Tests for Current Transformer:

1 Excitation curve and parameters test 
2 Turns ratio test 
3 Ratio and phase error test 
4 Polarity mark check 
5 Winding resistance measurement 
6 Secondary loop burden measurement 
7 Error line curve test for protection CT 
8 Transient CT parameters test 
9 CT nameplate guess 
*0 Saturation hysteresis loop curve measurement

Tests for Voltage Transformer:

1 Turns ratio test 
2 Ratio error and phase angle error test 
3 Polarity test 
4 Secondary burden test 
5 Winding resistance test

 

Application

 

CT PT Tester application 
1 CT nameplate check 
2 CT parameters check in work burden 
3 CT transient parameters analysis 
4 CT ratio and phase error calibration 
5 PT routine test

 

Technical index

 

1 Test standards: IEC******1, IEC******6, IEC******2, IEC******5, C*7.*3 
2 Power supply: AC**0V±*0%, *0/*0Hz±*0% 
3 Voltage output: 0.1~**0V (AC) 
4 Current output: 0.**1~5A(RMS) 
5 Power output: **0VA 
6 Maximum knee voltage measurement: *5KV 
7 Current measurement: 
  Range: 0~*0A (automatically change range in 0.1/0.4/2/*0A)  
  Error: <±0.1%*0.*1%FS <br /> 8 Voltage measurement: 
  Range: 0~**0V (automatically change range in 1V/*0V/*0V/**0V) 
  Error: < ±0.1%*0.*1%FS 
9 Turns ratio measurement: 
  Range:1~****0 
  1~***0     error<0.*5% <br />   ***0~***0  error<0.1% <br />   ***0~****0  error<0.2% <br /> *0 Phase measurement: error: ±2min; resolution: 0.*1min 
*1 Winding resistance measurement:  
   Range: 0~8kΩ (automatically change range in 2ohm/*0ohm/*0ohm/**0ohm/8kohm) 
   Error: < 0.2%RDG*0.*2%FS 
   Maximum resolution: 0.1mΩ 
*2 Temperature measurement:**0~**0 Celsius degree; error<3 Celsius degree <br /> *3 CT Secondary burden: 
   Range: 0~**0ohm (automatically change range in 2ohm/*0ohm/*0ohm/**0ohm) 
   Error: <0.2%RDG*0.*2%FS  <br />    Maximum resolution: 0.**1ohm 
*4 PT Secondary burden: 
   Range: 0~*0kohm (automatically change range in **0ohm/8kohm/*0kohm) 
   Error :<0.2%RDG*0.*2%FS  <br />    Maximum resolution: 0.1ohm 
*5 PT ratio measurement: 
   Range: 1~****0 
   1~****0 error<0.1% <br />    ****0~****0 error<0.2% <br /> *6 PT ratio error measurement: Typical error <0.*5%, Maximum Error<0.1% <br /> *7 PT phase angle measurement: maximum error < 3min 
*8 Make evaluation for test results according to selected standards 
*9 Make word report for test result 
*0 Make word reports one time for multi-group test records on the PC 
*1 Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test 
*2 Compare excitation curves with saved excitation curves in the same window 
*3 Memory capacity: >***0 groups test results  
*4 Working condition: temperature: **0℃~*0℃; moist: ≤*0% 