FOB Price
أحصل على آخر سعر|
Minimum Order
Place of Origin:
Shenzhen(China)
Price for Minimum Order:
-
Minimum Order Quantity:
30 Millimeter
Packaging Detail:
100m/roll.200m/roll, 300m/roll , or you require
Delivery Time:
within 15days after deposit
Supplying Ability:
1500 Roll per Day
Payment Type:
Other, Western Union, L/C, T/T
الشخص الذي يمكن الاتصال به Ms. Vivi
A1104 Tian anCyberPark,Qinglin Road Longgang District,, Shenzhen
The standards
The power cable is mainly complying with IEC ****2 standard, also can be produced according to OEM requirements and other standards, such as BS, DIN, ASTM, VDE, NFC standards, and so on.
The construction of the power cable for different voltage grade
1 low voltage cable power cable
Low voltage (0.6/1 kv)
single core or multi-core
copper or aluminium conductor
pvc inusulation
steel tape armored or galvanized steel wire armored or unarmored
pvc outer sheath
power cable.
2 medium voltage cabel power cable
Voltage grade is up to *5kv,
cross-section area can be up to ***0 sqmm (copper or aluminiun conductor).
Conductor long-time operating temperature is *0 degrees.
In short circuit, conductor highest temperature should be not more than **0 degrees.
1kv**5 kv
multi-cores
copper or aluminium conductor
xlpe insulation
copper tape or copper wire screen
galvanized steel wire armored
pvc or pe sheath
power cable
3 high voltage cable power cable
High voltage (*5kv~**0kv)
copper or aluminium conductor
xlpe insulation
metal sheath (lead or corrugated aluminium)
hdpe or pvc outer sheath power cable.
Laying conditions: for lyaing under ground with large different altitude, be able to bear external machanical force and moderate pulling force.
The power cable's characteristic:
3.1 long time operating temperature for cable conductor is *0 degrees.
3.2 the highest temperature of the conductor in short circuit (no longer than 5 seconds) in not more than **0 degrees,
if a joint is in the cable, the temperature of the tinning welding joint is not more than **0 degrees, compressing joint not more than **0 degrees and electro-welding joint not more than **0 degrees.
3.3 no drop in limited provided there is full mechanical tention when cable is laid. It si forbidden to lay cable in iron-pipe or to fix cable by circling around the cable with iron materials.
3.4 being laid, the minimum temperature of the cable shall not be lower than zero degree. In the case of lower temperature, heating measures shall be taken.
We can also supply the OEM and customized products according to your request