سعر فوب
أحصل على آخر سعر( Negotiable )
|1 Set Minimum Order
بلد:
China
نموذج رقم:
SPX-100/150/250B-Z
سعر فوب:
( Negotiable )أحصل على آخر سعر
الموقع:
-
سعر الحد الأدنى للطلب:
-
الحد الأدني للطلب:
1 Set
تفاصيل التغليف:
box
موعد التسليم:
-
القدرة على التوريد:
100 Set per Week
نوع الدفع:
T/T
مجموعة المنتج :
-
الشخص الذي يمكن الاتصال به Ms. Yang
Unit 305 1st Building,No.2101 Wu ning Road,Shanghai,China, Shanghai, Shanghai
â… Summary
SPX Model biochemical Incubator is a high precision incubator
with heating andcooling controlled. It is applicable for the
plant cultivating, testing of seed breeding,cultivating and
storing the bacteria, mould and microorganism, analyzing water
and BODmensuration. It is applicable in biologic descendiblity
project, medical college, sanitationepidemic prevention, medicine
testing, farming and fisheries institutes for research.
â…¡ Structure Feature
The body is made of high quality steel plate, the outer paint
coating is firm andartistic. The double insulating glass
observation window is equipped on the door. You canobserve
clearly. Interior chamber with four arcual corners is made of
mirror stainlesssteel sheet, so that the temperature uniformity
in chamber is good, and the equipmentwears well, and it is easy
to clean.Temperature control part adopts singlechip technology
advanced type intelligentdigital display temperature controller.
User can set and adjust temperature and time byoperating touch
s on control panel according to the different requirements
to reachthe aim of experiment.
â…¢ Principle of Operation
Biochemical incubator transforms the actual temperature felt by
temperature sensorin chamber to electrical signal, and control
the work of heater and compressor bymicrocomputer to reach the
required temperature.
â…£ Technical Parameter
1. Volume: **0, **0L, **0L;2. Temp. range: 5~*0℃;3. Temp.
floctuation: ±1℃(**0L, **0L), ±1.5℃(**0L);4. Temp.
uniformity: ±1.5℃(**0L, **0L), ±2℃(**0L);5. Power supply: AC
**0V/*0HZ;6. Power consumption: **0W(**0L), **0W(**0, **0L);7.
Work ambient: Ambient temp.:*0~*0℃; Relative humidity ≤*0%;8.
Refrigerant: R*2;9. Equipment class: Sort I Model B.â…¤
Installation1. Install the equipment indoor where is ventilated
and dry and has no direct sunlight.The equipment should be placed
at a distance from the wall above *0cm.
2. Adjust the incubator with adjusting screws on the bottom to
make it stable.3. The equipment uses AC**0V/*0Hz power supply.
Power supply circuit must havereliable earth wire to ensure the
safe use.
â…¥ Method of Use
~1. Connect the power supply and turn on the power switch, and
setting of temperatureand time can be operated at this time.2.
Temp./Time is used for switch temperature and time1)
Temperature set: press Temp./Time , temperature set
indicate light will beon, press Set and enter SV state, a
digit in set display screen will flash, pressMove (<) to
move the flashing digit to you need, then press ∨ or ∧ to
changetemperature set value to you need (min. is 0.1℃), press
Set to save the set value.The left screen displays
measured temperature, the right screen displays set
temperature.2) Time set: press Temp./Time , time set
indicate light will be on, press Set and enter TV state, a
digit in set display screen will flash, press Move (<)to
move the flashing digit to you need, then press ∨ or ∧ to change
time set value toyou need (min. is 1h), press Set to save
the set value. The left screen displaysmeasured time, the right
screen displays set time.Timing function: timing function starts
after the equipment works. Output will beclosed after timing
ends. Heater and compressor stop work, and temperature in
chamberwill reach ambient temperature gradually.3. State
indicate: the equipment will run accord with set parameters after
set is finished.When measured temperature is lower than set
temperature, the equipment enter theheating state, and heating
indicate light will be on. When measured temperature is
higherthan set temperature, the equipment enter the refrigeration
state, and refrigerationindicate light will be on. When measured
temperatuer is higher than set temperature over 4℃, alarm
indicate light will be on with buzzer beeps.4. Parameters
amending: if temperature and time parameters need amended
whenequipment running, follow step 1 and step 2.5. Rapid set:
when set parameters, press ∧ to increase set value, keep
the pressed for 3 sec to increase the set value
continuously. Press ∨ to decrease setvalue, keep the
pressed for 3 sec to decrease the set value
continuously.â…¦ Notice and Maintenance1. When convey incubator,
keep upright or horizontal less than *5 degrees.2. Don’t change
the setting value continually in use to avoid over loading
occurred bycontinual startup of compressor and affect the use
life of the equipment.3. When illumination is unnecessary, you
should place the illumination switch to “close”to avoid effect
the upper temperature, and extend the use life of luminous
tube.4. The equipment is installed two groups of fuse. If
malfunction occurs when running,please cut off the power first
and check the fuse, then check other parts.5. Don’t wipe the
outer with corrosive solution to keep the equipment clean. Wipe
theinner with dry cloth or alcohol to keep the inner clean.6.
Keep the inner chamber dry and cut off the power when the
equipment is not in use.7. Check frequently whether the screw
type ventilator inner is in normal operation toensure the
temperature uniformity inner. Don’t place items too closely in
chamber andblock the uptake of fan when testing to make for air
circulation in chamber.8. Don’t touch and collide the temperature
sensing probe to cause the temperature out ofcontrol.9. When
malfunction occurs, user should not overhaul arbitrarily, but
invite aprofessional to maintain or contact our department of
sale.*0. Our products practise “Three guarantees”. From the date
of sold, we will maintain theequipment free if any quality
problem within one year (except artificially damaged). Ifexceed
the period of “Three guarantees”, we will charge repairs fee as
appropriate.
بلد: | China |
نموذج رقم: | SPX-100/150/250B-Z |
سعر فوب: | ( Negotiable ) أحصل على آخر سعر |
الموقع: | - |
سعر الحد الأدنى للطلب: | - |
الحد الأدني للطلب: | 1 Set |
تفاصيل التغليف: | box |
موعد التسليم: | - |
القدرة على التوريد: | 100 Set per Week |
نوع الدفع: | T/T |
مجموعة المنتج : | - |