Description

Electric Blasting Cap
1.Technical Index of electric blasting cap
        Specification: Industrial No.8
        Shell outer diameter: Φ6.9mm
        Shell:Flange
        Shell length:*0~*0mm
        Leg wire: Galvanized steel, copper, copper clad steel
        Leg wire length: 2m~*0m
        Igniter element: Elastic fuse head, rigid fuse head
       Variety: Common electric blasting cap, permissible electric blasting cap 
 

2.Performance of electric blasting cap:
Item Performance
Resistance        Galvanized steel core Leg-wire ≤6.3Ω, with vibration ≤2.0Ω
 
Safety current Charging with 0.2A constant direct current for 5mins, no explosion
Minimum firing current ≤0.*5A
Firing impulse 2.0~7.9A2·ms
Series firing current  *0 pieces electric detonators are connected into series circuit, and charge with 1.2A electric current, and all detonators fire.
Initiating Power Have a lead plate test, piercing into 5mm lead plate, the hole diameter should no smaller than the out-diameter of the detonator
Tensible Force on *9.6N static tension for 1 min, no damage to sealing plug and leg-wire.
Anti-jolt property Vibrate for *0min on the jolt machine, no explosion, structure damage, short circuit, open circuit and unstable performance occurs. 
Anti static  Legwire to shell discharge with 8kv voltage, ***0pf capacitance and 0Ω series resistor, no firing.
Combustible gas safety degree When initiating a permissible electric detonator in the combustible gas of 9%, the combustible gas should not be ignited.