يبدو أنك لست عضوًا في TradeKey.com بعد. اشترك الآن للتواصل مع أكثر من 7 مليون مستورد ومصدر عالميًا.
انضم الآن ، مجانًا |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
OPT Hair Removal Machine

OPT Hair Removal Machine

1420 ~ 2000 / Set ( Negotiable )

|

Minimum Order

Place of Origin:

-

Price for Minimum Order:

Minimum Order Quantity:

1 Set

Packaging Detail:

Each in paper package inter and wood package outer

Delivery Time:

Within 5-7 working days after payment

Supplying Ability:

5000 Unit per Month

Payment Type:

T/T, L/C, Western Union, Money Gram, PayPal, Other

الاتصال الآن
عضو مجاني

الشخص الذي يمكن الاتصال به Ivy

Rm.200,building D,No.2801,Huangpu East RD., Guangzhou, Guangdong

الاتصال الآن

Description

1.Theory
OPT pulsed light principle is that: intense pulsed light produces light and heat effect and photochemical effects on the skin, the deep collagen and elastic fiber skin rearrange and restore skin elasticity, while enhance the vascular tissue functions, eliminate facial skin wrinkles and reduce pore shrink; additionally, intense pulsed light can also penetrate the skin, are preferentially absorbed by the pigment group and vascular tissue selectivity; Without destroying the normal skin, blood coagulation, pigment group and pigment cells are destroyed, decomposition, so as to achieve therapeutic effect of telangiectasia and pigmentation.
 
OPT medical cosmetic treatment combines ipl, 808nm diode laser and nd: yag laser 3 kinds of standard technology together. So, OPT is a highly effective skin rejuvenation, permanent hair removal, wrinkle spot removers, improve venous curve, telangiectasia and other purposes cosmetic laser system.
  
OPT is the use of cutting-edge intense pulsed light technology, belongs to the fourth generation of photonic technology. Perfect OPT (Optimal Pulse Technology) core technology, the use of three-dimensional technology concepts: energy + Pulse Width + pulse waveform.  Due to changes the pattern of treatment light output, intense pulsed light is a revolutionary in the development, not only greatly improve the efficacy but also safety.

2.How to use the OPT(SHR)  ?
 â… ã€Clinic operation】
A. Before treatment
To the machine:
b). Input enough water and make good water circulation before actual operation
c). Water source: distilled water or pure water
d). Before the operation, make sure probe cold. Then its able to start the operation. (if take operation under the state of no water circulation or hot probe, the handpiece is easy to damaged.)
e). Inflammable and explosive things should be kept away from operating room, such as stupefacient,liquid and gas.
To the patients:
a). Classification of skin: it\'s safe and effective to the white, brown or yellow skin.
b). Clean skin to eliminate the perfume and cosmetics.
c). Use digital camera for memory, take photo from different orientations, if necessary
d). If necessary, use external anesthetic one hour before the treatment; Please shave hair firstly under hair removal treatment.
f). Spread the cooling gel on skin, about 2 mm thickness
g). Wear eyepatch before actual option
Note: can not look at the intensive pulsed light directly, or alarm to peoples eyes, such as keratitis, cornea brushing off, or even lose sight.
h). forbidden to wear watch and necklace etc. during the treatment.
To the operators:
a). Adjust the right parameters
b). Touch the "image" on the LCD to start
c). Test the device working, please shot the 3 first pulse to ground at beginning,  make sure even energy output in treatment.
d). Wear glasses before actual option
e). forbidden to wear watch and necklace etc. during the treatment.
f). can not look at the intensive pulsed light directly, or alarm to peoples eyes, such as keratitis,cornea brushing off, or even lose sight.
g). Please do not optionally open the panel of the machine even power stopped, in case high voltage danger.
h). It must tighten up the screw caps of machine before movement.
i). vertically slide the probe on skin, and keep close to skin
J). Keep the machine rest every 2‐3 hours continuously working
k). The handle is fragile, please keep special care when hanging to the holder or in handle
l). Please do treatment from the lower energy at the beginning, and adjust the energy according to actual conditions.

If the probe is not cold or it even becomes hot, please stop using this machine and turn to us for help. Otherwise it will hurt people and damage the machine.

Please do not press the button on handle one press by one press or step the foot pedal step by step. That will make skin gets different energies which will sure hurt the customer.

3.Taboos
a) Pregnant 
b) Isolation in the sun
c) Sensitive to light or medicine, or are taking medicine that sensitive to light
d) Using vitamin within 6 months 
e) Not representative naevi or malignant pathological changes in the treatment area.
f) Pacemaker or quiver dispelling device user 
g) Herpes or trauma
h) Pimple record 
i) People who accept Hirudin etc. treatment (should stop using it before 2 weeks).
j) Severe diabetes patient, high blood pressure sufferer, and epileptic

Send a direct inquiry to this supplier

إلى:

Ivy < Guangzhou Niansheng Beauty Equipment Co. >

أريد أن أعرف: