يبدو أنك لست عضوًا في TradeKey.com بعد. اشترك الآن للتواصل مع أكثر من 7 مليون مستورد ومصدر عالميًا.
انضم الآن ، مجانًا |
Book call on your favorite time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Amazon Services

Perfict Lab Limited

FL.2 No.4 Building, Software Park, Central District High-tech Industrial Park,Shenzhen,Guangdong,China

عرض رقم الهاتف

عضو مجاني

Prcbe Mini Series Probe Station failure analysis wafer prober

China

Mini Series

5000 ~ 6000 / Set ( Negotiable ) أحصل على آخر سعر

China

5000 per Set

1 Set

-

-

10 Set per Month

T/T

Probe Station

الاتصال الآن

مواصفات المنتج

Brand Name : PRCBE Power : - Usage : -

الوصف

Product Features:
1.Small footprint (44cm x 28cm x49cm);
2.Very cost-effective;
3.Simple and easy operation;
4.Applied in tests for pads down to 50 micron or wafers up to 4";
5.For I-V / C-V test and RF test;
6.Short delivery time:Within two weeks for standard Mini probe station;
7.This probe station is sold with a MOTIC long working distance stero microscope.

Description:
1.Mini series probe station is designed with small footprint with very simple functions.They provide enough space and high price raio test with simple and efficient framwork and function design.
2.User will no longer have to wait for more than 8 weeks for a probe station.Standard Mini series cab be delivered within two weeks.
3.Mini series is compatible with various accessories which users to apply in various tests, such as I-V test with leakage performance less than 100fA, capacitive test with resolution of 0.1pF, and DC-67GHz microwave test, etc.
4.Mini series only provides basic probe station functions, which ease the use of a probe station.These functions include chuck X-Y, the movement and vacuum fixation for DUTs and wafers up to 4".
5.Four vibration isolation pads are installed under the probe station base to reduce the vibration from outside the probe station.
6.The compact and completely built-in vacuum pipes contribute a lot to the convenient operation of the chuck movement. User can efficiently perform tests without any disturbance from the vacuum pipe (whihc usually install at the rear side of the chuck).

Specifications:
Chunk
Size 4" (101.6mm)
Material Stainless steel
Planarity ≤±2.5 micron
Vacuum Area 0", 2", 4", Circular adsorpation
Vacuum Control Manual control, separate vacuum area
Chunk Electrical properties Chuck can be grounded or connected to the test instrument

With a cable

Chunk Stage
 
X-Y travel range 2"*2" (5.8mm*50.8mm)
Resolution 10 Micron
Theta rotation 360 degree

Platen System
Material Nickel plated stainless steel
Space Accommodates up to 8 SE40 or 4 SE80
Height from platen to chunk (min.) 1.496" (38mm)
Compatibility Compatible with magnetic or vacuum probe base

Microscope Stage
Holder Stainless boom stand
Z travel range 2" (50mm)

Microscope
Type MOTIC long working distance stereo microscope
Magnification 15X-100X
Video mount C-Mount
Light Source LED ring light

Others
Physical dimensions 440mm*280mm*490mm (W*D*H)
Net Weight 21kg

Environmental requirement
Power 220V±10% (Light source)
Vacuum -8bar
Compressed air N/A
Remark:1.A vacuum pump will be needed for chuck vacuum fixation.

Warranty
If defective products are caused by inferior raw materials or the lack of manufacturing process, we will provide replacement service and bear the return freight.
For Returns & Refunds, it should be applied within 14 days after you get the items.After that period, we only accept replacement instead of refund.But in case we could not provide right item for your requirements after all the efforts, we can accept return & refund, for all the return & refunds, the buyer shall bear the round-trip shipping cost.

Payment
Perfictlab accepts PayPal only.
Winning bidder must make payment arrangements within 3 days!
If payment has not been received within 7 days of auction closure the item will be delivered to Resolution center.

