يبدو أنك لست عضوًا في TradeKey.com بعد. اشترك الآن للتواصل مع أكثر من 7 مليون مستورد ومصدر عالميًا.
انضم الآن ، مجانًا |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
AX 210 Advanced Lightning Protection System for 130 mtr protection
Next

AX 210 Advanced Lightning Protection System for 130 mtr protection

|

5 Rod Minimum Order

بلد:

Turkey

نموذج رقم:

LAP AX210

سعر فوب:

أحصل على آخر سعر

الموقع:

-

سعر الحد الأدنى للطلب:

-

الحد الأدني للطلب:

5 Rod

تفاصيل التغليف:

Export Standards

موعد التسليم:

15 Days

القدرة على التوريد:

-

نوع الدفع:

Western Union, L/C, T/T

مجموعة المنتج :

الاتصال الآن
عضو مجاني

الشخص الذي يمكن الاتصال به Mr. Faruk

Kemal Reis Cad. No: 19/1 Gaziemir , Izmir, Izmir

الاتصال الآن

الوصف

Active ESE early streamer emission air terminal SABO LIVA LAP AX-210 in accordance with latest NFC 17-102 2011 standard.

· Shaft GI/FRP/SS for raising air terminal minimum 3 m above the top of the structure to be protected

· Down conductor  25*2 mm copper strip

· Lightning counter of 6 digits IP65

· Test Link for disconnecting the down conductor and testing the earthing

· Earthing should be maintenance free tripod type of copper bonded steel rod

Specifications:

· Very high grade stainless steel material body, 1000mm long and 5 Kg nett weight with pointed tip

· Based on active early streamer emission principle and consists of ion generator

· Early streamer warning time of 82 MICROSECONDS

· Protection radius at 4 m height in Level IV area is 130 m

· METU electrical & electronics test report as per NFC 17-102 standard

· In each lightning conductor serial number, model no., CE mark, hologram & manufacturer name is available. Packed inside printed carton for each piece

· Every lightning conductor carry 30 years warranty. Certificate is issued from the manufacturer

· Internal last inspection report of manufacturer will be provided with every serial numbered lightning arrester, if required

· Sigma test report

· CE certification

· Designed as per NFC17-102 standard which meets all lightning conductor standards

· Suitable for all types of lightning discharges (negative, positive or lateral)

· No use of battery or power source is required

· Tested for 115 KA short circuit in HV test lab, triggering time and temperature -40 to +125 degree centigrade.image

بلد: Turkey
نموذج رقم: LAP AX210
سعر فوب: أحصل على آخر سعر
الموقع: -
سعر الحد الأدنى للطلب: -
الحد الأدني للطلب: 5 Rod
تفاصيل التغليف: Export Standards
موعد التسليم: 15 Days
القدرة على التوريد: -
نوع الدفع: Western Union, L/C, T/T
مجموعة المنتج : Lightning Rod

Send a direct inquiry to this supplier

إلى:

Mr. Faruk < Liva Grup Elektrik Elektronik Insaat.Taah. San.ve Tic.Ltd.Sti. >

أريد أن أعرف: