TP********0 **0 pairs MDF terminal block is used on the vertical
side of the MDF, which is used for the termination between external
lines and jumper wires. It adopts the IDC connection methods. It
consists of *0 pieces *-pair modules. Our TP******5 protection
magazine can be inserted into the block, with the function of
protecting personnel and equipments against over voltage.
Modular design and installations
Technical
Parameters
1) Working temperature: **0℃ ~ *0℃
2) Storage temperature: **5℃ ~*5℃
3) Relative humidity: ≤*5%(**0℃)
4) Atmospheric pressure: *0kPa ~**6kPa
5) Appearance: the color of all metal and plastic parts is uniform,
without any scratch, rust, crusting and cracks.
6) The labels are clear, complete and durable.
7) Insulation resistance: under normal ambient conditions, after
high temperature test, low temperature test, temperature varying
test and humidity heat test, the insulation resistance between any
two independent contacts, and/or between contacts and metal parts
≥ ***0MΩ
8) Contact resistance between contacts: under normal ambient
conditions, the contact resistance between contacts ≤7 mΩ. After
high temperature test, low temperature test, temperature varying
test and humidity heat test, the increasing resistance ≤3
mΩ And after inserting the connection cord (or test cord)
into the module for **0 times, the increasing resistance ≤3
mΩ
9) Contact resistance between conductor and contact: under normal
ambient conditions, the contact resistance between contacts ≤3
mΩ. After high temperature test, low temperature test, temperature
varying test and humidity heat test, the increasing resistance ≤2
mΩ. And after terminating for **0 times, the increasing resistance
≤2 mΩ.
*0) Dielectric strength: under normal ambient conditions, after
high temperature test, low temperature test, temperature varying
test and humidity heat test, the insulation resistance between any
two independent contacts, and/or between contacts and metal parts
is able to withstand an AC voltage of ***0V (virtual value) at
*5Hz~*0Hz sinowave for 1 minute, without spark over and flying
arc
*1) Gas tight performance: contact touches the conductor at both
sides, and thus forming the gas tight area, while the area of gas
tight occupies ≥*0% of the touched area on each side.
*2) Conductor diameter range: 0.*2mm*0.6mm, while insulation ≤
1.4mm
*3) Pulling strength:≥*5N while pulling from the vertical side of
the contacts
*4) Flame retardant performance: all plastic parts are flame
retardant, reaching grade of UL FV0
*5) Life circle: ≥**0 times
Order
Data
ITEM NO |
UNIT |
DESCRIPTIONS |
TP********0 |
pcs |
**0 pairs MDF terminal block,
without protection |
TP******2TM |
pcs |
*-pole test cord, with test plug to 6P2C
modular plug for MDF terminal block #TP********0, 3m |
TP******2TA |
pcs |
*-pole test cord, with test plug to
alligator clip for MDF terminal block #TP********0, 3m |
TP******4TA |
pcs |
*-pole test cord, with test plug to
alligator clip for MDF terminal block #TP********0, 3m |
TP******1DP |
pcs |
1 pair disconnection plug for MDF
terminal block # TP********0 |