Description
WAYJUN WJ*8
series 8
inputs channel Current/Voltage signal to RS**5/**2
Converter,*4 Bits AD data acquisition,CE approved
Product Selection:
WJ*8 U(A) â–¡ â–¡
Input Voltage or Current Signal Interface
U1:**5V A1:**1mA **5: output is RS***5 interface
U2:***0V A2:***0mA **2: output is RS***2 interface
U3:***5mV A3:***0mA
U4:**2.5V A4:***0mA
U5:*-±5V A5:*-±1mA
U6:*-±*0V A6:*-±*0mA
U7:*-±**0mV A7:*-±*0mA
U8:user-defined A8:user-defined
Sample 1: part No.:WJ*8 A****5 *-CH ***0mA input signal,output is
RS**5 interface
Sample 2: part No.:WJ*8 U****2 *-CH **5V input signal,output is
RS**2 interface
Sample 3: part No.:WJ*8 U****2 *-CH ***0V input signal,output is
RS**2 interface
Also you can choose 1~7 channel.
Features:
>> Eight analog signal acquisition, isolated converter
RS***5/**2 output
>> **-bit AD converter, accuracy>0.*5%
>> ***0mA/***0mA current signal or **5V/***0V voltage signal
input
>> RS***5/**2 interface can be programmed calibration
module accuracy
>> Signal input / output:***0VDC
isolation
>> Wide supply range: 8 ~ *2VDC
>> High reliability, easy programming, easy to
apply
>> Standard DIN*5 rail mounting
>> User-programmable settings module address, baud rate,
etc.
>> Support the Modbus RTU protocol
>> Low cost, small size modular design
Function Description:
WJ*8 signal isolation acquisition module can be used to measure
eight channels voltage or current signal,
1. Analog signal input
**-Bit acquisition accuracy, eight channels analog input. All
products signal input range have been calibrated. In use,
users also can program calibration easily.
About the specific current or voltage input range, please see
product selection.
2. Communication protocol
Communication Interface: one channel standard RS***5 communication
interface, or one standard RS***2
communication interface, specify when ordering.
Communication Protocols: supports two protocols, characters
protocol of the command set defined and MODBUS
RTU communication protocol. Can be programmed using the kind of
communication protocol, can be achieved with
PLC, RTU of many Brands or computer monitoring system for network
communication.
Data Format: *0 Bits. 1 start bit,8 data bits,1 stop bit.
Address: (0 to **5) and baud rate (***0,***0,***0,***0,****0,****0
bps) can be set, the most long-distance
about communication networks is up to ***0 meters, through the
twisted-pair shielded cable.
Communication interface of high anti-jamming design, ± *5KV ESD
protection, communication response time is less
than **0mS.
General *:*/*
(*@*********************4VDC)
Input type: current / voltage input
Accuracy: 0.*5%
Temperature drift:± *0 ppm / ℃ (± *0 ppm / ℃, maximum)
Input Resistance: *0Ω (***0mA/***0mA/*- ± *0mA current input)
**0Ω (***0mA/*- ± *0mA current input)
1KΩ (**1mA/*- ± 1mA current input)
>**0K(5V/*0V voltage input)
>1MΩ(below 2.5V voltage input)
Bandwidth: *3 dB *0 Hz
Conversion rate: *0 Sps
Common Mode Rejection (CMR): **0 dB (1kΩ Source Imbalance