Principle Introduction:
MIX***1 is an electrochemical Carbon Monoxide ( CO) sensor developed by Mixsen. It uses the principle of electrochemistry. There is a reference electrode inside the sensor, which greatly improves the stability of the sensors. When the sensor senses the carbon monoxide, the working electrode and the counter electrode react with the redox reaction, through measure the current to get the concentration of CO gas.
Feature:
Low power consumption;
High precision;
High sensitivity;
Wide linear range;
Long service life
Temperature compensation
Anti-vapor interference
Good anti-interference ability;
Environmental protection design
Application:
* Industrial co gas monitors, leakage detection
* Fixed or portable CO gas detector
Technical Parameters :
Item | Specification |
Target Gas | Carbon Monoxide(CO) |
Measurement Range | 0~***0 ppm |
Maximum Overload | ***0 ppm |
Output | 0.1 ± 0.*2 μA/ppm |
Repeatability | ±2% |
Response Time(T*0) | < *0 Seconds |
Resolution | 0.5 ppm |
Long Term Output drift | <*0% per year |
Life Expectancy(in air) | 3 Years |
Operating Temperature Range | **0 ~ *0ËšC |
Operation Press | 0.1MPa±*0% |
Operating Humidity Range | *5% ~ *5% RH, no-condensing |
Note: All measurements were taken at *0ËšC, *0%RH at ***3hPa |
Operating Note:
* Forbidden tin soldering before usage.
* Aging for more than *8 hours before using.
* Sensors pins cant be broke off or bent.
* Dont disassemble the sensor to avoid the damage caused by
electrolyte leakage.
* Avoid contacting organic solvent (including silicone rubber and
other adhesive), coatings, medicine, oil and high concentration
gases.
* All the electrochemical sensors shall not be encapsulated
completely by resin materials, and shall not immerse in pure
oxygen environment, otherwise, it will damage the
function of sensor
* All electrochemical sensors shall not be applied in corrosive
gas environment, or the sensor will be damaged
* Zero calibration should be finished in clean air.
* During test and usage, sensors should avoid the gas inflow
vertically
* The side for inflow cant be choked and polluted.
* The laminating film above the sensor surface cant be uncovered
and damage.
* Excessive impact or vibration should be avoided
* It takes some time for the sensor to return to normal state
after it is applied in high concentration gas.
* Working electrode and reference electrode of the sensor shall
be in short circuit when stored
* Prohibit to use the hot cement or sealant of which the curing
temperature is higher than *0℃ to make the capsulation for the
sensor.
* Prohibit storage and usage for long time in alkaline gases with
high concentration.
* Do not use the sensor when the shell is damaged.