Description
gas vortex flowmeter series is mainly used for medium industrial
pipe fluid flow measurement of steam, steam vortex flowmeter
features low pressure loss, measuring range, high precision in the
measurement conditions are not nearly the volume density of the
fluid flow , Pressure, temperature, viscosity and other parameters.
No moving mechanical parts, so high reliability and little
maintenance. Long-term stability of the instrument parameters. Gas
flowmeter using piezoelectric stress sensors, high reliability, can
be **0 ℃ ~ ***0 ℃ operating temperature range. With analog
standard signal, but also digital pulse signal output, easily
supporting the use of computers and other digital systems is a more
advanced and ideal flow meter。
1ã€Works
    Triangle set in the steam flow
cylindrical bluff body, alternately from both sides of the bluff
body to generate a regular vortex, this vortex is called Carmen
vortex, as shown, the vortex downstream of the bluff body listed in
the non-symmetrically Order。
The occurrence frequency of the vortex set f, the average flow rate
of the measured medium, the bluff body surface facing the flow
width d, the body of the path to D, you can get the following
relation:
 f=SrU1/d=SrU/md
                    (1)
Where U1 - the average velocity on both sides of the bluff
body,m/s;
Sr*-Strouhal numberï¼›
m*-Segment Area on both sides of the bluff body and the pipe
cross-sectional area ratio
 Pipe volume flowqv为
qv=Ï€D2U/4=Ï€D2mdf/4Sr
                (2)
K=f/qv=[Ï€D2md/4Sr]*1
                 (3)
Where K - the instrument flow coefficient, the number of pulses /
m3(P/m3)。
K addition to the bluff body, the relevant geometry of the
pipeline, but also with the Strouhal number related. Strouhal
number of dimensionless parameters, it is with the bluff body shape
and Reynolds number on Figure 2 shows the cylindrical bluff body of
the Strouhal number and the pipe Reynolds number diagram. The
figure shows that in ReD = 2 × **4 ~ 7 × **6 range, Sr can be
considered as a constant, which is the normal operating range
instrument. When the measurement of gas flow, VSF formula for the
flow meter
Â
(4)
Figure 2 Relationship between Strouhal number and Reynolds number
curve
Where qVn, qV - were under standard conditions (0oC or *0oC,
**1.**5kPa) and the volume of traffic
conditions,m3/hï¼›Â
Pn,P*-Respectively, under standard conditions and conditions for
the absolute pressure,Pa;
Tn,T*-Respectively, under standard conditions and conditions of
the thermodynamic temperature,K;
Zn,Z*-Respectively, under standard conditions and conditions for
the gas compressibility。Â
Can be seen from the above equation, VSF output pulse frequency
signal from fluid properties and composition changes, that
instrument coefficient in a certain Reynolds number range, and only
with the bluff body shape and size of the pipe and so on. But as
the material balance and energy flow in the measurement of mass
flow to be detected, then the flow meter should also monitor the
volume of the output signal flow and fluid density, fluid
properties and composition of the flow measurement or have a direct
impact。
  Gas flowmeter is based on the vortex principle Carmen
Measurement of fluid flow in closed conduits new flow meter. Media
because of its good ability to adapt, without direct measurement of
temperature and pressure compensation can be steam, air, gas,
water, liquid volume flow conditions, with temperature and pressure
sensor measures the standard volume flow and mass flow conditions,
is to cut expenditure Flowmeter ideal alternative。
To improve the high temperature gas flowmeter and anti-vibration
performance, the company recently developed a JGLUG improved vortex
flow sensors, because of its unique structure and selection of
materials so that the sensor at high temperature (**0 ℃), high
vibration (≤ 1g) use of harsh conditions。
In practice, the maximum flow rate is often much lower than the
upper limit of the instrument, as the load changes, the minimum
flow rate and often lower than the lower limit of the instrument,
meters are not working in its optimum operating segment, in order
to solve this problem , commonly used in the measurement at the
reduced diameter to improve the measurement at the flow rate, and
smaller-diameter instrument to facilitate selection of the
measurement instrument, but this must be adjustable means between
adjustable tube and instrument over a length of straight pipe
section *5D to Rectifier, the processing, installation is not easy.
Our company has developed a vertical section of the shape of arc
rectifier LGZ adjustable, with a rectifier to improve the flow and
velocity distribution change multiple roles, its structure, small
size, process tube diameter of only 1 / 3, one made with the vortex
flowmeter Not only do not need to add another section of straight
pipe, you can also reduce the process tube straight pipe
requirements, installation is easy。
   For ease of use, battery-powered local
display type gas flowmeter with high-tech micro-power consumption,
the use of lithium uninterrupted power supply can run more than one
year, saving the cable and display instruments for the procurement
and installation costs, may in Display instantaneous flow,
cumulative flow. Temperature compensation is also a body vortex
flowmeter with a temperature sensor, can measure the temperature of
saturated steam and calculate the pressure, which shows the mass
flow of saturated steam. Temperature and pressure compensation for
a body with a temperature and pressure sensors, gas flow
measurement can be directly used to measure the temperature and
pressure of gas medium, which shows the standard conditions of gas
volume flow。
â—†Measurement medium: gas, liquid, vapor
â—†Caliber caliber cartridge specifications Fa Lanka
choice*5,*2,*0,*0,**0
â—†Flange type caliber choice **0,**0,**0
â—†Flow velocity measurement range of normal measurement range of
Reynolds number 1.5 × **4 ~ 4 × **6; gas 5 ~ *0m / s; liquid 0.5
~ 7m / s
The normal range of liquid flow measurement, gas flow measurement
range shown in Table 2; steam flow range in Table 3
â—†Accuracy 1.0 1.5
◆Measured medium temperature: temperature **5 ℃ ~ **0 ℃
◆High temperature –*5℃~**0℃ **5℃~**0℃
â—†Output signal pulse high voltage output signal low 8 ~ *0V 0.7 ~
1.3V
â—†Pulse duty cycle of about *0%, transmission distance is **0m
â—†Remote signal pulse current 4 ~ *0 mA, transmission distance is
***0m
◆Instrument ambient temperature: **5 ℃ ~ **5 ℃ Humidity: 5 ~
*0% RH*0 ℃
â—†Material stainless steel, aluminum
â—†Power Supply DC*4V or lithium battery 3.6V
â—†Intrinsically safe explosion-proof leveliaIIbT*-T6
Protection IP*5