FOB Price
أحصل على آخر سعر( Negotiable )
|Minimum Order
Place of Origin:
Baoding,Hebei,China
Price for Minimum Order:
-
Minimum Order Quantity:
1 Piece
Packaging Detail:
Wooden box
Delivery Time:
45 days
Supplying Ability:
55 Piece per Day
Payment Type:
T/T, L/C
الشخص الذي يمكن الاتصال به Yolanda
No.5699,North 2nd ring road, Baoding, Hebei
1.About us:
Baoding Tianwei Hengtong Electric Co., Ltd is a one of leading manufacture in China specialize in NER or NGR neutral grounding equipments for electrical system.
2. Purpose:
THT-FZG Neutral Grounding Resistors Enclosure is a complete set of equipment specially used for the power generator’s neutral point adapts the high resistance grounding.
3.Design principle:
The arc grounding over-voltage occurs when the Generator main circuits have a high earth fault current. While the generator usually capable of loading low withstand voltage and easier to damage. The generator coil will sever burns if the earth current is too high. The –FZG type generator neutral grounding resistor is the most popular and safe in the practice by high resistance connecting to the earth.
4.Site condition:
(1) Ambient temperature: **0°C~*0°C
(2) Altitude: less than ***0m
(3) Relative humidity: less than *5% (*5°C)
(4) Rated frequency: *0/*0HZ
5.Properties:
(1) Material of enclosure: stainless steel or aluminum zinc plate with high corrosion-resistance.
(2) Intellect controlled unit: monitor the unbalanced current, the resistor plate, the grounding transformer and the enclosure temperature, It can also transmit the earth fault information to the controlling room.
6.Normal Parameter Table
Voltage Grade | Single- phase grounding transformer | Single- phase grounding capacity | Outer-shape dimensions |
*0.5 | *0.5/0.*3KV | Below *0 | ***0 x***0 x H (height of cubicle depends on flange) |
*3.8 | *3.8/0.*3KV | ||
*5.*5 | *5.*5/0.*3KV | ||
*0 | *0/0.*3KV | ||
*4 | *4/0.*3KV | ||
*0.5 | *0.5/0.*3KV | ****0 | ***0 x***0 x H (height of cubicle depends on flange) |
*3.8 | *3.8/0.*3KV | ||
*5.*5 | *5.*5/0.*3KV | ||
*0 |
*0/0.*3KV |
||
*4 |
*4/0.*3KV |
||
*0.5 | *0.5/0.*3KV | ****0 | ***0 x***0 x H (height of cubicle depends on flange) |
*3.8 | *3.8/0.*3KV | ||
*5.*5 | *5.*5/0.*3KV | ||
*0 |
*0/0.*3KV |
||
*4 |
*4/0.*3KV |
7.When order, please supply:
(1) the rated voltage, capacity and capacitive reactance of the system;
(2) the type of the grounding transformer;
(3) whether needs zero sequence current transformer, and its transformation ratio and capacity?
(4) material of the enclosure, IP protectional grade, the color, installing place and the line mode.