According to ISO***5 of building materials fire prevention
performance standards, this fire test machine control platform
provides independent gas analysis, including heat release rate and
other related test required for related instruments, such as
paramagnetic oxygen sensor, CO2/CO measuring instrument, He-Ni
laser smoke density measurement and control system, etc.
Full-scale room corner test methods for surface of the
article use the same principle with the cone calorimeter and SBI
testmethod thatis based on the oxygen consumption. The method is to
simulate the corner of the fire scene as a standard testconditions,
and installation of a test sample entirely according to actual use,
the test results apply only to specific sample installation, it is
one of the most reliable standard test methods. In the corner fire
test, in accordance with the requirements of ISO***5, and the
measured material mounted on the inner walls of the room (at the
top is not installed).Using propane burners as a radiation source,
the measurement of heat release rate, temperature, heat release,
flashover time, CO2 /CO and other parameters, for which the most
important is the heat release rate and the flashover time.
Standards
• ISO
***5: Large Box test surface of the product
• ISO
******1: plywood building systems Reaction to fire test
• ASTM E
***7: Standard upholstered furniture flame test method
• ASTM E
**3: Standard guidance corner combustion experiments
The test room is built by the density of **0kg / m³-A1 class fireproof material.
The internal dimensions of the room 3.6M X 2.4M X 2.4M
The gate size: 0.8M (W) X2.0M (H)
Sandbox burner with propane gas and equipped with emergency shut-off devices.
Automatic ignition system to automatically record experimental data;
Independently movabletimetto display units.
*0kV spark ignition, a cease-fire with safety devices. Fire extinguishing drainage system design.
The full scale room corner tester is equipped withstaircasefor easy maintenance exhaust pipes.
1, Gas
sampling system includes an annular sampler probe, suction pump,
particulate filter, a cold trap, exhaust valve, water filters and
CO2 filter.
2, Three filters; Minimum filtration accuracy is 0.5um.
3, Freezing cold trap; air-conditioning compressor refrigeration
systems; controlling the temperature in 0 ~ 5ºC.
4, Suction pump,Flowrate is *3L/min,vacuumis **0mmHg, and pressure
is 2.5 bar.
5, Drying cylinder, whichfilterthe water and impurities.
6, The flow controller to control the inspiratoryair flow.
7, The sampler has *2 holes and gas flow in the opposite direction,
these holds built-in dust filter and **5mm from hoods.
8, Paramagnetic oxygen analyzer, the range is ***5%; linear
response; imports Britain Servomex oxygen sensor.
Smoke system
1, 0.5W
HE-NE laser source.
2, Thorlabs optically detector.
3,Motor driven 5 class automatically calibration device with of 0%,
*5%, *0%, *5%, **0% transmittance filters.
4,One touch calibration system in software with digital and curve
display.
1, *6bit
data acquisition module.
2, Digital
communication between computer and DAQ module.
3, Labview
based application software on DAQ and data analysis.
Operating system
1,
Labview based application system,easilyand precise to operate and
control.
2, Test status, calibration status display on screen.
3, Device status are displayed on screen and indicators
onpanel.
4, Transducers data, process parameters, test result displayed
onscreenvia digital and curve.
5, Test and calibration procedure auto executed by PLC program.
6, Device can be controlled via bothapplicationscreen and control
panel.
7, PC and PLC communicate with digital protocol which is safe and
robust.
Technical Specifications
1,Paramagn eticoxygen analyzer, the concentration range is 0~*5%,
an oxygen analyzer islinearresponse, Britain Servomex oxygen
sensor; *0% to *0% response time of less than *2s; output noise
does not exceed *0ppm;Reproduce the measured values lower than
**0ppm,
2, Infrared CO2 analyzer range: 0 to *0%;accuracyof ± 0.*1%;
3, The compressor works: cold trap: 0 to 5 degrees;
4, Import diaphragm pump, flow rate: *3 l / min
5, The standard detector color accuracy ± 5%, output linearity
(transmission) <1%, absolute permeability <1%;
Test Data
1, Heat
Release Rate (HRR),
2, Total Heat Release (THR),
3, Efficiency Heat Release (EHR),
4, Smoke Production Rate (SPR),
5, Time to Ignite (TTI),
6, Time to flameout,
7, Oxygen Consumption Rate,
8, CO2 Production Rate,
9, CO Production Rate(optional)
Size | *1,**5(W)x4,**0(D)x4,**0(H)mm |
Console Size | **0(W)×**0(D)×***0(H)mm |
Power supply | AC **0V, *0/*0Hz, *5A (control), AC **0V, *0Hz, *0A(drive) |
Weight | About 7,**0kg(Cabinet), **0kg(Control panel) |
Instructions | Provided |
Exhaust | Minimum 3.5m2/s(Measuring), Minimum**0m2/min(Exhaust) |
Other requirements | CO(0.8%)/CO2(8%), Compressed gas, Vacuum cleaners, Computers, Propane gas, Heptane gas, Nitrogen |