Description
The ultraviolet band including UVA (**0nm***0nm), UVB band
(**0nm***0nm) and UVC band (**0nm***0nm).
UVA wave band is mainly used for light curing, UV light exposure
lithography, lithography, integrated circuit industry etc..
UVC band, also known as the short wave ultraviolet sterilization.
What ultraviolet germicidal lamp issued is short ultraviolet band
UVC.
LS**5 multi probe UV radiometer, using digital probe, plug design,
instrument judge probe model intelligently. At the same time can
support a variety of UV test probe, currently supports the
following 6 kinds of UV Probes: P**4, P**7, E**5. E**5, P**5L,
P**0L
LS**5 multi probe UV Light Meter
LS**5 multi probe UV Light Meter, using digital
probe, plug in type design, instrument intelligent judgment probe
type. LS**5 support UVA probe and UVC probe.
A: LS**5 Main Body Parameter
1. Instrument Weight:about **0g
2. Main Body Size:**5mm x *2mm x *4.5mm (LXWXH)
3. Power supply: 2 AAA alkaline battery
4. Probe connection: push-and-pull (SNAP)
B: Probe Parameter
1: P**4 Probe
1) Response wavelength: **0nm***0nm; peak wavelength =
**4nm
2) Measuring range:0 - *****0 uW/cm2
3) Resolution: 0.1 μW/cm2
4) Accuracy: +/**0 %
5) Test Hole Diameter: Φ*0
6) Probe Size: Diameter *6mm xThickness *6.1mm
2:P**7 Probe
1) Response wavelength: **0nm***0nm; suitable for measure UVB light
source that peak wavelength at **7nm,**8nm,**3nm etc.
2) Measuring range:0 - *****0 uW/cm2
3) Resolution: 0.1 μW/cm2
4) Accuracy: +/**0 %
5) Test Hole Diameter: Φ*0
6) Probe Size: Diameter *6mm xThickness *6.1mm
3: P**5L Probe
1) Response wavelength:**0nm***0nm; peak wavelength =
**5nm
2) Measuring range:*******0uW/cm2
3) Accuracy: +/**0 %
4) Resolution: 0.1 uW/cm2
5) Test Hole Diameter:Φ*0
6) Probe Size: Diameter *6mm xThickness *2.2mm
4: P**0L Probe
1) Response wavelength:**0nm***0nm;λp = **5nm
2) Measuring range:*******0uW /cm2
3) Accuracy: +/**0 %
4) Resolution: 0.1 uW /cm2
5) Test Hole Diameter:Φ9.2
6) Probe Size: Diameter *6mm xThickness *4.6mm
5: E**5 Probe
1) Response wavelength:**0nm***0nm; peak wavelength =
**5nm
2) Power Measuring range:0 - ****0 mW/cm2
3) Energy Measuring range: 0 **- *****9mJ/cm2
4) Accuracy: +/**0 %
5) Resolution: 0.1 mW/cm2
6) Test Hole Diameter:Φ9.2
7) Probe Size: Diameter *6mm xThickness *4.6mm
6: E**5 Probe
1) Response wavelength:**0nm***0nm;λp = **5nm
2) Power Measuring range:******0mW/cm2
3) Energy Measuring range: 0 **- *****9mJ/cm2
4) Accuracy: +/**0 %
5) Resolution: 0.1 mW/cm2
6) Test Hole Diameter:Φ9.2
7) Probe Size: Diameter *6mm xThickness *4.6mm