Description
Products:
LXC***0: for stand-alone automated, controlled
by the remote power signal generators from the start and
stop;
LXC*3X0 / LXC*1X0 series controller uses
**-bit microprocessor and embedded system control technology,
precision measuring *6 parameters, *2 programmable inputs, *5
warning protection parameters, *5 programmable output, a total of
**1 can be configured parameters. Of which **8 can be configured
from the front panel. With LCD graphic display module can display
various engine parameters and generator parameters. Being rapidly
expanded use in multiple areas, such as: small power plants, biogas
power generation, oil power, field engineering, factory, fire
pumps, mobile base stations, and many other fields. Suitable for
gasoline, diesel, natural gas, biogas and other power equipment,
many well-known domestic and foreign enterprises have been widely
supporting applications. Completely replace DSE*1X0 / *2X0 series
controller.
Product performance and features:
1, using **-bit ARM microcontrollers, hardware
integration, high reliability has been further improved;
2, LCD LCD is **8x*4, with backlight, Chinese,
English and other languages ​​optional interface operation, and
can be on-site selection, easy commissioning test
machine;
3, with advanced networking capabilities via
GPRS mobile network and Internet connectivity, the network in any
place can RMON;
4, in particular to provide for the leasing
industry management the perfect solution: leasing out via PC remote
management unit, can monitor all operating parameters (oil
pressure, water temperature, voltage, current, power, etc.), you
can change the configuration at any time to protect the unit
improperly applied, can record **0 detailed fault information,
including: key parameters downtime reasons, when the voltage,
current, power, oil pressure, water temperature, etc., and ready to
be uploaded to the monitoring machine. Another multi-level password
management to facilitate the lease term management;
5, with RS**5 communication interface, using
the MODBUS protocol can achieve "three remote" function;
6, control and protection functions: automatic
diesel or natural gas generator set start / stop, sub-gate (ATS
switch) and perfect protection fault display function;
7, parameter settings: allows users to change
the setting of its parameters, and memory in the internal FLASH
memory when the system is powered down is not lost. Most of the
parameters can be adjusted from the front panel of the controller,
all parameters can have SMS function, you can automatically send an
alarm message to five phone numbers set an alarm when the generator
set, generator sets can also be controlled via SMS and access to
power unit status;
8, using a PC via RS**2 interface adjustments
can also be used to adjust the PC via RS**5 interface;
9, a variety of temperature, pressure, oil
level sensor curves can be used directly, and custom sensor
curve;
*0, a variety of starting conditions (speed
sensor, hydraulic, power generation) optional;
*1, has a history of failure record, real time
clock, timer switch (monthly / weekly / boot once a day and can be
set with or without load) function;
*2, all outputs are relay outputs;
*3, mains overvoltage, undervoltage, over
frequency, under frequency, phase, reverse phase sequence function,
power generation has overvoltage, undervoltage, over frequency,
under frequency, over current, over power, reverse power, phase ,
reverse phase sequence function; three fixed analog sensors
(temperature, oil pressure, level);
*4, two programmable analog sensor can be set
to the temperature or pressure or liquid level sensor;
Specifications:
Operating voltage: DC8.0V to *5.0V continuous
power supply
Total power consumption:
Alternator Voltage Input: *0V AC***0 V AC (ph-N) 3 phase 4
wire
Three-phase four-wire *0V AC***0 V AC (ph-ph)
*-phase *-wire
Three-phase three-wire *0V AC***0 V AC
(ph-N)
Single-phase two-wire *0V AC **0 V AC
(ph-h)
Two-phase three-wire
Alternator Frequency: *0 Hz /
*0Hz
Speed ​​sensor voltage: 1.0 to *0V
(rms)
Speed ​​sensor frequency: maximum
****0Hz
Start relay output: *6Amp controller
supply voltage output
Fuel Relay Output: *6Amp controller
supply voltage output
Programmable relay output 1: *6Amp
controller supply voltage output
Programmable relay output 2: *6Amp
controller supply voltage output
Programmable relay output 3: *6Amp
controller supply voltage output
Programmable relay output 4: *6Amp
**0VAC passive output
Power switch on the relay programmable
relay output 5: *6Amp **0VAC passive output
Mains closing relay programmable relay
output 6: *6Amp **0VAC passive output
Dimensions: **0mm x **2mm
x*7mm
Hole size: **4mm x **0mm
Current transformer secondary current:
Rated: 5A
Working conditions: Temperature: (*5 ~
*0) ° C Humidity: (*0 ~ *0)% RH
Storage conditions: Temperature: (- *0 ~
+ *0) ° C
Protection class: IP*5: when waterproof
rubber ring between the controller and the control panel.
IP*2: When there is no waterproof rubber ring
between the controller and the control panel.
Dielectric strength: Object: in the
input / output / power between
Reference Standard: IEC*******2
Test methods: AC1.5Kv / 1min leakage current
3mA
Weight: 0.*0kg