Description
Technical Data at a Glance:
Standards and specifications: Type-tested
low-voltage switchgear and controlgear assembly (TTA), Protection
against electrical shock, testing of response to internal faults
(arcing faults)
Rated operational voltage: up to
**0V,
Rated insulation voltage:
***0V,
Rated impulse with stand voltage:
8kV,
Rated current: up to ***0A,
Rated impulse withstand current: up to
**0kA
Rated short-time withstand current: up to
**0kA
Internal separation: forms 1 to
4,
Surface treatment: frame parts- Sendzimir
galvanized, enclosure-sendzimir galvanized/powder-coated,
doors-powder-coated
Degree of protection: IP*0 to IP
*4,
Dimensions: height****0mm,
width***0,**0,**0,**0,***0mm, depth***0, **0, ***0,
***0mm,
SIVACON can accommodate up to *0 feeders
per cubicle, that’s a world record. Even an initial base area of
**0***0mm can be utilized. Standardized external dimensions
simplify space requirement planning.
SIVACON is completely communicative with
the components DP/3WN1, DP/*3WN6,SIMOCODE-DP as well as AS-I, via
PROFIBUS-DP SIVACON executes all control commands reliably and
supplies all required diagnostic and operating data to the process
control level.
TTA-tested standard modules: Verified
safety for every specifically designed switchboard
installation.
Solid-wall design: Safe pressure
equalization in the event of an arcing fault.
Spring-loaded locks for front doors and top
cover with pressure relief flaps: Personnel safety, safe pressure
equalization in the event of an arcing fault.
Circuit-breaker design, withdrawable-unit
design, test and disconnected position with door closed: Ensure
plant safety, personnel safety and improved availability. Degree of
protection of switchboard unaffected, prevents dangerous deposits
in the switchboard, reliable contacting of withdrawable units and
protection for operating personnel in the event of internal
faults.
Withdrawable-unit design and visible
isolating gaps: Visible isolating gaps on incoming/outgoing side,
safe to work on withdrawable unit, on cable connection and on
loads, and constant isolating gap condition.
Withdrawable-unit design and standard
operator interface with operating error protection for all
withdrawable units: No maloperations and less time required for
instruction.
Withdrawable-unit design and isolating
contact system located inside the contours of the withdrawable
units: Protected against damage.
Fixed-mounted design and lateral universal
cubicle busbar: Visible and accessible connections.