 6 |
نوع الدفع: | T/T |
مجموعة المنتج : | - |