FOB Price
أحصل على آخر سعر( Negotiable )
|Minimum Order
Place of Origin:
-
Price for Minimum Order:
-
Minimum Order Quantity:
1 Set
Packaging Detail:
Plywood case
Delivery Time:
60 days
Supplying Ability:
100 Set per Month
Payment Type:
T/T, L/C, D/A, D/P, Western Union, Money Gram
الشخص الذي يمكن الاتصال به Sean
Chongqing, Chongqing
Introduction
Hard to catch fire and having the ability to prevent or delay the spread of flame ,wire and cable can generally refers to IEC******3 test.This wire and cable fire-resistant impact test equipment is designed according to IEC *******2 and BS***7 ****3 standard. It is used to test if the circuit will maintain integrity under flame temperature is not lower than **0ºC, and the case of a certain impact vibration. You can test cables A, B, C, D retardant properties.
Standards
• IEC
****1 part *2 test wires and cables under fire conditions - at
least at **0 ºC shocks combustion circuit integrity -
• IEC
****1 part *1 procedures and requirements for fire with shock -
rated voltage up to 0.6 / 1.0 KV cables
• IEC
****1 part 1 specifies the test method for cables which
are required to maintain circuit integrity when subject to fire and
mechanical shock under specified conditions.
•
(Option)BS********3
-The
impact is applied for the fire, the flame temperature is not lower
than **0ËšC, the rated voltage is greater than or equal to 0.6 /
1kV cable, the overall diameter of more than *0 mm
• IEC
******2
-The
impact is applied for the fire, the flame temperature is not lower
than **0ËšC, the rated voltage is greater than or equal to 0.6 /
1kV cable, the overall diameter of not more than *0 mm;
Main
Features
Control cabinet
parameters:
1,
This Fire Resistance with Mechanical Shock and Water
Spray Test Equipment is installed with dual flow meters
and pressure regulators.
2, The
test equipment can automatically control the testing
process.
3,
Intelligent detection function, when a short circuit in the sample
during the test, automatic alarm and turn off the heat
source.
4,
Display: touch screen display temperature curve
5, Timer:
0 to 9 hours *9 minutes *9 seconds
6, Control
Box Size: **0 (D) X**0 (W) X***0 (H)
7, Load: 0
~ **0V test voltage is adjustable;
8, Load
current range: 0.1 ~ 3A, test current can be adjusted standards,
but more than 3A is protected;
9, Load
capacity should be able to ensure the test current approaches 3A
can still ensure the test to continue testing. Also apply to spray
test and hammering test load requirement
Fire test equipment
requirements
1, The
burner nozzle length **0mm, width *5mm, there are three holes on
the nozzle opening troubleshooting, pore radius of 1.*2 mm pitch is
3.2 mm. And this Fire Resistance with Mechanical Shock
and Water Spray Test Equipment is equipped with Venturi
mixer;
2,
Installation and testing of the cable ladder fastened to the
supporting steel chassis; the testing process can be adjusted on
both sides of the vertical component testing ladder depending on
cable size requirements (test stand length: ***0mm, height: *0mm,
total weight: *8 ± 1kg)
Metal ring
inside diameter of about: **0 mm.
3, The
test equipment has a temperature measuring device (diameter less
than 2mm K-type thermocouple, from the flame ports
*5mm).
The front
burner torch from the bottom of the box less than **0MM, **0MM and
from the tank wall at least.According to the test
grade, the flame temperature is adjustable: **0 ~ ***0 ° (A grade
**0 °, B grade **0 °, C, D grade **0 °)
4, The
horizontal distance between the center of the burner test cable
****0MM, the vertical axis from the longitudinal axis of the
specimen cable burner ******0MM
5, Provide
standards of five inner diameter of about **0 mm from metal rings,
metal ring distance can be freely adjusted to facilitate sample
fixed hold.
6,
Stainless steel sample tray, load *0kg
Mechanical Shock Test
Equipment
1,
Stainless steel bracket impact structure; box painting
processing;
2,
Independent motor control box hit;
3, Thump
cone is ¢ *5, and length is **0mm.
4,
Pounding free fall from angle of *0 ° to thump.
5, The
motor drived rod hammer hammer striking as standard required
period.
6,
Hammering cycle (time): *0 ± 2S / time;
7, Total
time test: 0 ~ ****9S
8, The
ribbon burner (as sprinkler test) (shared with refractory
combustion test bench)
9, A test
temperature of **0 ~ ***0 ° (A grade **0 °, B grade **0 °, C, D
grade **0 °)
*0,
Thermocouple diameter is less than ¢ 2mm. (Shared with refractory
combustion test bench)
*1, Each
phase of cable through 0.*5A of current test.
Water Spray Test
Equipment
1, Use
propane or natural gas burner, using integrated long **0mm ribbon
burner.
2,
Combustion test temperature **0 ± *0 °.
3, With a
diameter of not more than ¢ 2 of the thermocouple.
4,
Sprinkler water pressure is **0 ~ **0Kpa, to test the water is
about 0.*5 ~ 0.3L / S.m2.
5, Test
test length of about **0mm.
6, Test test cable when powered by an isolation transformer, and is connected to the 3A fuse or circuit breaker, as well as each phase of the cable off lights indication.
Technical Specification
Size |
1,**0(W)×**0(D)×1,**0(H)mm |
Console Size |
**0(W)×**0(D)×1,**0(H)mm |
Power |
AC **0V *-phase, *0/*0Hz, *0A |
Weight |
**0kg |
Exhaust |
Minimum *5m³/ min |
Auxiliary |
Vacuum cleaners, compressed gas, propane gas |