يبدو أنك لست عضوًا في TradeKey.com بعد. اشترك الآن للتواصل مع أكثر من 7 مليون مستورد ومصدر عالميًا.
انضم الآن ، مجانًا |
BOOK A CALL
Book Call On Your Favorite Time
Code
🗘

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
Mobile Transformer For YB Series Cubicle Mobile Transformer Substation 3150KVA

Mobile Transformer For YB Series Cubicle Mobile Transformer Substation 3150KVA

2000 ~ 50000 / Unit ( Negotiable )

|

Minimum Order

Place of Origin:

-

Price for Minimum Order:

Minimum Order Quantity:

1 Unit

Packaging Detail:

sea worthy packing

Delivery Time:

1-3 months

Supplying Ability:

5000 Unit per Year

Payment Type:

T/T, L/C

الاتصال الآن
عضو مجاني

الشخص الذي يمكن الاتصال به Ms. Daisy

Room 2702-2703,No.218 West Tianmu Road,Shanghai, Shanghai, Shanghai

الاتصال الآن

Description

Specifications  

 

YB Series Cubicle Substation 

serialization ,modularization , multiple functions , complete facility , small volume . 

 
 
 

•Main function and Features

 

            The product consists of HV distribution unit, and LV distribution unit and is divided into HV chamber, transformer chamber and LV. The HV chamber has complete functions, it with HXGN**0 ring main unit forms the primary supply system , may be arranged into several supply modes( ring main supply, terminal supply and dual-source supply) and also may be provided with HV metering elements to meet requirements on HV metering . Model S9, S*1 and other low loss oil-immersed transformers or dry transformers else may be selected . The transformer chamber is designed to have automatic forced air cooling system and lighting system . The LV chamber can constitute user-required power supply schemes in a panel type or cabinet type structure , provide several functions (Power distribution , lighting distribution reactive power compensation , and metering of electrical power) to meet users different requirements . And facilitate supply management and improve power supply quality.

 

             The HV chamber is compact in structure and is provided with mis-operation preventive interlocking function . Each chamber has automatic and forced lighting device . In addition , all elements in HV and LV chamber are reliable in performance and easy in operation , which makes the products safe and reliable and easy in operation and maintenance.

 

              It adopts both natural ventilation and forced ventilation to each good ventilation and cooling effects. The transformer chamber and LV chamber are provided with air ducts . The blower fan has a temperature controller to automatically start and stop as per the preset temperature , thus ensuring on load running of transformer.

 

               The casing body prevents rain water and foreign matter from entrance and it is made of hot-galvanized color steel sheet or anti-rust aluminum alloy sheet and subjected to anti-corrosion treatment. It looks artistic , keeps long-term corrosion , water and dust-proof under outdoor conditions ,and prolong service life or transformer.

 

                this products have following characters : serialization ,modularization , multiple functions , complete facility , small volume , light weight and good looking . They meet the requirement of IEC***0 standard and applicable to city public distribution , street lamp power supply , as well as power consumption in industrial /mineral enterprises ,high-rises, residential areas, oil fields , jetty and site construction .

 
•Main function and Features
 

            The product consists of HV distribution unit, and LV distribution unit and is divided into HV chamber, transformer chamber and LV. The HV chamber has complete functions, it with HXGN**0 ring main unit forms the primary supply system , may be arranged into several supply modes( ring main supply, terminal supply and dual-source supply) and also may be provided with HV metering elements to meet requirements on HV metering . Model S9, S*1 and other low loss oil-immersed transformers or dry transformers else may be selected . The transformer chamber is designed to have automatic forced air cooling system and lighting system . The LV chamber can constitute user-required power supply schemes in a panel type or cabinet type structure , provide several functions (Power distribution , lighting distribution reactive power compensation , and metering of electrical power) to meet users different requirements . And facilitate supply management and improve power supply quality.

 

             The HV chamber is compact in structure and is provided with mis-operation preventive interlocking function . Each chamber has automatic and forced lighting device . In addition , all elements in HV and LV chamber are reliable in performance and easy in operation , which makes the products safe and reliable and easy in operation and maintenance.

 

              It adopts both natural ventilation and forced ventilation to each good ventilation and cooling effects. The transformer chamber and LV chamber are provided with air ducts . The blower fan has a temperature controller to automatically start and stop as per the preset temperature , thus ensuring on load running of transformer.

 

               The casing body prevents rain water and foreign matter from entrance and it is made of hot-galvanized color steel sheet or anti-rust aluminum alloy sheet and subjected to anti-corrosion treatment. It looks artistic , keeps long-term corrosion , water and dust-proof under outdoor conditions ,and prolong service life or transformer.

 

                this products have following characters : serialization ,modularization , multiple functions , complete facility , small volume , light weight and good looking . They meet the requirement of IEC***0 standard and applicable to city public distribution , street lamp power supply , as well as power consumption in industrial /mineral enterprises ,high-rises, residential areas, oil fields , jetty and site construction .

 

 

 

Main Technical Parameters






















































































 
Item Unit H.V.Unit Power Transformer

(S*1;SG(B);SC(B))
L.V.unit
Load Switch Fuse
Rated Voltage kV *2 *2 *0/0.4 0.4
Rated Power kVA ≤***0
Power Frequency Test Voltage kV/1min *2   *5 2.0  2.5
Impulse Test Voltage kV *5/*5   *5 8
Rated Current(Main Circuit) A **0      
Rated Switch Current kA *1.5
Short Circuit Switch Current kA *0      
Dynamic Current kA *0      
Noise Level dB     <*8  <*5</td>  
Protect Class Arround the cabinet face is IP*3,cover and bottom aboveIP*3

Send a direct inquiry to this supplier

إلى:

Ms. Daisy < Shenda Electrical Group Co., Ltd. >

أريد أن أعرف: