يبدو أنك لست عضوًا في TradeKey.com بعد. اشترك الآن للتواصل مع أكثر من 7 مليون مستورد ومصدر عالميًا.
انضم الآن ، مجانًا |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
JMA Stager controller

JMA Stager controller

350 ~ 450 / Piece ( Negotiable )

|

Minimum Order

Place of Origin:

-

Price for Minimum Order:

Minimum Order Quantity:

1 Piece

Packaging Detail:

Cartons

Delivery Time:

by express, by air, by ship

Supplying Ability:

20 Piece per Week

Payment Type:

T/T, Western Union, Money Gram

الاتصال الآن
عضو مجاني

الشخص الذي يمكن الاتصال به Ms. Maggie

No.2 Huangcun RD,Tianhe DIstrict,, Guangzhou, Guangdong

الاتصال الآن

Description

~Multiple valve controller_ JMA stager controller_Multi-valve system controller
Multiple valve controller Introduction
Multiple valve controller functions:
â—† Password setting
â—† Calendar
â—† Regeneration stage and regeneration time indication
â—† JMA can be initiated manually or through remote control. Timer initiation and interval initiation are also

Multiple valve controller available.
â—† Manual step by step initiation (only for system commissioning)
â—† Reset function
â—† Stages (**8) and stage duration (*****9 Sec) settings
â—† System working stage indication (Service or regeneration stage indication)
â—† Data protection after power cut: settings and data can be stored for 3 years.
â—† Waterproof and rotproof enclosure

JMA stager controllerMultiple valve controller working principle:
The stager may be manually operated or driven by an electric motor that operated through an adjustable timer or flowmeter program. The stager functions by opening and closing its ports, singly or in combination, in a sequence that fit the need of the system. The positions in the sequence correspond to the number of stager in the process (See chart 1). The port that are opened allow the pressurized fluid to flow to and operate some diaphragm valves, while venting other valves—allowing them to return to their normal positions.
The stagers can use either hydraulic or pneumatic control fluid. Continuous electrical power is not required to maintain the positions of the valves such as in a solenoid operated system. Greatly avoid the system breakdown because of power failure.
All types of complex application can be controlled by stager controller system through correct design and combination of the stagers.
 

~JMA stager controller specifications:
â—† Automatic restoration function
â—† Waterproof enclosure (waterproof and shockproof)
â—† Power supply: **0VAC/*0HZ
â—† Timer initiation setting: any time of the day 7 days one week
â—† 8 stages available with duration from 5 to ***9 seconds for each stage
â—† Manually initiation
â—† Service/regeneration Light indication
â—† Auxiliary signal output

Multiple valve controller Technical figures:
Electrical supply: **0VAC/*0HZ, *0W
Remote control signal: At least 2 seconds/dry contactor
Pressure port size: 1/8G thread
Control fluid: hydraulic or pneumatic (**0μfilter is recommended for the system)
Control fluid pressure: 0.2~0.8MPa
Temperature: 4~*0℃
Enclosure size: **0 mm X **0 mm X **5 mm

Multiple valve controller Applications:

Item ID Typical application
 Stage program
 
JMA **1
 Filter
 Service→backwash→rinse
 
JMA **2
 Co-current regeneration softener
 Service→backwash→brine + slow wash→rinse
 
JMA **3
 Filter
 service→backwash
 
JMA **5
 Counter-current regeneration softener
 Service→backwash→brine + slow wash→rinse
 
JMA **6
 3 tanks filter
 service→1#backwash→2#backwash→3#backwash
 
JMA **7
 4 tanks filter
 service→1#backwash→→→4#backwash
 
JMA **8
 5 tanks filter
 service→1#backwash→→→→5#backwash
 
JMA **3
 2 tanks filter (1service 1 stand by )
 1#service→1#backwsh→2#service→2#backwash
 
JMA **4
 Co-current regeneration water softener
 service→backwash→brine→slow wash→rinse→refill
 
JMA **5
 Co-current regeneration water softener
 service→backwash→brine→slow wash→rinse
 
JMA **6
 Co-current regeneration water softener
 service→backwash→brine→rinse→refill
 
JMA **7
 2 tanks parallel filter
 service→backwash 1→rinse 1→backwash 2→rinse 2
 
JMA **8
 Filter
 service→drain→air flush→backwash→rinse
 
JMA **9
 Brine recycle water softener
 service→backwash→brine→brine+slow wash→brine recycle →rinse
 
JMA **0
 6 tanks filter
 service→1#backwash→→→→6#backwash
 
JMA **1
 7tanks filter
 service→1#backwash→→→→7#backwash
 

 

Send a direct inquiry to this supplier

إلى:

Ms. Maggie < GUANGZHOU JIEMNG WATER TREATMENT EQUIMEN >

أريد أن أعرف: