يبدو أنك لست عضوًا في TradeKey.com بعد. اشترك الآن للتواصل مع أكثر من 7 مليون مستورد ومصدر عالميًا. انضم الآن ، مجانًا |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
SC037 Russia Federation Regulation Milk Antibiotics Beta-lactams and Tetracyclines Rapid Test Kit SC037 Russia Federation Regulation Milk Antibiotics Beta-lactams and Tetracyclines Rapid Test Kit SC037 Russia Federation Regulation Milk Antibiotics Beta-lactams and Tetracyclines Rapid Test Kit SC037 Russia Federation Regulation Milk Antibiotics Beta-lactams and Tetracyclines Rapid Test Kit SC037 Russia Federation Regulation Milk Antibiotics Beta-lactams and Tetracyclines Rapid Test Kit
Next

SC037 Russia Federation Regulation Milk Antibiotics Beta-lactams and Tetracyclines Rapid Test Kit

70 ~ 85 USD / Box ( Negotiable )

|

1 Box Minimum Order

بلد:

China

نموذج رقم:

SC060

سعر فوب:

70 ~ 85 USD / Box ( Negotiable ) أحصل على آخر سعر

الموقع:

China

سعر الحد الأدنى للطلب:

70 per Box

الحد الأدني للطلب:

1 Box

تفاصيل التغليف:

carton

موعد التسليم:

3 days for ready goods

القدرة على التوريد:

9000 Piece per Month

نوع الدفع:

T/T, L/C, D/A, D/P, Western Union, Money Gram, PayPal

مجموعة المنتج :

الاتصال الآن
عضو مجاني

الشخص الذي يمكن الاتصال به LUKE

Shaanxi

الاتصال الآن

مواصفات المنتج

  • Classification: rapid test kit
  • Brand Name: Watarbio
  • Detection Time:8min(3min+5min)
  • Detection Limit:1.5-80ppb
  • Detection Temp:45℃
  • Storage:2-8℃
  • Matrix:Cow/goat milk
  • Instrument:Dry Incubator
  • Shelf Life:12 Months

الوصف

PRINCIPLE
The WatarBio DairyPal® BT is competitive test involving two receptors in one single operation, the -lactams and Tetracyclines in the raw milk sample compete for the antibody with the antigen coated on the membrane of the test dipstick. Then after a color reaction, when the sample is free of the analytes, a stronger colour density development occurs at the specific capture lines, indicating the presence of the concerned analytes in the milk sample. On the contrary, the presence of the analytes in the sample will not cause the stronger coloured signal at the specific capture lines.
APPLICATIONS
The WatarBio DairyPal® BT is a rapid test that detect simultaneously the presence of the -lactams and Tetracyclines molecules in a raw cow milk sample.
CONTENTS
*2 tubes each with 1 strip of 8 reagent microwells and 8 dipsticks.
1 Microwell holder
1 Kit insert
**0pcs Disposable plastic pipette,
INSTRUMENT MAY NEEDED BUT NOT PROVIDED
DairyPal® Dry incubator(Model: Mini-B)
DairyPal® Dipstick Reader (Model: TSR***0A, OPTIONAL)
TEST PROCEDURE
1.Read the instruction attentively, choose a clean and dry place to perform the test, wash and dry your hands before starting.
2.Take the kit out of the fridge and wait until the temperature of the reagents reaches the ambient temperature.
3.Calculate how many milk sample will be tested and mark the sample tubes to identify. The milk samples should be fully liquid without any clots or deposition, the ideal temperature of milk sample is between 4 to *0℃.
4.Take the tubes required from the kit package, take out as many micro-wells and dipsticks as the milk samples to be tested, and make proper marks to match the milk sample.
To open a dipsticks tube, press the safety ring down, take off the ring and get the tube cap off with your thumb.
Recover the cap tightly after taking out the required micro-wells and dipsticks.
Empty one test tube then open another one.
Keep the unused micro-well caps tightly sealed. Do NOT tear off the strip of 8 microwell caps.
Use the exposed dipsticks in 1 hour.
5.Preheat the Dry Incubator(suggest to use DairyPal Mini-B Dry Incubator) to *5℃.
6.Place the required numbers of the mircrowells in the dry incubator, transfer **0ul of the milk samples into the microwells, inject and reject the milk sample for 5 times consecutively to homogenize the lyophilized reagent and milk sample.
Dip the end of the plastic pipette(DairyPal Mini pipette) tips into the milk and slowly releases the sucker.
When the sucker is back into its initial position, transfer the **0µl of milk into the reagents, by slowly pushing the sucker down to the bottom.
7.Start the timer to incubate for 3 minutes at *5℃;
During the incubation, The receptors will detect the presence of the antibiotics in the milk sample. The reaction will take 3 minutes.
8.Dip the dipsticks into the micro-wells with the "Sample End" down side to the bottom.
9.Start the timer to incubate for 5 minutes at *5℃ again.
*0. Then take out the dipsticks and place them laterally in a dry clean place, peel off the sample pad, interpret the result.
Use a clean nipper(or new pipette tip) to scrape gently and slowly the sample pad.
The peeling off of the sample pad will stop the ongoing reaction of the receptors.
File the used sample pad peeled off dipsticks if necessary.
RESULTS INTERPRETATION
The dipsticks are embodied with 3 lines, Control line, -lactams Line and Tetracyclines Line, which are briefly expressed as CTL, B and T. The test results will be determined by the color presence of the lines. The following diagram describes the result identification.
NEGATIVE: Line CTL is visible, Line B and Line T are both stronger than or equal to Line CTL, which means that, the milk sample contains fewer -lactams and Tetracyclines than value given in the table.
-lactams POSITIVE: Line CTL is visible, Line B is weaker than Line CTL, Line T is stronger than Line CTL, which means that the milk sample contains the -lactams more than the value in the table, the Tetracyclines fewer that the value in the table.
Tetracyclines POSITIVE: Line CTL is visible, Line T is weaker than Line CTL, Line B is stronger than Line CTL; which means that the milk sample contains the Tetracyclines more than the value in the table, the -lactams fewer that the value in the table.
FULL POSITIVE: Line CTL is visible; either Line B or Line T is weaker than Line CTL; which means that the milk sample contains the the -lactams and Tetracyclines both more than the value in the table.
REMARKS: Control line is used as a quality indicator, which will always appear regardless of the line B/T. If Control line does NOT appear, it indicates that the result is INVALID. Users please check the kit insert again and re-do the assay with new test dipsticks.
SPECIFICITY
The test has no cross reaction with the clenbuterol, ractopamine, salbutamol, melamine, trenbolone, sulfonamides, chloramphenicol, macrolides.
STORAGE
**8℃ in cool dark place, do not freeze. The kit will be valid in *2 months. The lot number and expired date are printed on the package.
PRECAUTIONS
Do the assay following the instruction, do NOT touch the membrane of the dipstick.
Seal the bottle after taking out required dipsticks.
The dipstick is used for only once; Do NOT use it repeatedly.
The positive result should be further confirmed.

بلد: China
نموذج رقم: SC060
سعر فوب: 70 ~ 85 / Box ( Negotiable ) أحصل على آخر سعر
الموقع: China
سعر الحد الأدنى للطلب: 70 per Box
الحد الأدني للطلب: 1 Box
تفاصيل التغليف: carton
موعد التسليم: 3 days for ready goods
القدرة على التوريد: 9000 Piece per Month
نوع الدفع: T/T, L/C, D/A, D/P, Western Union, Money Gram, PayPal
مجموعة المنتج : 2in1

Send a direct inquiry to this supplier

إلى:

LUKE < Shaanxi Watar Biotechnology Co., Ltd. >

أريد أن أعرف: