Three phase
isolation transformer is mainly used in low voltage distribution
system, isolating load from power supply. Distribution system is
divided into TN, TT and IT. The first T indicates that the neutral
point of power transformer is directly grounded. I indicates the
neutral point of power transformer is non-grounded(or grounded
through high impedance). The second T indicates that the case of
electrical equipment is directly grounded, but have no connection
with the power grid of ground system. And N indicates that the case
of electrical equipment is connected with the grounded neutral wire
of system.
TN system: the
neutral point of power transformer is grounded and the case of
equipment is partially connected with neutral
wire.
TT system: the
neutral point of power transformer is grounded and the case of
equipment adopts protection grounding.
IT system: the
neutral point of power transformer is non-grounded but the case of
equipment adopts protection grounding.
In the IT system,
isolation transformer can prevent electric shock, protect the
connected equipment from insulation damage and make the neutral
point isolated.
Technical
parameters:
1, Power
range ≤***0KVA
2, Dielectric
strength: winding-winding,
winding-earth ***0VAC / *0Hz
/ *0s no arcing or breakdown
3, Insulation
resistance: cross-core
screw rob - earth **0VDC,
insulation resistance value ≥**0MΩ
4, Noise level < *5 db
(The testing point's horizontal distance from transformer
should be 1 metre.)
5, Protection grade:
IP*0
6, Insulation class:
H
7, Product
standards: IEC**6**1 Dry-type
power transformer
GB***4.******7 Dry-type
power transformer
IEEE.C*7.*2.******5
General requirements for dry-type power
distribution and power
transformer
Application environment
and conditions:
1, The altitude is not more than
***0 meters and if more than ***0 meters, derating is
required.
2,
Running temperature: *5℃-*0℃,
relative humidity is less than
*0%.
3,
Without harmful gas, inflammable, explosive and conductive dust
around.
بلد: | China |
نموذج رقم: | - |
سعر فوب: | 10 ~ 15000 / Piece ( Negotiable ) أحصل على آخر سعر |
الموقع: | - |
سعر الحد الأدنى للطلب: | 10 per Piece |
الحد الأدني للطلب: | 1 Piece |
تفاصيل التغليف: | packing in wooden cases |
موعد التسليم: | 2-3 weeks |
القدرة على التوريد: | 5000 Piece per Month |
نوع الدفع: | T/T |
مجموعة المنتج : | Three phase isolation transformer |