Sell Sell Online pH meter for Aquarium, water tester, PH tester

Sell Sell Online pH meter for Aquarium, water tester, PH tester

40 ~ 50 / Piece ( Negotiable )

|

Minimum Order

Place of Origin:

China

Price for Minimum Order:

Minimum Order Quantity:

10 Piece

Packaging Detail:

1pc in box, 20pcs in carton

Delivery Time:

30days

Supplying Ability:

1000 Piece per Week

Payment Type:

T/T, Western Union, PayPal

الاتصال الآن
عضو مجاني

الشخص الذي يمكن الاتصال به Ms. Enya

Mingfa commercial center, Xiamen, Fujian

الاتصال الآن

Description

pH***1 pH meter aquarium online

Product Specifications
Range : pH: 0.*0 ~ *4.*0pH
Temperature : **0 ℃ ~ *0 ℃ (**8 ℉ ~ **8 ℉)
Resolution : pH: 0.*1pH
Temperature : 0.1 ℃ (0.2 ℉)
Accuracy : pH ± 0.1pH
Temperature ± 1.0 ℃ (± 2.0 ℉)
Power supply : DC 6V ( can be equipped with power adapter )
Automatic shutdown : 6 minutes
Temperature Compensation : 0 ℃ ~ *0 ℃
Operating temperature : 0 ℃ ~ *0 ℃
Size : *5mm × *5mm × *8mm
Weight: *0 g

Procedure
1 Remove the electrode protective cover, will PH electrode into the electrode \'s BNC connector socket .
2 Rinse the electrode with distilled water and dry with filter paper attached to the electrodes of the water.
3 Touch the " " switch boot, tap "℃ / ℉" key to switch to Fahrenheit Celsius .
4 pH meter electrode into the test solution and gently stir until the numerical stability , read the display ( NOTE: The display on the row for the pH value , the lower the temperature value ) .
5 After use, clean the electrode , touch " " switch off , put the electrode protective sleeve.

pH calibration
1 . The pH electrode into a pH of 6.*6 ( the temperature at *5 ℃) standard mixed phosphate buffer solution, gently shake the electrode .
(2) with a small screwdriver to adjust the potentiometer until the display value and the standard buffer solution at ambient temperature pH values.
3 . The pH electrode immersed in pH4.*1 phosphorus or potassium hydrogen phthalate standard pH9.*8 borax buffer solution , gently shake the electrode .
4 shows the pH value of the buffer value is compared to the error should be within the allowable range .

Precautions
In the following cases , the instrument must be recalibrated .
After calibration has been used ( or place ) for a long time
Frequent use of special electrodes
Accuracy requirements are relatively high .

Battery Installation
If the backlight brightness decreased, measurement error is larger or appear blurred , replace the battery. When replacing the battery , pull out the battery to replace the small cover sheet , note the battery polarity. For long-term monitoring , connect the power adapter.

Warranty
The instrument from the factory on the date one year warranty, guarantee the production and material defects caused . But if the insurance period, the instrument needs repair or replacement , and the cause of the damage , not the user\'s carelessness or improper use , please send us the equipment and instructions agent or our company, we have to be maintenance free .
Ë™ digital display with backlight
Ë™ 6 minutes automatic shutdown