Shipping
Perfictlab attempt to ship your item within 48 hours after payment has been received.
We are happy to ship to all countries worldwide.Our Current International Express such as USPS, China Post Registed Mail, DHL, UPS, and FedEx are optional upon your request.
If you want us to change the shipping method, please contact us first.We will try to find the best shipping way according to different location.
For the Shipping Price, it includes all packing and handling fees.But customs fees, Duties, Tariffs, Taxes, etc.Are not included.
At last, in order for you to get the items smoothly, please confirm your destination address and contact number after you make the payment.

*****International Buyers - Please Note:Import duties, taxes, and charges are not included in the item price or shipping cost.These charges are the buyer's responsibility.Please check with your country's customs office to determine what these additional costs will be prior to bidding or buying.Contact a freight forwarder who can get you actual prices.*****

Feedback
Your feedback is very important to us.If you have any concerns or questions regarding our products, please contact us as soon as possible with eBay message or email:, we will reslove your problem right away.Thank you!

About us
Perfict lab was founded in Shenzhen Hi-tech Industrial Park in 2005.
As an independent commercial lab, Perfict lab applies itself to being the public laboratorial platform of IC industry, offering professional IC analysis services of high-quality, including IC chemical processing, microcircuit modification, IC micrograph & IC Failure analysis.
Perfict Lab has an increasingly growing customer group of over 220 customers.And this faithful and steady customer group includes IC design houses, fablesses, fabs, individual IC designers, electronic device manufactories and sellers, and many other kinds of companies.

As a very flexible lab, Perfict Lab keeps offering its customers all kinds of special and specified services.In fact, many of these cases are not tough cases, just not so frequently asked.So, if any needs about IC analysis, feel free to contact us.

Perfict Lab set up special study projects and offer comprehensive solutions for special cases.

Every day, maybe just at the same moment you're viewing this page, tens of IC specimens get into Pperfict Lab and begin their journey from defectiveness to perfectness.Perfict Lab is just where the journey begins and part of this journey, but the most significant part as well.

We appreciate your confidence.

Contact us
Perfict LAB LTD
Room 210, No.4 Building, Software Park,
Central District High-tech Industrial park,
Shenzhen, 518057
P.R.China

Ms.Tao
Phone:+86-755-86169688
Mobile:+86 13339953200

اتصل بنا

الشخص الذي يمكن الاتصال به:Ms. Yan

الشركة:Perfict Lab Limited

عنوان:FL.2 No.4 Building, Software Park, Central District High-tech Industrial Park, Shenzhen, Guangdong, China,

رقم الهاتف:

عرض رقم الهاتف

التليفون المحمول:

عرض رقم الجوال

إلى,

Ms. Yan < Perfict Lab Limited >
أريد أن أعرف:

لمزيد من المنتجات من موردين آخرين

2M  Pipe Water Leak Detector PQWT-CL200 2M Pipe Water Leak
GF302D Portable Three Phase Electricity Meter Test Equipment Kwh meter calibrator GF302D Portable Three Phase
Oil Tester Oil Tester
Testing instrument for syringes, needles, and other medical devices Testing instrument for
PI2STAR Intelligent Wireless Sensor for Pump Condition Monitoring PI2STAR Intelligent
HV wireless current sensor ammeter recorder GF2018 HV wireless current sensor
Three Phase Power Analyzer GFUVE FU2200A 96*96mm Multifunction Power M Three Phase Power Analyzer
AC Test Transformer System (HCTT / HTTS / HGTS) AC Test Transformer System
wire tracker and cable tester for RJ45 RJ11 BNC wire tracker and cable
UM Series Ultrasonic Thickness Gauge UM Series Ultrasonic
Vibration Analyzer DC-23 Vibration Analyzer DC-23
ZL10-1 weighing device ZL10-1 weighing device
Thermal shock chamber Thermal shock chamber
Stanford Research System SR560 Low Noise Preamp IN STOCK 2/10/2014 Stanford Research System
GTS8202 split type bi-function coating thickness gauge by GuoOu GTS8202 split type
PERX Peroxide Test 100 (Fast and easy determination of Peroxide residuals) PERX Peroxide Test 100