يبدو أنك لست عضوًا في TradeKey.com بعد. اشترك الآن للتواصل مع أكثر من 7 مليون مستورد ومصدر عالميًا.
انضم الآن ، مجانًا |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
Procalcitonin (PCT) Test Kit (Fluorescence Immunochromatography)
Next

Procalcitonin (PCT) Test Kit (Fluorescence Immunochromatography)

8 ~ 15.5 /

|

1000 Minimum Order

بلد:

China

نموذج رقم:

-

سعر فوب:

8 ~ 15.5 / أحصل على آخر سعر

الموقع:

Hangzhou, China

سعر الحد الأدنى للطلب:

8

الحد الأدني للطلب:

1000

تفاصيل التغليف:

Box packing with bag packing inside

موعد التسليم:

7-15days for air transfering

القدرة على التوريد:

5000 Piece per Day

نوع الدفع:

Other, Western Union, T/T

مجموعة المنتج :

-

الاتصال الآن
4th عام

الشخص الذي يمكن الاتصال به Ms. Bette

Hangzhou, Zhejiang

الاتصال الآن

مواصفات المنتج

  • Method:Fluorescence immunochromatography
  • Specimen:Whole blood, Plasma, Serum
  • Specification:10 tests/box, 20 tests/box, 25 tests/box, 30 tests/box, 50 t
  • Components:Each bag contains a test card and a desiccant
  • Test time :10 mins
  • Certification:CE

الوصف

Procalcitonin (PCT) Test Kit
(Fluorescence Immunochromatography)
 
1.Introduction
Procalcitonin (PCT) is the prohormone of calcitonin (CT), which is generally less than 0.1 ng/mL in the blood of healthy people, and its secretion increases after being stimulated by pro-inflammatory responses, especially after bacterial infection. Procalcitonin is an important marker that can specifically distinguish bacterial infection from inflammatory response caused by other reasons. Viral infection, allergy, autoimmune disease and transplant rejection do not cause significant elevation of procalcitonin, while local bacterial infection can result in moderate elevation of procalcitonin concentrations. In some cases (neonatal, multiple trauma, burns, major surgery, prolonged or severe cardiogenic shock), the elevation of procalcitonin may not be related to infection and usually returns to normal values quickly.
PCT is an ideal indicator for the auxiliary diagnosis of severe bacterial infection and septicopyemia, sepsis and other diseases, and has high sensitivity and specificity for systemic bacterial infection, septicopyemia, sepsis, etc.
 
2.Indications for Use
The test kit is used for the quantitative determination of procalcitonin (PCT) in human serum, plasma or whole blood samples in vitro.
 
3.Who Should Have Procalcitonin (PCT) Test?
Vulnerable groups are infants and newborns, the elderly, patients with a history of serious diseases such as severe infection and severe burns, patients with impaired immune system, and tumor patients. Symptoms are like recurrent chills, high fever, petechiae rash, arthralgia of large joints, hepatomegaly. These people are suggested to have a Procalcitonin (PCT) Test.
 
4.Singclean Advantage
1) Accuracy: The recovery rate is between *5% and **5%.
2) Rapid:Just need *0 min to get the results
3) Easier to read:based on fluorescence immunochromatography, easier to read test result than colloidal gold immunochromatography.
4) Convenient Storage: The kit can be stored at room temperature or refrigerated (***0°C)
5) Longer validity period:*8 months of validity period.
 
5.Product Performance Index
a) Linear range: within the linear range of 0.1ng/mL ~**0ng/mL, the linear correlation coefficient r0.***0;
b) Blank limit: not higher than 0.*5ng/mL;
c) Precision
In-batch precision: The coefficient of variation (CV) is not more than *5%;
Precision between batches: The relative range between batches is not more than *5%
 
6.Product Information
 
Product Name Procalcitonin (PCT) Test Kit
Method Fluorescence immunochromatography
Specimen Whole blood, Plasma, Serum
Specification *0 tests/box, *0 tests/box, *5 tests/box, *0 tests/box, *0 tests/box, **0 tests/box.
Components Each bag contains a test card and a desiccant; the test card is composed of a t shell and a test strip, and the test strip consists of a sample pad, a fluorescent pad (fixed with fluorescently labeled PCT monoclonal antibody 1), nitrocellulose membrane (coated with PCT monoclonal antibody 2 and goat anti-mouse IgG), filter paper and PVC plastic plate
Test time *0 mins
[Applicable instrument]
Fluorescence immunoassay analyzer
It should be purchased separately and can be used for different Test Items, like CK-MB, IL6, PCT.
 
7.Sample Requirements
1. Human serum, plasma or whole blood samples; other body fluids and samples may not give accurate results.
2. Venous blood or fingertip blood should be collected under sterile conditions. It is recommended to use human serum or plasma for testing.
3. Anticoagulation with EDTA, sodium citrate or heparin is recommended for plasma and whole blood samples.
4. After the clinical blood samples are collected, the test must be completed within 4 hours at room temperature; serum and plasma can be stored at 2~8°C for 3 days and stored below **0°C for 5 months. Whole blood samples should not be frozen and stored at 2~8°C for 3 days. Avoid heat inactivating samples, and hemolyzed samples should be discarded.
5. Samples must be returned to room temperature before testing. Cryopreserved samples need to be completely thawed, rewarmed, and evenly mixed before use. Do not freeze and thaw repeatedly.
 
8.Test Procedure:
a) Bring the test kit and sample to be tested to room temperature.
b) Make sure the ID card matches the batch number of the kit, and insert the ID card into the card reading area of the instrument to read the information.
c) Open the inner package of the test card, take out the test card; draw *0μL of serum plasma sample, drop vertically to the test card sampling place, and start timing; draw *0μL whole blood, vertically drop it to the test card sampling place, and immediately add 1 drop whole blood diluent at the sample adding place and start timing.
d) After adding the sample, click "Start Test" on the screen of the fluorescence immunoanalyzer, and the test card will react at room temperature for *0 minutes; insert the test card into the test card slot of the fluorescence immunoanalyzer, and the instrument will automatically test the test card; The test results can be seen on the display screen of the immunoassay analyzer. Click "Print" on the screen to print the results.
 
9.Interpretation of Results:
(for reference only, not used as clinical diagnostic criteria, test results need to be combined with other clinical and laboratory data for clinical diagnosis)
 
PCT mass concentration (ng/mL) Clinical significance
<0.*5 Normal value
<0.5 No or mild systemic inflammatory response. May be local inflammation or local infection.
0.**2 Moderate systemic inflammatory response. Infection may be present.
***0 Most likely sepsis, severe sepsis, or septic shock. There is a high risk of organ dysfunction.
≥*0 Almost all severe bacterial sepsis or septic shock. Often accompanied by organ failure, there is a high risk of death.
 
*0.Limitation
a) This kit is only for the test of human serum, plasma or whole blood samples. Abnormal hematocrit samples have an impact on the results of the whole blood test. The test results of serum, plasma and whole blood are not significant difference when the hematocrit is between *1% and *8%.
b) The test results need to be combined with other clinical and laboratory data, and if the PCT test results do not match the clinical assessment, further testing is required.
c) False positive results may be caused by: cross-reaction of antibody-like components in the blood; some nonspecific components in blood have similar antigenic determinants to capture fluorescent-labeled antibodies.
d) Hemoglobin, triglycerides and bilirubin in the blood sample can interfere with the test results, where the maximum allowable concentrations are 5g/L, *0g/L and 0.2g/L, respectively.
e) False negative results may be caused by: some unknown components shield the antigenic determinants from binding to the antibody; the unstable PCT antigen gradually degrades with time and temperature and cannot be recognized by the antibody. Valid test results depend on a good reagent and sample storage environment.
f) Other factors may also cause errors in test results, including technical reasons, operational errors and other sample factors.
*0. Certification
CE

بلد: China
نموذج رقم: -
سعر فوب: 8 ~ 15.5 / أحصل على آخر سعر
الموقع: Hangzhou, China
سعر الحد الأدنى للطلب: 8
الحد الأدني للطلب: 1000
تفاصيل التغليف: Box packing with bag packing inside
موعد التسليم: 7-15days for air transfering
القدرة على التوريد: 5000 Piece per Day
نوع الدفع: Other, Western Union, T/T
مجموعة المنتج : -
Procalcitonin (PCT) Test Kit (Fluorescence Immunochromatography)

Send a direct inquiry to this supplier

إلى:

Ms. Bette < Hangzhou Singclean Medical Products Co., Ltd. >

أريد أن أعرف: