808 S. Hobart Blvd. #406,Los Angeles,California,USA
Â
Gas valves should be installed by a plumber who is a licensed gas fitter.
Product DetailsThe 710 low capacity gas heating valves are designed for recreational vehicles and other applications with limited space. All models include a manual valve (gas cock), automatic pilot safety valve, pilot outlet, pilot gas filter and pilot adjusting key. THE CONTROL CAN BE MOUNTED IN ANY POSITION EXCEPT UPSIDE DOWN AND ALL MODELS HAVE 3-POSITION OUTLETS. Consult ordering chart for individual control specifications.
NOTE:Â Regulated 710 series gas valves can be converted from natural to L.P. gas by using the replacement pressure regulators.
Use 1751-003 to convert gas valves to Natural Gas. Use 1751-013 to convert gas valves to L.P. Gas.
Valve type |
see ordering chart |
Temperature range (hydraulic models) |
58° to 90°F |
Pilot outlet |
1/4" tubing |
Gas cock dial marking |
off-pilot-on |
Maximum ambient temperature |
175°F |
Maximum capacity natural gas |
70,000 |
Maximum capacity L.P. gas |
112,000 |
Maximum inlet pressure |
14" W.C. (1/2 PSI) |
Attribute |
Right Valve® |
Robertshaw® |
 |  |
710-501 |
Factory model |
GM970-A-17-05 |
7000 MVLC |
Inlet Size |
1/2" |
1/2" |
Pressure regulator setting |
None |
None |
Comments |
 |  |
Application |
 |
Space heaters replaces B-67 |
Capillary Length |
N/A |
N/A |
Description |
Millivolt Note: Use two lead thermopiles only. |
Millivolt Note: Use two lead thermopiles only. |
Outlet Size |
1/2" |
1/2" |
Reducer Bushing (NPT) |
(2) 1/2" x 3/8" |
(2) 1/2" x 3/8" |
الشخص الذي يمكن الاتصال به:Mr. Jonathan
الشركة:Right Valve and Energy Control LLC
عنوان:808 S. Hobart Blvd. #406, Los Angeles, California, USA,90005
رقم الهاتف:
عرض رقم الهاتف
التليفون المحمول:
عرض رقم الجوال