سعر فوب
أحصل على آخر سعر|
1 Piece Minimum Order
بلد:
China
نموذج رقم:
10kv~220kv, SZ11, S11
سعر فوب:
الموقع:
-
سعر الحد الأدنى للطلب:
-
الحد الأدني للطلب:
1 Piece
تفاصيل التغليف:
-
موعد التسليم:
-
القدرة على التوريد:
100 Piece
نوع الدفع:
-
مجموعة المنتج :
-
الشخص الذي يمكن الاتصال به Cathy
15th Floor,Block D,Building 18,No.283 Xisanhuan Road, High-Tech District, Zhengzhou City, Henan Prov, Zhengzhou, Henan
Model NO.: *0kv~**0kv, SZ*1, S*1
Phase: Three
Cooling Method: Oil-immersed Type Transformer
Certification: ISO********0, ISO***1, CCC, Kema CE
Frequency Characteristics: High Frequency
Brand: Pearl Electric
Capacity: up to **0mva
Reference Standard: IEC ****6
Specification: IEC
HS Code: *****3
Application: Power, Electronic, Instrument, Lighting, Rectifier,
Audio
Coil: Core-type Transformer
Winding Type: Two-winding Transformer
Usage: Power Transformer
Shape of Coil: U
Manufacturer: Pearl Electric Co., Ltd.
Voltage Class: up to **0kv
Trademark: Pearl
Origin: China
Payment Terms: L/C, T/T, D/P
Production Capacity: **0 pieces
Min. Order: 1 Piece
FOB Price: US $1,**0
Product Description
1, Oil-immersed Power Transformer covers the following range:
1.1, *2kV oil-immerse power transformer
1.2, *3kV oil-immerse power transformer
1.3, *6kV oil-immerse power transformer
1.4, *8kV oil-immerse power transformer
1.5, **0kV oil-immerse power transformer
1.6, **5kV oil-immerse power transformer
1.7, **0kV oil-immerse power transformer
1.8, On-load tap-changing power tansformer
1.9, Off-load tap-changing power transformer
1.*0 Three-phase two-winding oi-immersed power transformer
1.*1 Three-phase three-winding oil-immersed power transfrmer
2, Features and Characteristics
The low-loss oil-immersed power transformer manufactured by Pearl
Electric with "Pearl" brand is the product designed and developed
on the basis of absorbing the most advanced technology at home and
abroad. It features high reliability, low partial discharge, low
noise, low loss and high anti-short circuit capability. Its
excellent and reliable performance have won customers' as well as
experts' reorganizations and appreciations.
Three-Phase Two-Winding Onan/Onaf Oltc/Octc Oil-Immersed Power
Transformer
Generals
The oil-immersed power transformer manufactured by Pearl Electric
with "Pearl" brand is the main product designed and developed on
the basis of absorbing the most advanced technology at home and
abroad. It features high reliability, low partial discharge, low
noise, low loss and high anti-short circuit capability. Its
excellent and reliable performance have won customers' as well as
experts' reorganizations and appreciations.
Specifications:
Rated H.V.: *2, *3, *6, *8, **1, **5, **0kV or
customize
Vector Group YNd*1, Dyn*1 or customized
Rated L.V.: 6.3 (6.6, *0.5, *1)kV or custoized
Capacity: up to **0MVA
No-load Loss: Customized for each type
Load Loss Customized for each type
No-load Current: Customized for each type
Impedance Voltage: *0.5% or Customized for each
type
Tap-changing On-load Tap-changing or off-load
tap-changing
Cooling Method: ONAN/ONAF
Reference Standards IEC****6
Notes: The above specifications may be customized according to
customer's requirement.
Features & Advantages
1. Low partial discharge: the apparent discharge quantity is
usually less than **0pC;
2. Low noise: Product of *3MVA or below *3MVA has a noise level
less than *0dB;
3. Low loss: no-load loss is reduced by *0 percent compared with
that specified in national standards;
4. High anti-short capability: the SFZ*******0/**0 transformer has
passed the short-circuit test carried out by China National
Transformer Quality Supervision Testing Center.
Electromagnetism calculation:
The insulation strength is comprehensively calculated with
reference to the formula of "impulse voltage gradient+ actuation
duration". Parsing imaging method is used for precisely calculating
winding magnetic field and ampere-turn balance between windings,
thus to minimize the mechanical strength.
Electric field wave process and field intensity are calculated,
thus to ensure both the principal and longitudinal insulation
having sufficient strength under impulse voltage. Advanced
auxiliary computer programs are used to simulate and calculate the
temperature rise on core and windings, with precision reaching each
core step and each winding disk.
Winding:
The interleaved and continuous winding structure is adopted for HV
windings, thus to improve the electric distribution and effectively
improve the anti-lightning impulse capability. Inner and outer
support strip structure is adopted. The support strips and pads are
all rounded to improve insulation reliability. Oil-directing
structure is adopted in the winding, thus to reduce the hotspot
temperature and prolong insulation life.
Both the H.V and M.V. windings are usually provided with separate
voltage regulating windings, so the ampere-turn of all the windings
are completely balanced. These can effectively eliminate the axial
electrodynamics force during external short circuit and improve the
dynamic stability under external short circuit.
Tank:
Bell-type tank is adopted for the transformer (for transformer of
below**0MVA, barrel-type tank is used). The tank wall is made into
a corrugated shape with special machining equipment. This will
reduce the welding work and the mechanical strength will be much
improved. The tank rims are sealed with oil-resistant rubber pad
and there is a position-limit device on bottom part of the
tank.
Core:
High-quality cold-rolled grain-oriented silicon steel sheets are
used for core manufacturing. **-degree mitring and
steps-overlapping structure is adopted. No punching holes in the
core. The silicon steel sheet is cut with the most advanced cutting
machine, with the cut edging burrs less than 0.*2mm. This greatly
reduces transformer's no-load loss.
Cooling Devices and Other Accessories:
The main cooling methods for transformers are ONAN (natural air
cooling) and ONAF (air forced cooling). Transformers are designed
to operate at full load when fans are in operation, and at *0% of
the full load when fans are shut down. Panel-type radiators are
used. A more compact size can be obtained for transformers equipped
with such radiators .The fans generally blow horizontally, with
lower speed and lower noise. The on/off operations of the fans are
controlled according to changes in oil temperature and load.
Conservator with rubber bladder is used for the transformer, within
which are the oil-resistant and sealed bladder for isolating the
oil from the atmosphere. To further improve the reliability, the
air cell in the bladder are connected with exterior atmosphere
through silica gel breather.