Major Features

â– Integrated with SpO2 probe and processing display module
■Small in volume、light in weight and convenient in carrying
â– Operation of the product is simple, low power consumption
â– SpO2 value display
â– Pulse rate value display, bar graph display
â– Pulse waveform display
â– The display mode can be changed
â– With measured data overruns limits and low-voltage alarm function
â– Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage
â– Automatically power off function: when the device is under the state of measuring interface . it will automatically power off within 5 seconds if the finger falls out of probe
â– Display format can be saved after power off
â– Small appearance,more fit for children

Main performance

Display Mode: 0.*6"Dual-color OLED display
Screen Resolution: **8**4
SpO2 Measuring Range: 0%~**0%, (the resolution is 1%).
Accuracy: *0%~**0%: ±2% ,Below *0% unspecified.
PR Measuring Range: *0bpm~**0bpm, (the resolution is 1bpm)
Accuracy: ±2bpm or ±2% (select larger)
Measurement Performance in Weak Filling Condition:
SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
Resistance to Surrounding Light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.
Power Consumption: less than *0mA
Voltage: DC 3.6V~4.2V
Power Supply: Voltage 3.6 rechargeable lithium battery × 1 
Battery Working Hour: 6 hours
Battery working life: Charge and discharge no less than **0 times.
Safety Type: Interior Battery, BF Type

Accessories

Sell in standard:
â– A hanging rope
â– A user manual
â– One rechargeable buttony lithium battery
â– Charge accessories: One power adapter, one charger, one data line

Physical Identity
Dimension: *6(L) × *0(W) × *9(H) mm
Weight: About *5g (with a rechargeable buttony battery)