يبدو أنك لست عضوًا في TradeKey.com بعد. اشترك الآن للتواصل مع أكثر من 7 مليون مستورد ومصدر عالميًا.
انضم الآن ، مجانًا |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
Sell split core current transformer

Sell split core current transformer

|

Minimum Order

Place of Origin:

-

Price for Minimum Order:

-

Minimum Order Quantity:

100

Packaging Detail:

-

Delivery Time:

-

Supplying Ability:

200000

Payment Type:

-

الاتصال الآن
عضو مجاني

الشخص الذي يمكن الاتصال به Ms. sindy

NO.219,ChengJiang Road, Wuxi, Jiangsu

الاتصال الآن

Description

• Rated Current *0A, **0A, **0A, **0A, **0A, **0A • Output of 0.**3 Volt at rated current • Accuracy: ± 1% from *0% to **0% of Full Scale Range • Phase angle < 2 º maximum at *0% rated current[For ASC****0 & ASC****0, phase angle <1 º maximum at *0% rated current] • Snap closing/opening feature. • Shrouded core blades for protection during installation. • Core interleaved at joints for accuracy. • No exposed metal parts on assembled transformer. • Internal precision burden resistor across secondary. • Epoxy encapsulated housing. • Accuracy is measured from *0% to **0% of rated current. • Phase angle is measured at *0% of rated current Outlines Aï&frac*4;š*1MAX Bï&frac*4;š*4.5MAX Cï&frac*4;š*6.5MAX Dï&frac*4;š***0MAX Eï&frac*4;š*6±0.5 Dimensions (mm) *0.8 *4.2 *6 ***0 *6 *0.5 *4 *6.3 ***0 *6 *1 *4.2 *6.2 ***0 *6 • Applications: Split-core current transformers has been designed to meet the growing demand for installation into existing networks. The Split-core allows installation without disconnecting cables or busbar circuits. The products are ideal for retro-fitting and are therefore popular in the Energy Management Systems, Ammeters, Watt-hour meters, Instrumentation, Relays, Panel meters, Varmeters, Power Factor Meters, Switch boards, Panel boards, Control boards and Power Factor correction industries, etc • Opening style CTs with internal built-in burden resistor provides safety, **3mV AC output proportional to current. All current probes come pre-wired to a terminal block that plugs into the **3 mV module (VAC****3) which must be used with the Ammeters, Watt- hour meters, Varmeters, power factor meters, relays unit for current measurements. Accuracy for all split-core current probes: ± 1% from *0% to **0% of full rated current. • The CTs could have burden resistors or Zener across the secondary, as per customer&#**9;s demands

Send a direct inquiry to this supplier

إلى:

Ms. sindy < JiangYin Spark Electronic Technology Co., Ltd >

أريد أن أعرف: