BPM-9010  Multi-Parameter Patient Monitor

BPM-9010 Multi-Parameter Patient Monitor

( Negotiable )

|

Minimum Order

Place of Origin:

shenzhen

Price for Minimum Order:

-

Minimum Order Quantity:

1 Piece

Packaging Detail:

box

Delivery Time:

3days

Supplying Ability:

50 Perch per Day

Payment Type:

T/T, L/C, PayPal

الاتصال الآن
عضو مجاني

الشخص الذي يمكن الاتصال به Mr. ANKE

4/f,Block 210,2nd industrial area of Nanyon,Nanshan Dist., Shenzhen, Guangdong

الاتصال الآن

Description

BPM****0Multi-Parameter Patient Monitor
 
*2.1''high resolution color TFT display
*6 hours trend graphic data, **-lead ECG analysis
Arrhythmia and S-T segment analysis
Anti-defibrillation, Anti-high frequency electrotome
Multi-language,easy operate,durable and stable
Calculation function of drug concentration , drug titration and hemodynamic status   
Wired or wireless network   
Three-level Audible and visible alarm,events recallable , Nurse Call function
AC/DC power supply, built-in high capacity battery
 
Standard configuration: ECG,RESP,NIBP,SPO2,PR,TEMP
Optional function: IBP,EtCO2,Cardiac output,printer
 
 
Specification:
Dimension:                   **2(H) X **7(W) X **5(D) (mm)
Weight:                         6.5Kgs (with battery)
 
ECG
Measuring range:              Adult   0~**0bpm     
Neonate and pediatric   0~**0bpm
Band width:                  0.*5Hz~**0Hz
Accuracy:                 ±1%
Lead Type:                *-lead and *-lead selectable
Lead selection:             standard I,II,III; augmented limb lead
                         aVR, aVL, aVFï¼›Chest lead V1~V6
Resolution:               1 bpm
Trend monitoring time:no less than *6 hours
ST-Segment analysis:       *2.0 mV ~2.0mV; auto
Arrhythmia analysis:       *3 kinds of Arrhythmia analysis
Scanning speed:            *2.5, *5, *0mm/Second
Gain selection:             x1/2, x1, x2; auto
Protection:                Withstand ***0 VAC/ *0Hz voltage
                                     Voltage in isolation against
                                     Defibrillation and electrosurgical
                                     interference
ECG cable :                adults, pediatric and neonate
Alarm Range:               *****0 bpm
ARR Alarm:                Audible and visible alarm,
                                     events recallable
 
NIBP
Method:                    Automatic Oscillometric
Operation Model:             manual, automatic, continuous 
Auto measurement
time interval:                Adjustable 1 /2 /3/4
                                     /5/*0/*5/*0/*0/*0/**0/**0/**0 Min.
Measuring Unit:              mmHg /kPa selectable
Measurement types:           Systolic, Diastolic, Mean
Measuring Range:            Adult:     *0~**0mmHg
                                     Pediatric:*0~**0mmHg
                                     Neonate: *0~**5mmHg
Cuff pressure range :          0~**0mmHg
Cuff type:                   Adult cuff (standard)
                                     Pediatric and Neonate(Optional)
                                     Pediatric and Neonate(Optional)
Cuff inflation time:           < *0 seconds
Cuff deflation time:           <*0 seconds 
Over-Pressure
Protection:                  Yes
Alarm:                     Upper alarm,lower alarm,Auto-memory
 
TEMP
Measuring range:            0~ *0 ℃ ( *2~**2℉ )
Probe Type:               Body temperature probe (standard)
                                     Esophageal temperature probe(Optional)
                                    Rectal Temperature probe (Optional)
Resolution:                  0.1℃
Accuracy:                   ±0.1℃
Channel:                    Dual-channe,Provide T1, T2
Alarm Range:                0~*0℃
 
SpO2
Measuring range              0~**0%
Resolution:                  1%
Accuracy:                   ±1% ( *0%~**0%)
                           ±2% (0%~*9% )
PR measuring range:          0~**5 bpm
PR accuracy:                ±1 bpm
Sensor Type:                Adult sensor (standard)
                                     Pediatric sensor(optional)
                                     Neonate sensor(optional)
Alarm Range:                0~**0%
 
RESP
Display:                    waveform display and numeric display
Operation Mode:             Auto/Manual
Method:                   Trans-thoracic impedance
RR Measuring range:          0~**0bpm
Accuracy:                    ±1 bpm
Apnea alarm threshold: *0s,*5s,*0s(default),*5s,*0s,*0s
Band Width:                 0.**2.5Hz (*3dB)
Sweep speed:                6.*5mm/s,*2.5mm/s,*5mm/s,*0mm/s
Alarm Range:                Adult:****0rpm
                           Pediatric and Neonate:****0rpm
 
IBP (Optional)
Measurement range:           - *0 ~ **0 mmHg
Channel:                    2 channels
Sensitivity:                  5 μ V/V/mmHg
Impedance range             **0~***0Ω
Accuracy:                   ±1 mmHg or ±2%
                           (exclusive of transducer)
Alarm Range:                **0 ~ **0 mmHg
 
EtCO2 (Optional)
Measurement range:          0 ~ **0 mmHg
Accuracy:                  1rpm
Sample flowerate:            *0 ml/min
Sample rate accuracy         ±*5% or *5 ml/min.
Respiration rate:             0 ~ **0 rpm
Respiration accuracy:         ±2 rpm (0 ~*0 rpm)
                         ±5 rpm (>*0 rpm)
Respiration time:            ï¼œ *0 ms
Delay time:                ï¼œ2s

Send a direct inquiry to this supplier

إلى:

Mr. ANKE < Shenzhen Bestman Instrument >

أريد أن أعرف: