FOB Price
أحصل على آخر سعر|
Minimum Order
Place of Origin:
-
Price for Minimum Order:
-
Minimum Order Quantity:
1 Piece
Packaging Detail:
-
Delivery Time:
-
Supplying Ability:
-
Payment Type:
-
الشخص الذي يمكن الاتصال به Zhu
Taicang, Jiangsu
Application:
SSR Series DC solid state relay with flame-retardant plastic case with epoxy resin, with high structural strength, impact resistance, vibration resistance, input. Small can easily input drive current with computer terminals and a variety of digital program-controlled circuit interface, widely used in petrochemical equipment, food machinery, packaging machinery, textile machinery, machine tools, plastics machinery, fitness equipment, recreational facilities and other automation control fields.
Especially suitable for corrosion, moisture, dust, and other harsh environments requires proof, and the frequent switching of the occasion. AC contactor is updated alternative.
|
|
Input Parameters |
|
Control voltage |
***2VDC |
Control current |
AC:*2mA |
Product Type |
SSR*2DD-P |
Output parameters |
|
Load current |
2A |
Load voltage |
*****0VDC |
State leakage current |
≤*0mA |
Buck-state |
≤1.8VAC |
Off time |
≤*0mS |
Dielectric Strength |
***0VAC |
Insulation resistance |
***0MΩ/**0VDC |
Ambient temperature |
**0°C-**5°C |
Installation |
Circuit board mounting |
Work instructions |
No |
Weight |
*0g |
Safety Precautions:
1, the load current is higher than *0A must be used when installed in the radiator or cooling effect with the corresponding metal base plate, and solid-state relay heat between the base plate and mounting surface coated with thermal grease, *0A more plus fan forced cooling or water cooling.
2, using the AC inductive load, high transient voltage and surge current is applied to the output side, which may cause the solid state relay conduction or damaged, often need to access a specific output voltage clamping voltage control devices, such as double Zener diode or varistor (MOV). Varistor recommended to take the rated voltage of 1.**1.9 times;
3, close to the minimum load current is controlled by a smaller current load, it should be parallel with the load a dummy load resistor to reduce output leakage current at the load produces higher residual voltage.
4, in order to avoid the rise of solid state relays exceed the allowable value, the cooling effect should be considered in the design and application installation location, only when two or more solid-state relays mounted side by side, you should leave appropriate spacing.
5, more than just the output terminal of the solid state relay may be used in parallel, in an attempt to increase the output current. But the output can be used in tandem in order to apply a higher operating voltage.
6, when using more than just sharing a solid following the control power, the input which can be used in tandem can also be used in parallel.
7, the capacitive load caution this piece, please select the capacitive load dedicated solid state relays.