يبدو أنك لست عضوًا في TradeKey.com بعد. اشترك الآن للتواصل مع أكثر من 7 مليون مستورد ومصدر عالميًا.
انضم الآن ، مجانًا |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
Medical isolated power system

Medical isolated power system

10 ~ 15000 / Piece ( Negotiable )

|

Minimum Order

Place of Origin:

-

Price for Minimum Order:

Minimum Order Quantity:

10 Piece

Packaging Detail:

in wooden cases

Delivery Time:

2 weeks

Supplying Ability:

5000 Piece per Month

Payment Type:

T/T

الاتصال الآن
عضو مجاني

الشخص الذي يمكن الاتصال به Ms. becky

Shajing, Shenzhen, Guangdong

الاتصال الآن

Description

Medical isolated power system(containing isolation transformer, insulation monitor, special sensor, *4V special power supply and remote alarm terminal) is mainly used in operating room, ICU, CCU and other critical places of hospital.
 
In the special environment of hospital, leakage current poses a potential danger to the patients. So special and strict requirements are made for electrical safety design, especially in the vitally important places like surgical operating room, ICU, CCU and so on, which all need to be equipped with medical IT power system(also called medical isolated power supply), in order to provide a safe and reliable power supply for the medical appliances within the area and ensure the safety of patients.

All the charged conductors within the protected area of IT power system are isolated from ground to prevent the dangerous current on the line insulation layer from causing micro electric shocks. The insulation monitor must be used with the isolation transformer to continuously surveil the resistance and current between the charged conductor at the secondary side of isolation transformer and earth.


Technical parameters:
1. Rated power: 6.3KVA, 8KVA, *0KVA
2. Power supply: AC**0 ± *0% (**0 V ±5%)
3. Frequency: *0 Hz - *0 Hz
4. Insulation resistance measuring range: *-**9 KΩ
5. Temperature measuring range**0 â„ƒ - **0℃
6. Storage temperature: - *0℃- *5℃
7. Voltage measuring range: *-***0VAC
8. Current measuring range: ****9A
9. Load set range: ****0%
*0. Alarm: user defined
11. Alarm output: built-in buzzer and output port
12. Other alarms: panel indicator light alarm indication
13. Alarm output contact driver: 5A / **0VAC, 5A / *0VDC
*4. CE, FCC, medical grade certification