The purpose of the meter and its field of use is
the execution of electromagnetic tests of transformers of all
circuits and connection groups.
List of basic functions during single-phase and
three-phase excitation of the tested
transformer:
· current
and idling loss measurement at low
voltage;
· short-circuit
resistance measurement;
· transformation
ratio measurement;
· determination
of connection groups of three-phase transformer windings and
terminal polarity of single-phase
transformers;
· measurement
of DC copper resistance.
During the measurement, the asymmetry, the
unsinusoidality and the excitation voltage frequency are
controlled.
The function of the meter is maintenance, repair, setting-up, and
testing of power transformers, both in laboratory and filed
conditions by the services of
ORGRES.
Technical
specification
Measured AC range (three
channels)1, A, 0.***5.
Measured AC voltage range (two three-channel
meters)2, A, ****0.
Measured active power range (three
channels)1,2,
W, *****0.
Measured DC copper resistance range, Ohm, 0.*********9.
Measured frequency range, Hz, ****5.
Current measurement limits, A, *5.
Voltage measurement limits, V, ******0.
Resistance measurement limits, Ohm, 0.*********9.
Basic reduced voltage measurement error at each of limits, max., %,
0.2.
Basic reduced power measurement error, max., %, 0.5.
Basic reduced current measurement error, max., %, 0.5.
Absolute frequency measurement error, max., Hz, 0.*5.
Basic reduced DC copper resistance measurement error, %, 0.5.
Input resistance of voltage measurement channels, min., kOhm,
**0.
Load voltage drop of current strength measurement channels, max.,
mV, *5.
Average service lifetime of the device, min., years, 8.
Mean time to failure, min., h, ****0.
The permissible auxiliary measurement error caused by the ambient
air temperature change relative from normal to limiting values in
the operating temperature range does not exceed the limit of
permissible basic error.
Notes:
1
without using an external current measuring
transformer;
2
without using an external voltage measuring
transformer.