FOB Price
أحصل على آخر سعر950 ~ 880 / Piece
|Minimum Order
Place of Origin:
china
Price for Minimum Order:
Minimum Order Quantity:
1 Piece
Packaging Detail:
40*28*38
Delivery Time:
2weeks
Supplying Ability:
500 Piece per Week
Payment Type:
T/T
الشخص الذي يمكن الاتصال به selena
Shenzhen, Guangdong
Features:
*2.1'' TFT Big-screen, real-color, wide-visual-angle and
high-brightness LCD display, Chinese-English language
interface;
Can monitor the main waveforms of standard synchronous *-lead and **-lead,analyze on ST segment to facilitate diagnosis for doctors, choose the source of three kinds of Heart Rate, have waveform-filling and *-min cardiac electric replay function, measure synchronous many kinds of standard regular parameters, pulse conducting time and cuff pressure, and save the integrate patient information and review the monitoring-record;
With the formed by network, bed-side machines and central multi-parameter monitor system, constituting the web of monitoring and trend-data display and **6 hours trend review;
With standard six-parameter monitoring, adding single/double IBP, Et CO2(side stream),monitoring fetal function to provide accurate quickening and TOCO;
With manual printing and alarm trigger printing functions available, and able to use together with high-frequency electrical cutter and defibrillator.
Specifications:
1.Safety level
Class I anti-electroshock equipment, ECG(RESP), TEMP*-Type CF,
SPO2, NIBP*-BF
2. Power supply
AC ******0V , *0/*0Hz, Pmax=*0VA, FUSE 0.5A
3. Display
True color,*2.1'' type LCD, resolution **0x**0
4. Signal interface
External display interface: standard VGA
External communication interface: RS***5
External print interface: standard combining-port
5. Recorder
Recording width: *8mm
Paper speed: *5mm/s
Trace: 3 channel
6. ECG
specifications:
Lead mode:*2 leads (R,L, F, N, C1, C2, C3, C4, C5,
C6)
Lead selection: I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6
Waveform:*2 channels
Gain: ×0.5, ×1.0, ×2.0
Modes: diagnosis, monitoring, operation
Input impedance:>5MΩ
CMRR: >*0dB
Electrode offset potential: ±**0mV
Leakage current :<*0μA
ECG signal range: ±*0mV(Vp-p)
Frequency response (bandwidth):diagnosis 0.*****0Hz
Monitoring: 0.***0Hz
Operation: ***0Hz
Measurement range: *****4bpm
Resolution: 1bpm
7. RESP
specifications:
Method: Impedance between RA-LA
Input impedance: >2.5MΩ
Bandwidth: 0.**2Hz
Resp rate: ****0rpm
Measuring Range: ****0rpm
Resolution: 1bpm
8. NIBP
specifications:
Method: oscillation
Mode: manual, periodic, continuous
Measuring interval in periodic mode: 3, *0, *5, *0 min
Continuous mode: 5 min
Pulse rate range: *****0bpm
Overpressure protection: adult **0 mmHg child **5 mmHg
9. SPO2
specifications:
Measuring range: ****0%
Resolution: 1%
Actualization interval: 1sec
Alarm delay: *0 sec
Pulse rate: measuring range: ****4bpm
*0. TEMP
Specifications:
Measuring range: ***0℃
Resolution: 0.1℃
Actualization interval: 1sec
Average time constant: <*0 sec
Packaging
collocation:
Packaging Dimension: *0cm x *8cm x *8cm
Gross weight:*2kg
Normative collocation: **0V power cable 1pcs, BPM****0 six-parameter, BPM****0A six-parameter+ printer, BPM****0B six-parameter+printer+EtCO2, BPM****0C six-parameter+printer+single fetal monitor