يبدو أنك لست عضوًا في TradeKey.com بعد. اشترك الآن للتواصل مع أكثر من 7 مليون مستورد ومصدر عالميًا. انضم الآن ، مجانًا |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
MIX8411 CO Gas Sensor 2000ppm Carbon Monoxide Sensor
Next

MIX8411 CO Gas Sensor 2000ppm Carbon Monoxide Sensor

|

- Minimum Order

بلد:

China

نموذج رقم:

-

سعر فوب:

أحصل على آخر سعر

الموقع:

-

سعر الحد الأدنى للطلب:

-

الحد الأدني للطلب:

-

تفاصيل التغليف:

-

موعد التسليم:

-

القدرة على التوريد:

-

نوع الدفع:

-

مجموعة المنتج :

-

الاتصال الآن
عضو مجاني

الشخص الذي يمكن الاتصال به Kim

Shenzhen, Guangdong

الاتصال الآن

مواصفات المنتج

الوصف

Principle Introduction:

 

MIX***1 is an electrochemical Carbon Monoxide ( CO) sensor developed by Mixsen. It uses the principle of electrochemistry. There is a reference electrode inside the sensor, which greatly improves the stability of the sensors. When the sensor senses the carbon monoxide, the working electrode and the counter electrode react with the redox reaction, through measure the current to get the concentration of CO gas.

 

Feature:

 

Low power consumption;
High precision;
High sensitivity;
Wide linear range;

Long service life
Temperature compensation
Anti-vapor interference
Good anti-interference ability;

Environmental protection design

 

Application:

 

* Industrial co gas monitors, leakage detection

* Fixed or portable CO gas detector

 

Technical Parameters :

 

Item Specification
Target Gas Carbon Monoxide(CO)
Measurement Range 0~***0 ppm
Maximum Overload ***0 ppm
Output 0.1 ± 0.*2 μA/ppm
Repeatability ±2%
Response Time(T*0) < *0 Seconds
Resolution 0.5 ppm
Long Term Output drift <*0% per year
Life Expectancy(in air) 3 Years
Operating Temperature Range **0 ~ *0ËšC
Operation Press 0.1MPa±*0%
Operating Humidity Range *5% ~ *5% RH, no-condensing
Note: All measurements were taken at *0ËšC, *0%RH at ***3hPa


Operating Note:

* Forbidden tin soldering before usage.
* Aging for more than *8 hours before using.
* Sensors pins cant be broke off or bent.
* Dont disassemble the sensor to avoid the damage caused by electrolyte leakage.
* Avoid contacting organic solvent (including silicone rubber and other adhesive), coatings, medicine, oil and high concentration gases.
* All the electrochemical sensors shall not be encapsulated completely by resin materials, and shall not immerse in pure oxygen environment,   otherwise, it will damage the function of sensor
* All electrochemical sensors shall not be applied in corrosive gas environment, or the sensor will be damaged
* Zero calibration should be finished in clean air.
* During test and usage, sensors should avoid the gas inflow vertically
* The side for inflow cant be choked and polluted.
* The laminating film above the sensor surface cant be uncovered and damage.
* Excessive impact or vibration should be avoided
* It takes some time for the sensor to return to normal state after it is applied in high concentration gas.
* Working electrode and reference electrode of the sensor shall be in short circuit when stored
* Prohibit to use the hot cement or sealant of which the curing temperature is higher than *0℃ to make the capsulation for the sensor.
* Prohibit storage and usage for long time in alkaline gases with high concentration.
* Do not use the sensor when the shell is damaged.

بلد: China
نموذج رقم: -
سعر فوب: أحصل على آخر سعر
الموقع: -
سعر الحد الأدنى للطلب: -
الحد الأدني للطلب: -
تفاصيل التغليف: -
موعد التسليم: -
القدرة على التوريد: -
نوع الدفع: -
مجموعة المنتج : -

منتجات ذات العلاق Shenzhen Mixsen Electronics Co., Ltd.

Send a direct inquiry to this supplier

إلى:

Kim < Shenzhen Mixsen Electronics Co., Ltd. >

أريد أن أعرف: